Automated Power Factor Correction Through Microcontroller in Energy Sector

Published by 1. Pawan Kumar PANDEY1, 2. Ramesh KUMAR2, 3. Manish SINGLA2,3, 4. Sergey KOKIN4, 5. Murodbek SAFARALIEV4, 6. Javod AHYOEV3, Gyan Ganga Institute of Technology and Sciences (1), Chitkara University Institute of Engineering and Technology (2), Applied Science Private University (3), Ural Federal University (4), Tajik Technical University Named After Academician M.S. Osimi (5)ORCID:Continue reading “Automated Power Factor Correction Through Microcontroller in Energy Sector”

An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant

Published by Jacek KOZYRA1, Zbigniew ŁUKASIK1, Aldona KUŚMIŃSKA-FIJAŁKOWSKA1, Piotr TAŃSKI2, Kazimierz Pulaski University of Radom, Faculty of Transport, Electrical Engineering and Computer Science (1) Baxtom Sp. z o.o, (2) ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031 Abstract. Poor quality of electric energy is a large problem for most of the enterprises and production plants takingContinue reading “An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant”

Problems of Designing Electric Vehicle Charging Stations

Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and TechnologyORCID: 0000-0002-1628-1818; Abstract. The article presents the issues of designing electric vehicle charging stations. The general requirements that a vehicle charging station should meet are presented. The article focuses on the electric part of the vehicle charging station. Attention was also focused on the safety rulesContinue reading “Problems of Designing Electric Vehicle Charging Stations”

High impedance Fault Detection in Low Voltage Overhead Distribution based Wavelet and Harmonic Indices

Published by Enaam ALBANNA1, Alya H. AL-RIFAIE2, Ahmed A. Abdullah AL-KARAKCHI3, Northern Technical University (1,2,3) ORCID: 1. 0000-0002-3974-0116; 2. 0000-0002-7978-2193; 3. 0000-0003-1151-3015; Abstract. High-impedance fault HIF occurs when an energized conductor makes contact with a surface with a high impedance. Conventional overcurrent protection cannot detect this fault due to the low fault current, and thereContinue reading “High impedance Fault Detection in Low Voltage Overhead Distribution based Wavelet and Harmonic Indices”

Performance Comparison of Harmonic Filters in an Industrial Power System for Harmonic Distortion Reduction

Published by 1. Estifanos Dagnew Mitiku1, 2. Gebrie Teshome Aduye2, 3. S. Abdul Rahman3, 4. Mahilet Mentesinot Abuhay4, Electrical & Computer Engineering Department, Institute of Technology, University of Gondar, Ethiopia (1, 2, 3), Industrial Engineering Department, Institute of Technology, University of Gondar, Ethiopia (4) ORCID. 1. 0000-0002-6613-3979, 2. 0000-0003-1184-9184, 3. 0000-0003-0134-8028, 4. 0000-0001-7554-8562 Abstract: TheContinue reading “Performance Comparison of Harmonic Filters in an Industrial Power System for Harmonic Distortion Reduction”

Power Flow and Stability Analyses of a UPQC System Integrated into a Distribution Network

Published by Rachid Dehini1, Ryma Berbaoui, Othmane Abdelkhalek, Electrical engineering Department, University of Tahri Mohamed. B.P 417 BECHAR (08000), Algeria. ORCID: 1 https://orcid.org/0000-0002-8769-218X Abstract. This paper deals with the active and reactive power flow analysis inside the unified power quality conditioner (UPQC) during several cases. The UPQC is a combination of shunt and series activeContinue reading “Power Flow and Stability Analyses of a UPQC System Integrated into a Distribution Network”

Overview of Control System Topology of Flywheel Energy Storage System in Renewable Energy Application for Alternative Power Plant

Published by M.S. ALI1,2, Mahidur R SARKER3, Mohamad Hanif Md SAAD3, Ramizi MOHAMED1, 1Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia; 2Electrical Engineering Department, German-Malaysian Institute , Jalan Ilmiah, Taman Universiti,43000, Kajang, Selangor, Malaysia; 3Institute of IR 4.0, Universiti Kebangsaan Malaysia, 43600 UKM Bangi,Continue reading “Overview of Control System Topology of Flywheel Energy Storage System in Renewable Energy Application for Alternative Power Plant”

An Analysis of Power Quality Problems and its Mitigation

Published by Shafqat Mughal, Neeten Sharma, Pankhuri Kishore Abstract—Power Quality is a major concern of our modern industries and other consumers. Poor quality of supply will affect the performance of customer equipment such as computers, microprocessors adjustable speed drives, power electronic devices, life saving equipment in hospitals, etc. and result in heavy financial losses toContinue reading “An Analysis of Power Quality Problems and its Mitigation”

Case Study for Obtaining Power Quality Grid-Code Compliance

Published by Dirk A. J. van der Bank, and Kyle Lass, Energize, July 2018 The practical implications of obtaining power quality (PQ) grid-code compliance for category C photovoltaic (PV) renewable power plants (RPP) are described in this article. Successful harmonic mitigation was implemented via means of the installation of active harmonic filters (AHF) at lowContinue reading “Case Study for Obtaining Power Quality Grid-Code Compliance”

Investigation of the Line-Reactor Influence on the Active Power Filter and Hybrid Active Power Filter Efficiency: Practical Approach

Published by Chamberlin Stéphane Azebaze Mboving, Andrzej Firlit, AGH University of Science and Technology, Department of Power Electronics and Energy Control Systems Abstract. The shunt active power filter (SAPF) and hybrid active power filter (HAPF) efficiency does not only depends on their designed control system, but also on the parameters of the electrical system inContinue reading “Investigation of the Line-Reactor Influence on the Active Power Filter and Hybrid Active Power Filter Efficiency: Practical Approach”