Published by Dranetz Technologies, Inc. Website: Dranetz.com For controlled environment agriculture (CEA) operations, temperature, humidity, airflow, lighting, and CO₂ must stay within narrow limits 24/7 to foster growing conditions for high-value crops. When power quality deteriorates, environmental systems can go off-spec, putting these crops at risk. When HVAC and VFDs began failing unexpectedly, New Jersey CEAContinue reading “Power Quality Lessons from an Controlled Environment Agriculture Facility”
Tag Archives: AFE/VFD
Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study
Published by Dranetz Technologies, Inc., Technical Documents – Application Note SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failuresContinue reading “Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study”
What are non-linear loads and why are they a concern today?
Published by Mirus International Inc., [2010-01-08] MIRUS-FAQ001-B2, FAQ’s Harmonic Mitigating Transformers, 31 Sun Pac Blvd., Brampton, Ontario, Canada. L6S 5P6. A load is considered non-linear if its impedance changes with the applied voltage. The changing impedance means that the current drawn by the non-linear load will not be sinusoidal even when it is connected toContinue reading “What are non-linear loads and why are they a concern today?”
Harmonics & Waveform Measurements Low Pass Filter & Sine Wave Filter for a 460V 100HP AC Motor with VFD
Published by Dranetz™ Technologies, Inc., Case Study, Website: dranetz.com. This case study was submitted by Ing. Leopoldo Martínez Basulto, Dranetz México. INTRODUCTION Harmonics are an important PQ issue today. Variable Frequency Drives (VFD), Uninterruptible Power Systems (UPS), computers, LED lighting, electronic ballasts, etc. are widely used in all kinds of facilities. It is well knownContinue reading “Harmonics & Waveform Measurements Low Pass Filter & Sine Wave Filter for a 460V 100HP AC Motor with VFD”
Advantages of 6-Pulse VFD with Lineator AUHF vs Active Front End (AFE) Drives
White Paper (August 20th, 2015) Published by Anthony (Tony) Hoevenaars, P. Eng , President and CEO Mirus International Inc. INTRODUCTION Active Front End (AFE) Drive manufacturers will claim that their technology provides the best solution for treatment of harmonics associated with variable frequency drives (VFDs). They are quick to point out benefits over standard 6-PulseContinue reading “Advantages of 6-Pulse VFD with Lineator AUHF vs Active Front End (AFE) Drives”