Published by 1. Bartłomiej GARDA, 2. Karol BEDNARZ, AGH University of KrakowORCID: 1. 0000-0001-6150-5617; 2. 0009-0007-6857-4851 Abstract. The objective outlined in the paper is to conduct reliable measurement tests on memristor behavior in three-phase systems. Memristors, acting as nonlinear elements, exhibit intriguing phenomena within such systems. Various configurations, including Delta and Wye connections with threeContinue reading “Testing the SDC memristors in Three Phase Systems”
Tag Archives: Load Flow Analysis / Power Flow Analysis
Selecting An Inverter for a PV Micro-Installation
Published by Konrad SEKLECKI, Leszek S. LITZBARSKI, Marek OLESZ, Emanuel GIFUNI, Grzegorz REDLARSKI, Jacek GROCHOWSKI Abstract. The article describes recommendations related to the optimal selection of inverters for PV micro-installations. It presents different types of inverters used in PV installations depending on their type and power. Regardless of the case, attention should be paid toContinue reading “Selecting An Inverter for a PV Micro-Installation”
Automated Power Factor Correction Through Microcontroller in Energy Sector
Published by 1. Pawan Kumar PANDEY1, 2. Ramesh KUMAR2, 3. Manish SINGLA2,3, 4. Sergey KOKIN4, 5. Murodbek SAFARALIEV4, 6. Javod AHYOEV3, Gyan Ganga Institute of Technology and Sciences (1), Chitkara University Institute of Engineering and Technology (2), Applied Science Private University (3), Ural Federal University (4), Tajik Technical University Named After Academician M.S. Osimi (5)ORCID:Continue reading “Automated Power Factor Correction Through Microcontroller in Energy Sector”
PV Fed Boost Converter Efficiency Improvement using Neural Networks and Model Predictive Control
Published by 1. Kheira MELOUK1, 2. Mohamed DELLA KRACHAI1, 3. Saidia DELLA KRACHAI2, Faculty of Electrical Engineering, Department of Automatics, University of Science and Technology of Oran. U.S.T.O.M.B (1), Spatial Development Center, Algeria (2)ORCID: 1. 0000-0002-9300-649X; 2. 0000-0002-0899-8923; 3. 0000-0002-0710-1037 Abstract. This paper presents a model predictive control (MPC) technique applied to a DC-DC boostContinue reading “PV Fed Boost Converter Efficiency Improvement using Neural Networks and Model Predictive Control”
Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network
Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and Technology. ORCID: 0000-0002-1628-1818 Abstract. Receivers such as power electronic devices, due to their widespread use and non-linear characteristics, are the most common cause of poor quality electricity. The share of non-linear receivers in the overall balance of power installed at a single customer increased to theContinue reading “Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network”
Impact of Climatic Factors on the Restoration Time of MV Power Lines
Published by1. Kornelia A. BANASIK, 2. Andrzej Ł. CHOJNACKI, Kielce University of Technology, Chair of Power Engineering, Power Electronics and Electrical MachinesORCID: 1. 0000-0002-6629-8650, 2. 0000-0002-9227-7538 Abstract. The duration of outages (restoration time) is a fundamental parameter characterizing the extent of failures, as well as the quality of organisation during their elimination. Its understanding allowsContinue reading “Impact of Climatic Factors on the Restoration Time of MV Power Lines”
Interference Present in the Electrical Installation with Special Consideration of Higher Harmonics
Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and Technology. ORCID: 0000-0002-1628-1818 Abstract. Converter devices, i.e. computer power supplies prevalent in buildings, as well as LED light sources, which have replaced traditional light bulbs due to their widespread use and characteristics, are the most common cause of poor power quality. The construction of the devicesContinue reading “Interference Present in the Electrical Installation with Special Consideration of Higher Harmonics”
Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid
Published by 1. Aleksander CHUDY1, 2. Paweł MAZUREK1, 3. Korneliusz PAWLAK2, Lublin University of Technology (1), Ball Packaging Europe Lublin Sp. z o.o. (2) ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. In the present study, power quality parameters across two residential blocks, a single-family house, and an industrial facility were studied and evaluated. Compliance was generallyContinue reading “Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid”
Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems
Published by 1. Ali Boukerche1, 2. Salima Lekhchine1, 3. Tahar Bahi2, Department of Mechanical Engineering, Faculty of technology, University of 20 August 1955, LGMM Laboratory, Skikda, Algeria (1), Department of Electrical Engineering,Faculty of technology, Badji Mokhtar University, Laboratory (LASA) , Annaba, Algeria (2) E-mail: a.boukerche@univ-skikda.dz Abstract. At present, energy saving and renewable energies represent oneContinue reading “Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems”
The Measurement of Power Consumed by an Industrial Robot under Dynamic States
Published by Krzysztof OLESIAK, Czestochowa University of Technology ORCID: 0000-0003-4552-7810 Abstract. The paper presents a method of measuring power consumed by an industrial robot in a single phase system. A computer-based measurement set was constructed, consisting of special purpose voltage and current converters and a PC with a multi-channel measuring card. Measurements were conducted andContinue reading “The Measurement of Power Consumed by an Industrial Robot under Dynamic States”