Published by Michael B. Marz, American Transmission Company, Waukesha, WI Email: mmarz@atcllc.com INTRODUCTION The use of sophisticated power electronics and communication systems to improve power system efficiency, flexibility and reliability is increasing interharmonic distortion and adding equipment sensitive to that distortion to the system. Knowledge of interharmonics, their sources, effects, measurement, limits and mitigation, willContinue reading “Interharmonics: What They Are, Where They Come From and What They Do”
Search results for: Interharmonics
Interharmonics: Theory and Modeling
IEEE Task Force on Harmonics Modeling and Simulation Published by A. Testa, M. F. Akram, R. Burch, G. Carpinelli, G. Chang, V. Dinavahi, C. Hatziadoniu, W. M. Grady, E. Gunther, M. Halpin, P. Lehn, Y. Liu, R. Langella, M. Lowenstein, A. Medina, T. Ortmeyer, S. Ranade, P. Ribeiro, N. Watson, J. Wikston, and W. XuContinue reading “Interharmonics: Theory and Modeling”
Defining Interharmonics
White Paper, April 2013 Contributed by Chris Mullins, VP of Engineering and Operations, Power Monitors, Inc. Email: cmullins@powermonitors.comWebsite: http://www.powermonitors.comTel: 800.296.4120 ABSTRACT Interharmonics are frequency components at noninteger harmonics of the line frequency. The proliferation of large DC-converter variable speed drives and wind/solar inverter generation has led to an increase in interharmonic levels. Troubleshooting the resultingContinue reading “Defining Interharmonics”
Power Quality – IEEE 519-2022
Published by Comsys AB, website: comsys.se, ADF Technology: Power quality – IEEE 519-2022 A commonly used and very important standard is IEEE 519-2022 (previous versions IEEE 519-1992 and IEEE 519-2014). The standard, among other things, puts two requirements on harmonics; and absolute maximum THDU level, and a variable maximum TDD level. All limits are appliedContinue reading “Power Quality – IEEE 519-2022”
Assessment of the Impact of the Micro Wind Turbine on the Power Quality in the Distribution Network
Published by Marek GAŁA, Andrzej JĄDERKO, Politechnika Częstochowska, Wydział Elektryczny Abstract. The article presents the principles of measurements and assessment of power quality characteristics, with the power supplied by the micro wind turbine connected to the distribution network. It describes the basic technical parameters of the vertical axis micro wind turbine 10 kW and theContinue reading “Assessment of the Impact of the Micro Wind Turbine on the Power Quality in the Distribution Network”
HARMONICS: Understanding the Facts – Part 1
Published by Richard P. Bingham Abstract. Understanding what is important to know about harmonics can be challenging for those without extensive electrical engineering backgrounds. In this three part series, this first article will review what a harmonic is, the second will help to clarify what those important facts are, and the third will provide detailsContinue reading “HARMONICS: Understanding the Facts – Part 1”
Harmonic, Interharmonic and Supraharmonic Characterisation of a 12 MW Wind Park Based on Field Measurements
Published by Ana Maria Blanco1, Britta Heimbach2, Bruno Wartmann2, Jan Meyer1, Marco Mangani2, Martin Oeschger2 1Institute of Electrical Power Systems and High Voltage Engineering, Technische UniversitätDresden, Dresden, Germany2Elektrizitätswerk der Stadt Zürich – EWZ, Zurich, Switzerland1E-mail: ana.blanco@tu-dresden.de 24th International Conference & Exhibition on Electricity Distribution (CIRED), 12-15 June 2017.Session 2: Power quality and electromagnetic compatibility Abstract:Continue reading “Harmonic, Interharmonic and Supraharmonic Characterisation of a 12 MW Wind Park Based on Field Measurements”
Harmonic Measurement in Electrical Networks
Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Harmonic measurement in electrical networks Procedures for harmonic measurement Harmonic measurements are carried out on industrial or commercial sites: • Preventively, to obtain an overall idea on distribution-network status (network mapping),• In view of corrective action, to determine the origin of a disturbance and determineContinue reading “Harmonic Measurement in Electrical Networks”
Assessment of the Impact of Photovoltaic System on the Power Quality in the Distribution Network
Published by Marek GAŁA, Andrzej JĄDERKO, Czestochowa University of Technology, Faculty of Electrical Engineering Abstract. The paper offers a characteristic of a photovoltaic (PV) system with the function UPS, equipped with energy storage AQUION ENERGY Battery 25 kWh and a system for monitoring and management of energy flow. Results and their analysis is presented forContinue reading “Assessment of the Impact of Photovoltaic System on the Power Quality in the Distribution Network”
The Difference Between Class A & Class S
Published by GMC-Instruments Power Quality: What Does Class A Mean? Power quality monitoring doesn’t often become an issue until incidents such as system malfunctions, equipment failures, process interruptions, data loss, IT disruptions or even power failure have occurred. As a rule, incidents of this sort are very time-consuming because they cause can’t always pinpointed rightContinue reading “The Difference Between Class A & Class S”