Published by Dranetz Technologies, Inc. Tech Tip: Power Quality Standards: What You Need to Know, Website: Dranetz.com If you’ve ever connected two different power quality meters to the same circuit and gotten different results, you’re not alone. It’s an age-old issue in power quality monitoring. And when it happens, the obvious question is: which reading should youContinue reading “Power Quality Standards: What You Need to Know”
Tag Archives: Harmonics
Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study
Published by Dranetz Technologies, Inc., Technical Documents – Application Note SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failuresContinue reading “Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study”
International Standards for Power Quality Measurement Systems
Published by P Axelberg, Unipower AB, Sweden & M H. J. Bollen, Chalmers University of Technology, Sweden I. INTRODUCTION During the last decade, there has been an increasing focus on power quality (PQ). The interest and demand for quality assurance of electrical power has several fundamental causes. First of all, electrical power can be consideredContinue reading “International Standards for Power Quality Measurement Systems”
An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant
Published by Jacek KOZYRA1, Zbigniew ŁUKASIK1, Aldona KUŚMIŃSKA-FIJAŁKOWSKA1, Piotr TAŃSKI2, Kazimierz Pulaski University of Radom, Faculty of Transport, Electrical Engineering and Computer Science (1) Baxtom Sp. z o.o, (2) ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031 Abstract. Poor quality of electric energy is a large problem for most of the enterprises and production plants takingContinue reading “An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant”
Damaged X-ray Equipment at Major Health Care Center
Published by Dranetz Technologies, Inc. Website: Dranetz.com Severe power quality problems damaged X-ray equipment, costing $100,000 in one instance. The source of the problem was the switch over from utility to generator power, during regular testing and emergency situations. Figure 1 (below) identified the cause of the problem, an out-of-phase transfer, captured by On Power with aContinue reading “Damaged X-ray Equipment at Major Health Care Center”
PQ Terms & Definitions
Published by Dranetz Technologies, Inc. Website: Dranetz.com PU (Per Unit) Explained PU stands for Per Unit. It is a term that electric utility engineers frequently use, and it was incorporated into IEEE 1159. PU is the percentage formed by dividing the actual voltage by the nominal. For example, a sag to 0.8 pu on a 480V circuitContinue reading “PQ Terms & Definitions”
Problems of Designing Electric Vehicle Charging Stations
Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and TechnologyORCID: 0000-0002-1628-1818; Abstract. The article presents the issues of designing electric vehicle charging stations. The general requirements that a vehicle charging station should meet are presented. The article focuses on the electric part of the vehicle charging station. Attention was also focused on the safety rulesContinue reading “Problems of Designing Electric Vehicle Charging Stations”
Renewable Energy Collector Transformers
Published by 1. Waldemar ZIOMEK, 2. Krishnamurthy VIJAYAN, PTI Transformers LP, Winnipeg, MB, Canada ORCID: 1. 0000-0002-1216-6513 Abstract. The renewable energy collector transformer (RCT) in a solar station, or a wind farm, transforms the voltage from the collector system to the transmission level voltages. As the primary goal is stepping up the voltage, the RCTContinue reading “Renewable Energy Collector Transformers”
Practical 400 Hz use Cases for Aviation Teams
Published by Dranetz Technologies, Inc. Below are three situations aviation teams often face, and how the HDPQ Xplorer 400 helps resolve them. Jetway keeps resetting when an aircraft connects What’s happening: During bridge movement or aircraft power-up, the 400 Hz supply dips. Sometimes it is a brief sag, other times a fast transient that trips protection.Continue reading “Practical 400 Hz use Cases for Aviation Teams”
UNIPOWER IEC 61000-4-30 Ed. 4
Published by Mr. Jonny Carlsson, Research Manager, Unipower AB, Sweden. Email: jonny.carlsson@unipower.se . Website: unipower.se Source URL: https://pqsynergy.com/assets/files/UNIPOWER-IEC61000-4-30Ed.4InprogressstateFDISMemberofWG9.pdf