Published by 1. Petr BOGATYREV, 2. Tomasz WOLNIK, ORCID: 1. 0000-0002-6589-8785; 2. 0000-0002-2636-8423 Abstract. The article presents an analysis of the influence design solutions of rotors with permanent magnets on the parameters and operating characteristics of a hydrogenerator designed for small hydropower plants (SHP). Internal Permanent Magnet (IPM) and Internal Permanent Magnet V-shaped rotor configurationsContinue reading “Analysis of Design Solutions for Rotors with Permanent Magnets for Small Hydropower Plants (SHP)”
Tag Archives: Total Harmonic Distortion (THD)
Testing the SDC memristors in Three Phase Systems
Published by 1. Bartłomiej GARDA, 2. Karol BEDNARZ, AGH University of KrakowORCID: 1. 0000-0001-6150-5617; 2. 0009-0007-6857-4851 Abstract. The objective outlined in the paper is to conduct reliable measurement tests on memristor behavior in three-phase systems. Memristors, acting as nonlinear elements, exhibit intriguing phenomena within such systems. Various configurations, including Delta and Wye connections with threeContinue reading “Testing the SDC memristors in Three Phase Systems”
Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network
Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and Technology. ORCID: 0000-0002-1628-1818 Abstract. Receivers such as power electronic devices, due to their widespread use and non-linear characteristics, are the most common cause of poor quality electricity. The share of non-linear receivers in the overall balance of power installed at a single customer increased to theContinue reading “Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network”
Interference Present in the Electrical Installation with Special Consideration of Higher Harmonics
Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and Technology. ORCID: 0000-0002-1628-1818 Abstract. Converter devices, i.e. computer power supplies prevalent in buildings, as well as LED light sources, which have replaced traditional light bulbs due to their widespread use and characteristics, are the most common cause of poor power quality. The construction of the devicesContinue reading “Interference Present in the Electrical Installation with Special Consideration of Higher Harmonics”
Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid
Published by 1. Aleksander CHUDY1, 2. Paweł MAZUREK1, 3. Korneliusz PAWLAK2, Lublin University of Technology (1), Ball Packaging Europe Lublin Sp. z o.o. (2) ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. In the present study, power quality parameters across two residential blocks, a single-family house, and an industrial facility were studied and evaluated. Compliance was generallyContinue reading “Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid”
An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant
Published by Jacek KOZYRA1, Zbigniew ŁUKASIK1, Aldona KUŚMIŃSKA-FIJAŁKOWSKA1, Piotr TAŃSKI2, Kazimierz Pulaski University of Radom, Faculty of Transport, Electrical Engineering and Computer Science (1) Baxtom Sp. z o.o, (2) ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031 Abstract. Poor quality of electric energy is a large problem for most of the enterprises and production plants takingContinue reading “An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant”
Damaged X-ray Equipment at Major Health Care Center
Published by Dranetz Technologies, Inc. Website: Dranetz.com Severe power quality problems damaged X-ray equipment, costing $100,000 in one instance. The source of the problem was the switch over from utility to generator power, during regular testing and emergency situations. Figure 1 (below) identified the cause of the problem, an out-of-phase transfer, captured by On Power with aContinue reading “Damaged X-ray Equipment at Major Health Care Center”
PQ Terms & Definitions
Published by Dranetz Technologies, Inc. Website: Dranetz.com PU (Per Unit) Explained PU stands for Per Unit. It is a term that electric utility engineers frequently use, and it was incorporated into IEEE 1159. PU is the percentage formed by dividing the actual voltage by the nominal. For example, a sag to 0.8 pu on a 480V circuitContinue reading “PQ Terms & Definitions”
Comparison of Compact Fluorescent to Incandescent Bulbs
Published by Dranetz Technologies, Inc., Case Study With the proliferation of Compact Florescent (CF) lighting, we thought it would be interesting to do a side by side comparison to an incandescent bulb using our new Energy Platform EP1. Not only is it a great demonstration of the capabilities of the EP1 but it’s also an opportunity toContinue reading “Comparison of Compact Fluorescent to Incandescent Bulbs”
A Novel Method to Improve the Power Quality Via Hybrid System
Published by 1. Raghad Adeeb Othman1, 2. Omar Sh. Alyozbaky2,Department of Electrical Engineering, College of Engineering, University of Mosul, Iraq (1,2)ORCID: 1. 0000-0001-5875-9210; 2. 0000-0002-9735-1469 Abstract. Ever increasing electricity demand as well as the rapid depletion of fossil fuels have increased the need for hybrid power systems that integrate distributed energy resource (DER) systems; suchContinue reading “A Novel Method to Improve the Power Quality Via Hybrid System”