Selecting An Inverter for a PV Micro-Installation

Published by Konrad SEKLECKI, Leszek S. LITZBARSKI, Marek OLESZ, Emanuel GIFUNI, Grzegorz REDLARSKI, Jacek GROCHOWSKI Abstract. The article describes recommendations related to the optimal selection of inverters for PV micro-installations. It presents different types of inverters used in PV installations depending on their type and power. Regardless of the case, attention should be paid toContinue reading “Selecting An Inverter for a PV Micro-Installation”

PV Fed Boost Converter Efficiency Improvement using Neural Networks and Model Predictive Control

Published by 1. Kheira MELOUK1, 2. Mohamed DELLA KRACHAI1, 3. Saidia DELLA KRACHAI2, Faculty of Electrical Engineering, Department of Automatics, University of Science and Technology of Oran. U.S.T.O.M.B (1), Spatial Development Center, Algeria (2)ORCID: 1. 0000-0002-9300-649X; 2. 0000-0002-0899-8923; 3. 0000-0002-0710-1037 Abstract. This paper presents a model predictive control (MPC) technique applied to a DC-DC boostContinue reading “PV Fed Boost Converter Efficiency Improvement using Neural Networks and Model Predictive Control”

Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems

Published by 1. Ali Boukerche1, 2. Salima Lekhchine1, 3. Tahar Bahi2, Department of Mechanical Engineering, Faculty of technology, University of 20 August 1955, LGMM Laboratory, Skikda, Algeria (1), Department of Electrical Engineering,Faculty of technology, Badji Mokhtar University, Laboratory (LASA) , Annaba, Algeria (2) E-mail: a.boukerche@univ-skikda.dz Abstract. At present, energy saving and renewable energies represent oneContinue reading “Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems”

Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN

Published by Sri SUWASTI, Yiyin KLISTAFANI, Muhammad Ruswandi DJALAL, State Polytechnic of Ujung Pandang Abstract. The objective of this research is to develop a water cylinder filling pump integrated with a hybrid solar and grid (PLN) system. The performance of the pump is calculated to enable a comparative analysis with the energy and economic aspectsContinue reading “Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN”

Improving Energy Output and Efficiency of PV Installations using Bifacial Panels in Public Facilities

Published by 1. Jacek KUSZNIER, 2. Marcin SULKOWSKI, 3. Gabriela Druć, Bialystok University of Technology, Faculty of Electrical Engineering ORCID: 1. 0000-0001-8436-5717; 2. 0000-0002-3079-314X Abstract. The issue of improving the energy efficiency of photovoltaic installations is very important due to the limited location options in public facilities. Therefore, this paper presents the possibilities of improvingContinue reading “Improving Energy Output and Efficiency of PV Installations using Bifacial Panels in Public Facilities”

Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network

Published by Wiktoria GRYCAN, Wroclaw University of Science and Technology, ORCID: 0000-0001-8121-7612 Abstract. Prosumerism is inherently designed to be a tool that alleviates the grid. Still, not every prosumer aligns the consumption profile with the energy generation profile in photovoltaic installations. Therefore, the rapid development of Renewable Energy Sources (RES) in Poland, especially photovoltaic installations,Continue reading “Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network”

Efficient High Voltage Gain Simplified DC-DC Converter for Enhanced Solar Power Harvesting

Published by Shanmugavadivu Natarajan, Department of Electrical and Electronics Engineering, Sri Venkateswara College of Engineering, Sriperumbudur, 602117, India Abstract. This study introduces a novel transformerless high voltage gain DC-DC converter for solar power. It combines a two-inductor boost converter, voltage multiplier, and switched capacitor cells, achieving a remarkable high voltage gain with 98.24% efficiency. AContinue reading “Efficient High Voltage Gain Simplified DC-DC Converter for Enhanced Solar Power Harvesting”

Power Flow Analysis of Distributed Generation and Distributed Storage (DGDC) in DC Microgrid Using Newton Raphson Method

Published by Machmud Effendy1, Dandy Dwi Saputra1,Fourys Yudo Setiawan Paisey2,Department of Electrical Engineering,University of Muhammadiyah Malang, Indonesia (1)Department of Electrical Engineering, University of Papua Manokwari, Indonesia (2) Abstract. Centralized generation centralized storage architecture (CGCSA) and distributed generation distributed storage architecture (DGDSA) are two operation of the proposed scheme, both architectures are evaluated at different distributionContinue reading “Power Flow Analysis of Distributed Generation and Distributed Storage (DGDC) in DC Microgrid Using Newton Raphson Method”

Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources

Published by Ruchika, D.K. Jain, DCRUST, Murthal, Haryana Abstract. Battery energy storage system (BESS) plays a dominant role in large scale penetration of renewable energy sources into the grid. They help in a better match between the demand- supply during standalone mode and the grid connected mode. In this paper, the authors proposed a newContinue reading “Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources”

Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems

Published by 1. Piotr GRYGIEL1,2, 2. Jan TARŁOWSKI2, 3. Krzysztof MIK3, Gdańsk University of Technology (1), Xdisc S.A.,Warsaw, Poland (2), Energy Conversion and Renewable Resources Research Centre, Polish Academy of Sciences, (3) ORCID: 1. 0000-0003-2769-9088; 3. 0000-0002-9510-3066 Abstract. Two types of full-size photovoltaic modules for on-grid systems with maximum DC voltage of 600 V haveContinue reading “Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems”