Developing an Expert System for Analyzing Defects on Production Lines

Published by 1. Krzysztof KRÓL1,2, 2. Grzegorz KŁOSOWSKI1,2, 3. Monika KULISZ3, 4. Arkadiusz MAŁEK2, Research and Development Center, Netrix S.A, Lublin (1), WSEI University, Lublin (2), Lublin University of Technology (3) ORCID:1. 0000-0002-0114-2794; 2. 0000-0001-7927-3674; 3. 0000-0002-8111-2316, 4. 0000-0001-7772-2755 Abstract. This article will introduce the concept of analyzing and detecting defects on production lines, payingContinue reading “Developing an Expert System for Analyzing Defects on Production Lines”

Connecting European devices in the US

Published by Krzysztof BOLEK1, Mirosław CZECHOWSKI2, Tymoteusz NACZYŃSKI3, Politechnika Krakowska (1), Politechnika Krakowska (2), Politechnika Krakowska (3),ORCID: 1. 10009-0005-4756-8327.; 2. 0000-0001-5093-4870; 3. 0000-0003-0323-5393 Abstract. This article describes the concept of building an inexpensive power supply for testing devices in Poland whose destination is the USA. Firstly, the power grid configurations used in the USA isContinue reading “Connecting European devices in the US”

Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study

Published by Dranetz Technologies, Inc. Website: Dranetz.com  SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failures by installingContinue reading “Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study”

Power Quality Lessons from an Controlled Environment Agriculture Facility

Published by Dranetz Technologies, Inc. Website: Dranetz.com  For controlled environment agriculture (CEA) operations, temperature, humidity, airflow, lighting, and CO₂ must stay within narrow limits 24/7 to foster growing conditions for high-value crops. When power quality deteriorates, environmental systems can go off-spec, putting these crops at risk. When HVAC and VFDs began failing unexpectedly, New Jersey CEAContinue reading “Power Quality Lessons from an Controlled Environment Agriculture Facility”

Simulated Blockchain-Enabled Peer-to-Peer Energy Trading in Marketplace

Published by Saheed Lekan GBADAMOSI1,2, Nnamdi I. NWULU1, Center for Cyber Physical Food, Energy and Water Systems, University of Johannesburg, Auckland Park 2006, South Africa (1), Department of Electrical and Electronic Engineering, Bowen University Iwo, Osun State, Nigeria (2)ORCID: 0000-0001-7398-813 Abstract. This study examines the use of Ethereum-based smart contracts to facilitate peer-to-peer energy tradingContinue reading “Simulated Blockchain-Enabled Peer-to-Peer Energy Trading in Marketplace”

Multicore Underground Power Line Health Monitoring using Optical Fiber Bragg Grating

Published by M Hazwan WAHAB1,2, Mohammad Syuhaimi AB RAHMAN2, Ahmad Asrul IBRAHIM2, A H AHMAD ABAS1,2, Norhidayah AHMAD1,2, Quest International University (1), University Kebangsaan Malaysia (2) Abstract. Fiber Bragg grating (FBG) is a relatively novel method used for network health monitoring that has a number of advantages including high accuracy, multiplexing, electromagnetic interference resistance andContinue reading “Multicore Underground Power Line Health Monitoring using Optical Fiber Bragg Grating”

Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN

Published by Sri SUWASTI, Yiyin KLISTAFANI, Muhammad Ruswandi DJALAL, State Polytechnic of Ujung Pandang Abstract. The objective of this research is to develop a water cylinder filling pump integrated with a hybrid solar and grid (PLN) system. The performance of the pump is calculated to enable a comparative analysis with the energy and economic aspectsContinue reading “Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN”

Optimizing Electrical Energy Savings by Utilizing Refrigerant Catalysts in Compressors

Published by 1. Idris KUSUMA1, 2. R. RULIYANTA2, 3. Diah WIDIASTUTI, 4. Mohammad FATHONIUniversitas Nasional (1, 2, 3), Institut Teknologi Budi Utomo (4)ORCID: 1.0009-0006-1808-2229; 2.0000-0002-2439-330X; 4.0009.0006.6439.5699 Abstract. Even though the government of the Republic of Indonesia has banned the use of R22, it is still widely found in industry. The problem is that the industryContinue reading “Optimizing Electrical Energy Savings by Utilizing Refrigerant Catalysts in Compressors”

Current Harmonic Emission of On-Board Electric Vehicle Chargers

Published by Aleksander CHUDY, Department of Electrical Engineering and Electrotechnology, Faculty of Electrical Engineering and Computer Science Lublin University of Technology, ORCID: 0000-0002-3183-8450 Abstract. The case of study were 7 on-board EV chargers. The majority of current harmonics emission measurements during light-duty EVs charging took place in private garages of single-family houses in the LublinContinue reading “Current Harmonic Emission of On-Board Electric Vehicle Chargers”

Power Quality Inc. is Proud to Exhibit at the EPRI Power Quality Applications (PQA) Conference and Exhibition 2026!

Intelligent Power Quality for a Changing Grid: June 2-3, 2026, Charlotte, North Carolina, EPRI Charlotte Office & Conference Center, 1300 West W. T. Harris Blvd, Charlotte, NC, 28262, US Join us June 2–3 in Charlotte, NC to connect with power quality professionals focused on real‑world solutions. We provide power quality consulting, engineering services, training, and specialized tools to helpContinue reading “Power Quality Inc. is Proud to Exhibit at the EPRI Power Quality Applications (PQA) Conference and Exhibition 2026!”