Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid

Published by 1. Aleksander CHUDY1, 2. Paweł MAZUREK1, 3. Korneliusz PAWLAK2, Lublin University of Technology (1), Ball Packaging Europe Lublin Sp. z o.o. (2) ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. In the present study, power quality parameters across two residential blocks, a single-family house, and an industrial facility were studied and evaluated. Compliance was generallyContinue reading “Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid”

Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study

Published by Dranetz Technologies, Inc. Website: Dranetz.com  SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failures by installingContinue reading “Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study”

Power Quality Lessons from an Controlled Environment Agriculture Facility

Published by Dranetz Technologies, Inc. Website: Dranetz.com  For controlled environment agriculture (CEA) operations, temperature, humidity, airflow, lighting, and CO₂ must stay within narrow limits 24/7 to foster growing conditions for high-value crops. When power quality deteriorates, environmental systems can go off-spec, putting these crops at risk. When HVAC and VFDs began failing unexpectedly, New Jersey CEAContinue reading “Power Quality Lessons from an Controlled Environment Agriculture Facility”

Current Harmonic Emission of On-Board Electric Vehicle Chargers

Published by Aleksander CHUDY, Department of Electrical Engineering and Electrotechnology, Faculty of Electrical Engineering and Computer Science Lublin University of Technology, ORCID: 0000-0002-3183-8450 Abstract. The case of study were 7 on-board EV chargers. The majority of current harmonics emission measurements during light-duty EVs charging took place in private garages of single-family houses in the LublinContinue reading “Current Harmonic Emission of On-Board Electric Vehicle Chargers”

Power Quality Inc. is Proud to Exhibit at the EPRI Power Quality Applications (PQA) Conference and Exhibition 2026!

Intelligent Power Quality for a Changing Grid: June 2-3, 2026, Charlotte, North Carolina, EPRI Charlotte Office & Conference Center, 1300 West W. T. Harris Blvd, Charlotte, NC, 28262, US Join us June 2–3 in Charlotte, NC to connect with power quality professionals focused on real‑world solutions. We provide power quality consulting, engineering services, training, and specialized tools to helpContinue reading “Power Quality Inc. is Proud to Exhibit at the EPRI Power Quality Applications (PQA) Conference and Exhibition 2026!”

What Makes a Power Quality Problem Worth Solving?

Published by Dranetz Technologies, Inc. Tech Tip: What Makes a Power Quality Problem Worth Solving?, Website: Dranetz.com  Most power quality events won’t shut you down. But when they do, they cost more than just a headache. The challenge isn’t detecting power quality problems. That’s the easy part. The real question is: Do those issues actually matter to your operation? AContinue reading “What Makes a Power Quality Problem Worth Solving?”

Power Quality Standards: What You Need to Know

Published by Dranetz Technologies, Inc. Tech Tip: Power Quality Standards: What You Need to Know, Website: Dranetz.com  If you’ve ever connected two different power quality meters to the same circuit and gotten different results, you’re not alone. It’s an age-old issue in power quality monitoring. And when it happens, the obvious question is: which reading should youContinue reading “Power Quality Standards: What You Need to Know”

International Standards for Power Quality Measurement Systems

Published by P Axelberg, Unipower AB, Sweden & M H. J. Bollen, Chalmers University of Technology, Sweden I. INTRODUCTION During the last decade, there has been an increasing focus on power quality (PQ). The interest and demand for quality assurance of electrical power has several fundamental causes. First of all, electrical power can be consideredContinue reading “International Standards for Power Quality Measurement Systems”

Revenue Accurate vs. Revenue Certified/Grade

Published by Dranetz Technologies, Inc., Technical Documents – White Paper INTRODUCTION In addition to our energy metering products, most Dranetz Power Quality products can also compute and measure common energy parameters such as W, VA, VAR, PF, Demand, Energy, and more. The ability to measure energy in addition to PQ opens the door to many more applications,Continue reading “Revenue Accurate vs. Revenue Certified/Grade”

An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant

Published by Jacek KOZYRA1, Zbigniew ŁUKASIK1, Aldona KUŚMIŃSKA-FIJAŁKOWSKA1, Piotr TAŃSKI2, Kazimierz Pulaski University of Radom, Faculty of Transport, Electrical Engineering and Computer Science (1) Baxtom Sp. z o.o, (2) ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031 Abstract. Poor quality of electric energy is a large problem for most of the enterprises and production plants takingContinue reading “An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant”