Published by Anna ZIELIŃSKA, AGH University of Science and Technology, Faculty of Management Abstract: The article describes new legal regulations in Poland and the EU, which are to introduce the possibility of peer-to-peer trading in electricity. The text presents the possibility of using blockchain technology for this purpose. It describes how blockchain can revolutionize theContinue reading “Blockchain Technology and Peer-to-Peer Energy Trading”
Tag Archives: energy-efficiency
Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems
Published by 1. Ali Boukerche1, 2. Salima Lekhchine1, 3. Tahar Bahi2, Department of Mechanical Engineering, Faculty of technology, University of 20 August 1955, LGMM Laboratory, Skikda, Algeria (1), Department of Electrical Engineering,Faculty of technology, Badji Mokhtar University, Laboratory (LASA) , Annaba, Algeria (2) E-mail: a.boukerche@univ-skikda.dz Abstract. At present, energy saving and renewable energies represent oneContinue reading “Recommendation for a Structure and Fuzzy Logic Control of a Common Storage System between Autonomous Photovoltaic Systems”
Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study
Published by Dranetz Technologies, Inc. Website: Dranetz.com SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failures by installingContinue reading “Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study”
Simulated Blockchain-Enabled Peer-to-Peer Energy Trading in Marketplace
Published by Saheed Lekan GBADAMOSI1,2, Nnamdi I. NWULU1, Center for Cyber Physical Food, Energy and Water Systems, University of Johannesburg, Auckland Park 2006, South Africa (1), Department of Electrical and Electronic Engineering, Bowen University Iwo, Osun State, Nigeria (2)ORCID: 0000-0001-7398-813 Abstract. This study examines the use of Ethereum-based smart contracts to facilitate peer-to-peer energy tradingContinue reading “Simulated Blockchain-Enabled Peer-to-Peer Energy Trading in Marketplace”
Design of a Protection System for Distributed Energy Sources in Distribution Grids
Published by 1. Róbert Štefko1, 2. Michal Kolcun1, 3. Marek Bobček1, 4. Damian Mazur2 , 5. Bogdan Kwiatkowski2, Technical University of Košice (1), Rzeszow University of Technology (2) ORCID: 1. 0000-0002-2477-4559, 2. 0000-0002-8041-9076, 3. 0009-0004-1912-211X; 4. 0000-0002-3247-5903, 5. 0000-0001-5287-2191 Abstract. The continuous rise in electricity consumption and the integration of renewable energy sources into distributionContinue reading “Design of a Protection System for Distributed Energy Sources in Distribution Grids”
Analysis of Electrical Generators for Wind Electric Installations
Published by Aliashraf BAKHTIYAROV1, Gulshan ABDULLAYEVA2, Hamid PIRIYEV3, Azerbaijan State Oil and Industry University ORCID: 2. 0000-0003-0168-9623; 3. 0009-0000-2992-6358 Abstract. In today’s world, when the role of renewable energy sources is becoming increasingly important in the context of combating climate change and reducing dependence on fossil fuels, wind energy occupies a leading position. Wind turbinesContinue reading “Analysis of Electrical Generators for Wind Electric Installations”
Thermodynamic Modelling of Waste to Energy Power Plant: A Case Study in Makassar City, Indonesia
Published by 1.Nur HAMZAH, 2.Suryanto SURYANTO, 3.Muhammad ANSHAR, 4.Firman FIRMAN, 5. Muhammad Ruswandi DJALAL, 6. Muhammad Alif AL AFGAN. State Polytechnic of Ujung Pandang ORCID: 1. 0000-0002-7114-2247 Abstract. Waste is a major problem in big cities in Indonesia, one of which is Makassar City. Every year the amount of waste generated by the residents ofContinue reading “Thermodynamic Modelling of Waste to Energy Power Plant: A Case Study in Makassar City, Indonesia”
An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant
Published by Jacek KOZYRA1, Zbigniew ŁUKASIK1, Aldona KUŚMIŃSKA-FIJAŁKOWSKA1, Piotr TAŃSKI2, Kazimierz Pulaski University of Radom, Faculty of Transport, Electrical Engineering and Computer Science (1) Baxtom Sp. z o.o, (2) ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031 Abstract. Poor quality of electric energy is a large problem for most of the enterprises and production plants takingContinue reading “An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant”
Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network
Published by Wiktoria GRYCAN, Wroclaw University of Science and Technology, ORCID: 0000-0001-8121-7612 Abstract. Prosumerism is inherently designed to be a tool that alleviates the grid. Still, not every prosumer aligns the consumption profile with the energy generation profile in photovoltaic installations. Therefore, the rapid development of Renewable Energy Sources (RES) in Poland, especially photovoltaic installations,Continue reading “Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network”
Some Issues of Increasing the Efficiency of Electric Machines
Published by Samira KHANAHMEDOVA, Azerbaijan State Oil and Industry UniversityORCID: 0000-0001-8862-1570 Abstract. The article discusses ways to reduce losses to increase efficiency in electric machines. The amount of energy loss is determined by the efficiency coefficient. The issues of changing the size of an electric machine under electromagnetic loads with a constant power source andContinue reading “Some Issues of Increasing the Efficiency of Electric Machines”