Impact of EV Charging Stations Integration on Power System Performance

Published by Wisam Mohamed Najem1, Shaker M. Khudher2, Omar Sh. Alyozbaky3, Department of Electrical Engineering, College of Engineering, University of Mosul, Iraq (1,2,3) ORCID: 1.0000‐0002‐9611‐6416; 2.0000‐0003‐3158‐7900; 3.0000‐0002‐9735‐1469 Abstract. Electric vehicles partner with clean energy to prevent carbon emissions attributed to internal combustion engine-powered traditional vehicles, gas-based power plants, and other environmental pollution sources. At theContinue reading “Impact of EV Charging Stations Integration on Power System Performance”

Harmonic Measurement and Analysis during Electric Vehicle Charging

Published by Mohd Zamri Che Wanik1, Mohd FadzilMohd Siam1, Afida Ayob2, Subiyanto2, Azah Mohamed2, Abu HanifahAzit3, SaharuddinSulaiman3, Mohamed Azrin Mohamed Ali4, Zahrul Faizi Hussein1, Ahmad Kamil MatHussin1, 1TNB Research Malaysia, Malaysia, 2Power System Research Group, Universiti Kebangsaan Malaysia, Malaysia, 3TNB Distribution Malaysia, Malaysia, 4Malaysian Green Technology Corporation, Bandar BaruBangi, Malaysia. Email: mzamri@tnbr.com.my ABSTRACT This paperContinue reading “Harmonic Measurement and Analysis during Electric Vehicle Charging”

Steps to Find the Source of Harmonics

Published by David Horning, November 2014. Power Monitors, Inc., White Paper: Steps to Find the Source of Harmonics Abstract. Harmonics are “Non-Linear” current or voltage in an electrical system. Any waveform that deviates from a perfect sine wave has harmonics. Any nonlinear load draws harmonic currents and therefore produces harmonic voltage distortion, by producing non-sinusoidalContinue reading “Steps to Find the Source of Harmonics”

ADALINE Harmonics Extraction Algorithm applied to a Shunt Active Power Filter based on an Adaptive Fuzzy Hysteresis Current Control and a Fuzzy DC Voltage Controller

Published by Noureddine KHENFAR, Abdelhafid SEMMAH, Mohamed KADEM, Djillali Liabes University of Sidi Bel Abbes, Algeria. Abstract. This paper deals with the use of an adaptive linear (ADALINE) neural network in a harmonic extraction algorithm based on the calculation of instantaneous active and reactive powers. This technique, called “ANN-PQ”, is developed in order to achieveContinue reading “ADALINE Harmonics Extraction Algorithm applied to a Shunt Active Power Filter based on an Adaptive Fuzzy Hysteresis Current Control and a Fuzzy DC Voltage Controller”

Using the Method of the Spectral Analysis in Diagnostics of Electrical Process of Propulsion Systems Power Supply in Electric Car

Published by Yuriy BORODENKO1, Leonids RIBICKIS2, Anatolijs ZABASTA3, Shchasiana ARHUN4, Nadezhda KUNICINA5, Anastasia ZHIRAVETSKA6, Hanna HNATOVA7, Andrii HNATOV8, Antons PATLINS9, Konstantins KUNICINS10, Kharkiv National Automobile and Highway University (1), Riga Technical University (2), Riga Technical University (3), Kharkiv National Automobile and Highway University (4), Riga Technical University (5), Riga Technical University (6), Kharkiv National AutomobileContinue reading “Using the Method of the Spectral Analysis in Diagnostics of Electrical Process of Propulsion Systems Power Supply in Electric Car”

Power Quality Experimental Research at the Primorsky Wind Power Station

Published by Yuriy SAYENKO1, Ryszard PAWEŁEK2, Andrii MOLCHAN1, Ewa DYKA2, Pryazovskyi State Technical University (1)Lodz University of Technology, Institute of Electrical Power Engineering (2) Abstract. The article presents results of experimental studies of power quality indicators conducted at the wind farm with 52 DFIG wind turbines with a unit capacity of 3.8 MW by GeneralContinue reading “Power Quality Experimental Research at the Primorsky Wind Power Station”

Methods for Determining Power Losses in Cable Lines with Non-Linear Load

Published by Łukasz TOPOLSKI, Jurij WARECKI, Zbigniew HANZELKA, AGH University of Science and Technology Abstract. Harmonic currents in power cables cause additional power losses associated with phenomena that increase the temperature of the cable insulation and make its service life shorter. For these reasons, it is important to choose methods for determining active power losses,Continue reading “Methods for Determining Power Losses in Cable Lines with Non-Linear Load”

Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP

Published by Zia Hameed1, Muhammad Rafay Khan Sial2, Adnan Yousaf3, Muhammad Usman Hashmi,Faculty of Engineering and Technology, Superior University, 17-km off Raiwind Road Lahore PakistanEmails: zia.hameed@superior.edu.pk, rafay.khan@superior.edu.pk, adnan.yousaf@superior.edu.pk Abstract—Power System Harmonics is a real point of concern for Electrical Engineers. In power systems, non-linear loads are permanently connected, unlike transients and other distortions are produced.Continue reading “Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP”

An Update IEEEE Standard Complements

Published by Sivaraman P, SMIEEE, PEng (India), Senior Power Systems Engineer Chennai, Tamil Nadu, India We all know that Total Harmonic Distortion (THD) and Total Demand Distortion (TDD) are used to evaluate the presence of harmonics in the power system. The “IEEE Std 1547-2018 IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with AssociatedContinue reading “An Update IEEEE Standard Complements”

Computer Assisted Harmonics Analysis

Published by Prof. Silviu Darie, PhD (EE), Technical University Cluj Napoca, Romania, Honorary Member of the Romanian Technical Sciences Academy. Email: silviu.darie@enm.utcluj.ro. Abstract: Based on the author’s experience one describes in field tested methodologies which can be employed in solving the frequency-based power quality problems. A generic approach is presented and an experience-based assessment isContinue reading “Computer Assisted Harmonics Analysis”