Automated Power Factor Correction Through Microcontroller in Energy Sector

Published by 1. Pawan Kumar PANDEY1, 2. Ramesh KUMAR2, 3. Manish SINGLA2,3, 4. Sergey KOKIN4, 5. Murodbek SAFARALIEV4, 6. Javod AHYOEV3, Gyan Ganga Institute of Technology and Sciences (1), Chitkara University Institute of Engineering and Technology (2), Applied Science Private University (3), Ural Federal University (4), Tajik Technical University Named After Academician M.S. Osimi (5)ORCID:Continue reading “Automated Power Factor Correction Through Microcontroller in Energy Sector”

Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems

Published by 1. Ali Boukerche1, 2. Salima Lekhchine1, 3. Tahar Bahi2, Department of Mechanical Engineering, Faculty of technology, University of 20 August 1955, LGMM Laboratory, Skikda, Algeria (1), Department of Electrical Engineering,Faculty of technology, Badji Mokhtar University, Laboratory (LASA) , Annaba, Algeria (2) E-mail: a.boukerche@univ-skikda.dz Abstract. At present, energy saving and renewable energies represent oneContinue reading “Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems”

The Measurement of Power Consumed by an Industrial Robot under Dynamic States

Published by Krzysztof OLESIAK, Czestochowa University of Technology ORCID: 0000-0003-4552-7810 Abstract. The paper presents a method of measuring power consumed by an industrial robot in a single phase system. A computer-based measurement set was constructed, consisting of special purpose voltage and current converters and a PC with a multi-channel measuring card. Measurements were conducted andContinue reading “The Measurement of Power Consumed by an Industrial Robot under Dynamic States”

Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study

Published by Dranetz Technologies, Inc. Website: Dranetz.com  SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failures by installingContinue reading “Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study”

Simulated Blockchain-Enabled Peer-to-Peer Energy Trading in Marketplace

Published by Saheed Lekan GBADAMOSI1,2, Nnamdi I. NWULU1, Center for Cyber Physical Food, Energy and Water Systems, University of Johannesburg, Auckland Park 2006, South Africa (1), Department of Electrical and Electronic Engineering, Bowen University Iwo, Osun State, Nigeria (2)ORCID: 0000-0001-7398-813 Abstract. This study examines the use of Ethereum-based smart contracts to facilitate peer-to-peer energy tradingContinue reading “Simulated Blockchain-Enabled Peer-to-Peer Energy Trading in Marketplace”

Optimizing Electrical Energy Savings by Utilizing Refrigerant Catalysts in Compressors

Published by 1. Idris KUSUMA1, 2. R. RULIYANTA2, 3. Diah WIDIASTUTI, 4. Mohammad FATHONIUniversitas Nasional (1, 2, 3), Institut Teknologi Budi Utomo (4)ORCID: 1.0009-0006-1808-2229; 2.0000-0002-2439-330X; 4.0009.0006.6439.5699 Abstract. Even though the government of the Republic of Indonesia has banned the use of R22, it is still widely found in industry. The problem is that the industryContinue reading “Optimizing Electrical Energy Savings by Utilizing Refrigerant Catalysts in Compressors”

A VECM Analysis of the Impact of Economic Growth and Investment on Electricity Consumption in Indonesia

Published by Andi Abdul Halik LATEKO1, Yusri Syam AKIL2, Universitas Muhammadiyah Makassar (1), Hasanuddin University (2) ORCID: 1. https://orcid.org/0000-0002-9002-131X Abstract. This paper employs a Vector Error Correction Model (VECM) analysis to investigate the influence of economic growth (GDP) and investment (FDI) on electricity consumption (EPC) in Indonesia. By examining annual data from 1971-2019, the studyContinue reading “A VECM Analysis of the Impact of Economic Growth and Investment on Electricity Consumption in Indonesia”

Overview of Edge Computing Applications in Energy Sector

Published by Olga Pilipczuk, University of Szczecin ORCID: 0000-0001-7078-2544 Abstract. Currently, edge computing supports many solutions in the energy industry and has attracted the research interest of many researchers. The edge computing concept is relatively novel, the first impactful works were noticed in 2014-2015 years. Thus, there is a lack of studies summarizing the researchContinue reading “Overview of Edge Computing Applications in Energy Sector”

Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study

Published by Dranetz Technologies, Inc., Technical Documents – Application Note SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failuresContinue reading “Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study”

Thermodynamic Modelling of Waste to Energy Power Plant: A Case Study in Makassar City, Indonesia

Published by 1.Nur HAMZAH, 2.Suryanto SURYANTO, 3.Muhammad ANSHAR, 4.Firman FIRMAN, 5. Muhammad Ruswandi DJALAL, 6. Muhammad Alif AL AFGAN. State Polytechnic of Ujung Pandang ORCID: 1. 0000-0002-7114-2247 Abstract. Waste is a major problem in big cities in Indonesia, one of which is Makassar City. Every year the amount of waste generated by the residents ofContinue reading “Thermodynamic Modelling of Waste to Energy Power Plant: A Case Study in Makassar City, Indonesia”