Published by 1. Bartłomiej GARDA, 2. Karol BEDNARZ, AGH University of KrakowORCID: 1. 0000-0001-6150-5617; 2. 0009-0007-6857-4851 Abstract. The objective outlined in the paper is to conduct reliable measurement tests on memristor behavior in three-phase systems. Memristors, acting as nonlinear elements, exhibit intriguing phenomena within such systems. Various configurations, including Delta and Wye connections with threeContinue reading “Testing the SDC memristors in Three Phase Systems”
Tag Archives: Harmonics
Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network
Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and Technology. ORCID: 0000-0002-1628-1818 Abstract. Receivers such as power electronic devices, due to their widespread use and non-linear characteristics, are the most common cause of poor quality electricity. The share of non-linear receivers in the overall balance of power installed at a single customer increased to theContinue reading “Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network”
Interference Present in the Electrical Installation with Special Consideration of Higher Harmonics
Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and Technology. ORCID: 0000-0002-1628-1818 Abstract. Converter devices, i.e. computer power supplies prevalent in buildings, as well as LED light sources, which have replaced traditional light bulbs due to their widespread use and characteristics, are the most common cause of poor power quality. The construction of the devicesContinue reading “Interference Present in the Electrical Installation with Special Consideration of Higher Harmonics”
Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid
Published by 1. Aleksander CHUDY1, 2. Paweł MAZUREK1, 3. Korneliusz PAWLAK2, Lublin University of Technology (1), Ball Packaging Europe Lublin Sp. z o.o. (2) ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. In the present study, power quality parameters across two residential blocks, a single-family house, and an industrial facility were studied and evaluated. Compliance was generallyContinue reading “Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid”
The Measurement of Power Consumed by an Industrial Robot under Dynamic States
Published by Krzysztof OLESIAK, Czestochowa University of Technology ORCID: 0000-0003-4552-7810 Abstract. The paper presents a method of measuring power consumed by an industrial robot in a single phase system. A computer-based measurement set was constructed, consisting of special purpose voltage and current converters and a PC with a multi-channel measuring card. Measurements were conducted andContinue reading “The Measurement of Power Consumed by an Industrial Robot under Dynamic States”
Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study
Published by Dranetz Technologies, Inc. Website: Dranetz.com SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failures by installingContinue reading “Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study”
Power Quality Lessons from an Controlled Environment Agriculture Facility
Published by Dranetz Technologies, Inc. Website: Dranetz.com For controlled environment agriculture (CEA) operations, temperature, humidity, airflow, lighting, and CO₂ must stay within narrow limits 24/7 to foster growing conditions for high-value crops. When power quality deteriorates, environmental systems can go off-spec, putting these crops at risk. When HVAC and VFDs began failing unexpectedly, New Jersey CEAContinue reading “Power Quality Lessons from an Controlled Environment Agriculture Facility”
Current Harmonic Emission of On-Board Electric Vehicle Chargers
Published by Aleksander CHUDY, Department of Electrical Engineering and Electrotechnology, Faculty of Electrical Engineering and Computer Science Lublin University of Technology, ORCID: 0000-0002-3183-8450 Abstract. The case of study were 7 on-board EV chargers. The majority of current harmonics emission measurements during light-duty EVs charging took place in private garages of single-family houses in the LublinContinue reading “Current Harmonic Emission of On-Board Electric Vehicle Chargers”
Power Quality Inc. is Proud to Exhibit at the EPRI Power Quality Applications (PQA) Conference and Exhibition 2026!
Intelligent Power Quality for a Changing Grid: June 2-3, 2026, Charlotte, North Carolina, EPRI Charlotte Office & Conference Center, 1300 West W. T. Harris Blvd, Charlotte, NC, 28262, US Join us June 2–3 in Charlotte, NC to connect with power quality professionals focused on real‑world solutions. We provide power quality consulting, engineering services, training, and specialized tools to helpContinue reading “Power Quality Inc. is Proud to Exhibit at the EPRI Power Quality Applications (PQA) Conference and Exhibition 2026!”
What Makes a Power Quality Problem Worth Solving?
Published by Dranetz Technologies, Inc. Tech Tip: What Makes a Power Quality Problem Worth Solving?, Website: Dranetz.com Most power quality events won’t shut you down. But when they do, they cost more than just a headache. The challenge isn’t detecting power quality problems. That’s the easy part. The real question is: Do those issues actually matter to your operation? AContinue reading “What Makes a Power Quality Problem Worth Solving?”