Selecting An Inverter for a PV Micro-Installation

Published by Konrad SEKLECKI, Leszek S. LITZBARSKI, Marek OLESZ, Emanuel GIFUNI, Grzegorz REDLARSKI, Jacek GROCHOWSKI Abstract. The article describes recommendations related to the optimal selection of inverters for PV micro-installations. It presents different types of inverters used in PV installations depending on their type and power. Regardless of the case, attention should be paid toContinue reading “Selecting An Inverter for a PV Micro-Installation”

PV Fed Boost Converter Efficiency Improvement using Neural Networks and Model Predictive Control

Published by 1. Kheira MELOUK1, 2. Mohamed DELLA KRACHAI1, 3. Saidia DELLA KRACHAI2, Faculty of Electrical Engineering, Department of Automatics, University of Science and Technology of Oran. U.S.T.O.M.B (1), Spatial Development Center, Algeria (2)ORCID: 1. 0000-0002-9300-649X; 2. 0000-0002-0899-8923; 3. 0000-0002-0710-1037 Abstract. This paper presents a model predictive control (MPC) technique applied to a DC-DC boostContinue reading “PV Fed Boost Converter Efficiency Improvement using Neural Networks and Model Predictive Control”

Blockchain Technology and Peer-to-Peer Energy Trading

Published by Anna ZIELIŃSKA, AGH University of Science and Technology, Faculty of Management Abstract: The article describes new legal regulations in Poland and the EU, which are to introduce the possibility of peer-to-peer trading in electricity. The text presents the possibility of using blockchain technology for this purpose. It describes how blockchain can revolutionize theContinue reading “Blockchain Technology and Peer-to-Peer Energy Trading”

Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid

Published by 1. Aleksander CHUDY1, 2. Paweł MAZUREK1, 3. Korneliusz PAWLAK2, Lublin University of Technology (1), Ball Packaging Europe Lublin Sp. z o.o. (2) ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. In the present study, power quality parameters across two residential blocks, a single-family house, and an industrial facility were studied and evaluated. Compliance was generallyContinue reading “Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid”

Connecting European devices in the US

Published by Krzysztof BOLEK1, Mirosław CZECHOWSKI2, Tymoteusz NACZYŃSKI3, Politechnika Krakowska (1), Politechnika Krakowska (2), Politechnika Krakowska (3),ORCID: 1. 10009-0005-4756-8327.; 2. 0000-0001-5093-4870; 3. 0000-0003-0323-5393 Abstract. This article describes the concept of building an inexpensive power supply for testing devices in Poland whose destination is the USA. Firstly, the power grid configurations used in the USA isContinue reading “Connecting European devices in the US”

Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study

Published by Dranetz Technologies, Inc. Website: Dranetz.com  SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failures by installingContinue reading “Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study”

Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN

Published by Sri SUWASTI, Yiyin KLISTAFANI, Muhammad Ruswandi DJALAL, State Polytechnic of Ujung Pandang Abstract. The objective of this research is to develop a water cylinder filling pump integrated with a hybrid solar and grid (PLN) system. The performance of the pump is calculated to enable a comparative analysis with the energy and economic aspectsContinue reading “Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN”

Design of a Protection System for Distributed Energy Sources in Distribution Grids

Published by 1. Róbert Štefko1, 2. Michal Kolcun1, 3. Marek Bobček1, 4. Damian Mazur2 , 5. Bogdan Kwiatkowski2, Technical University of Košice (1), Rzeszow University of Technology (2) ORCID: 1. 0000-0002-2477-4559, 2. 0000-0002-8041-9076, 3. 0009-0004-1912-211X; 4. 0000-0002-3247-5903, 5. 0000-0001-5287-2191 Abstract. The continuous rise in electricity consumption and the integration of renewable energy sources into distributionContinue reading “Design of a Protection System for Distributed Energy Sources in Distribution Grids”

Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study

Published by Dranetz Technologies, Inc., Technical Documents – Application Note SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failuresContinue reading “Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study”

A Hybrid Approach for Enhancing Grid Restoration

Published by Minaxi1, Sanju Saini2, Garima Tiwari3, Deenbandhu Chhotu Ram University of Science and Technology, Murthal ORCID: 1. 0000-0003-4172-725X; 2. 0000-0003-1390-4861; 3. 0000-0002-3004-0375 Abstract. Blackout restoration is crucial to energy security and infrastructure resilience. Black-start procedures must be used to restore a power grid methodically. Grid recovery requires selecting the correct unit black-start optimization methods.Continue reading “A Hybrid Approach for Enhancing Grid Restoration”