Selecting An Inverter for a PV Micro-Installation

Published by Konrad SEKLECKI, Leszek S. LITZBARSKI, Marek OLESZ, Emanuel GIFUNI, Grzegorz REDLARSKI, Jacek GROCHOWSKI Abstract. The article describes recommendations related to the optimal selection of inverters for PV micro-installations. It presents different types of inverters used in PV installations depending on their type and power. Regardless of the case, attention should be paid toContinue reading “Selecting An Inverter for a PV Micro-Installation”

Blockchain Technology and Peer-to-Peer Energy Trading

Published by Anna ZIELIŃSKA, AGH University of Science and Technology, Faculty of Management Abstract: The article describes new legal regulations in Poland and the EU, which are to introduce the possibility of peer-to-peer trading in electricity. The text presents the possibility of using blockchain technology for this purpose. It describes how blockchain can revolutionize theContinue reading “Blockchain Technology and Peer-to-Peer Energy Trading”

Interference Present in the Electrical Installation with Special Consideration of Higher Harmonics

Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and Technology. ORCID: 0000-0002-1628-1818 Abstract. Converter devices, i.e. computer power supplies prevalent in buildings, as well as LED light sources, which have replaced traditional light bulbs due to their widespread use and characteristics, are the most common cause of poor power quality. The construction of the devicesContinue reading “Interference Present in the Electrical Installation with Special Consideration of Higher Harmonics”

Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems

Published by 1. Ali Boukerche1, 2. Salima Lekhchine1, 3. Tahar Bahi2, Department of Mechanical Engineering, Faculty of technology, University of 20 August 1955, LGMM Laboratory, Skikda, Algeria (1), Department of Electrical Engineering,Faculty of technology, Badji Mokhtar University, Laboratory (LASA) , Annaba, Algeria (2) E-mail: a.boukerche@univ-skikda.dz Abstract. At present, energy saving and renewable energies represent oneContinue reading “Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems”

Connecting European devices in the US

Published by Krzysztof BOLEK1, Mirosław CZECHOWSKI2, Tymoteusz NACZYŃSKI3, Politechnika Krakowska (1), Politechnika Krakowska (2), Politechnika Krakowska (3),ORCID: 1. 10009-0005-4756-8327.; 2. 0000-0001-5093-4870; 3. 0000-0003-0323-5393 Abstract. This article describes the concept of building an inexpensive power supply for testing devices in Poland whose destination is the USA. Firstly, the power grid configurations used in the USA isContinue reading “Connecting European devices in the US”

Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study

Published by Dranetz Technologies, Inc. Website: Dranetz.com  SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failures by installingContinue reading “Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study”

Simulated Blockchain-Enabled Peer-to-Peer Energy Trading in Marketplace

Published by Saheed Lekan GBADAMOSI1,2, Nnamdi I. NWULU1, Center for Cyber Physical Food, Energy and Water Systems, University of Johannesburg, Auckland Park 2006, South Africa (1), Department of Electrical and Electronic Engineering, Bowen University Iwo, Osun State, Nigeria (2)ORCID: 0000-0001-7398-813 Abstract. This study examines the use of Ethereum-based smart contracts to facilitate peer-to-peer energy tradingContinue reading “Simulated Blockchain-Enabled Peer-to-Peer Energy Trading in Marketplace”

Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN

Published by Sri SUWASTI, Yiyin KLISTAFANI, Muhammad Ruswandi DJALAL, State Polytechnic of Ujung Pandang Abstract. The objective of this research is to develop a water cylinder filling pump integrated with a hybrid solar and grid (PLN) system. The performance of the pump is calculated to enable a comparative analysis with the energy and economic aspectsContinue reading “Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN”

Design of a Protection System for Distributed Energy Sources in Distribution Grids

Published by 1. Róbert Štefko1, 2. Michal Kolcun1, 3. Marek Bobček1, 4. Damian Mazur2 , 5. Bogdan Kwiatkowski2, Technical University of Košice (1), Rzeszow University of Technology (2) ORCID: 1. 0000-0002-2477-4559, 2. 0000-0002-8041-9076, 3. 0009-0004-1912-211X; 4. 0000-0002-3247-5903, 5. 0000-0001-5287-2191 Abstract. The continuous rise in electricity consumption and the integration of renewable energy sources into distributionContinue reading “Design of a Protection System for Distributed Energy Sources in Distribution Grids”

Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study

Published by Dranetz Technologies, Inc., Technical Documents – Application Note SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failuresContinue reading “Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study”