Testing the SDC memristors in Three Phase Systems

Published by 1. Bartłomiej GARDA, 2. Karol BEDNARZ, AGH University of KrakowORCID: 1. 0000-0001-6150-5617; 2. 0009-0007-6857-4851 Abstract. The objective outlined in the paper is to conduct reliable measurement tests on memristor behavior in three-phase systems. Memristors, acting as nonlinear elements, exhibit intriguing phenomena within such systems. Various configurations, including Delta and Wye connections with threeContinue reading “Testing the SDC memristors in Three Phase Systems”

Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network

Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and Technology. ORCID: 0000-0002-1628-1818 Abstract. Receivers such as power electronic devices, due to their widespread use and non-linear characteristics, are the most common cause of poor quality electricity. The share of non-linear receivers in the overall balance of power installed at a single customer increased to theContinue reading “Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network”

The Measurement of Power Consumed by an Industrial Robot under Dynamic States

Published by Krzysztof OLESIAK, Czestochowa University of Technology ORCID: 0000-0003-4552-7810 Abstract. The paper presents a method of measuring power consumed by an industrial robot in a single phase system. A computer-based measurement set was constructed, consisting of special purpose voltage and current converters and a PC with a multi-channel measuring card. Measurements were conducted andContinue reading “The Measurement of Power Consumed by an Industrial Robot under Dynamic States”

Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation

Published by 1. Nuri Berisha, 2. Bahri Prebreza*, 3. Petrit Emini, Faculty of Electrical and Computer Engineering, University of PrishtinaORCID: 1. 0000-0001-8615-637X; 2. 0000-0003-1950-026X; 3. 0000-0002-2833-9001 Abstract. Power system harmonics have a significant impact on the efficiency, reliability, and stability of the system. Low power quality is determined by undervoltages and overvoltages, dips and swells,Continue reading “Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation”

Unipower – About Power Quality

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se Power quality is a generic term for disturbance-free electricity supply. Deviation from voltage sinusoidal waveform (50 Hz), which may result in equipment being disturbed or damaged, is to be regarded as a power quality disturbance. This means that the more sensitive equipment you connect toContinue reading “Unipower – About Power Quality”

A Case Study of Sharing the Harmonic Voltage Distortion Responsibility between the Utility and the Consumer

Published by F. H. Costa, I. N. Santos, S. F. P. Silva and J. C. de Oliveira, Group of Power Quality Faculty of Electrical Engineering Federal University of Uberlandia Campus Santa Monica – Av. João Naves de Ávila, 2100 Uberlandia (Brazil). Phone/Fax number:+55 (34) 3239-4733, e-mail: fernandahein@hotmail.com, ivan.ufu@gmail.com, sergio@qes.com.br, jcoliveira@ufu.br Abstract. The aim of thisContinue reading “A Case Study of Sharing the Harmonic Voltage Distortion Responsibility between the Utility and the Consumer”

Power System Harmonics

Published by Olutayo Ogunyemi, School of Science and Engineering, Atlantic International University, Honolulu, HI. Abstract – Good power quality is essential in electrical power network. Power quality is not limited to availability of supply but also include steady frequency value and voltage magnitude and smooth waveform characteristics of the supply (Ogheneovo Johnson, 2016).The present situationContinue reading “Power System Harmonics”

A Review of Harmonics Detection and Measurement in Power System

Published by 1. Dnyaneshwar D. Ahire, Professor, Matoshri College of Engineering and Research Centre, Nashik Savitribai Phule Pune University, Nashik, Maharashtra, India.2. Snehal R. Durdhavale Student, Matoshri College of Engineering and Research Centre, Nashik Savitribai Phule Pune University, Nashik, Maharashtra, India. ABSTRACT – A load is said to be “linear” when it draws a currentContinue reading “A Review of Harmonics Detection and Measurement in Power System”

A New Technique to Detect Harmonic Sources in Polluted Power Systems

Published by Pietro Vincenzo Barbaro, Antonio Cataliotti, Valentina Cosentino, Salvatore Nuccio, Dipartimento di Ingegneria Elettrica, Elettronica e delle Telecomunicazioni, Università di Palermo, Palermo, Italy. E-mails: barbaro@diepa.unipa.it, acataliotti@ieee.org, cosentino@diepa.unipa.it, nuccio@unipa.it Abstract: This paper presents a comparative analysis among different nonactive power quantities proposed in literature in nonsinusoidal conditions; with respect to this, a new single-point approachContinue reading “A New Technique to Detect Harmonic Sources in Polluted Power Systems”

Analysis of Interactions in the Circuit of the Power System with Nonlinear Load and LC Passive Filter

Published by Mirosław WCIŚLIK, Paweł STRZĄBAŁA,Kielce University of Technology, Department of Electric Engineering, Automatic Control and Computer Science Abstract. The paper deals with an AC circuit containing the nonlinear load and a LC passive filter. Nonlinear load voltage at the power terminals proportional to the signum function of current is considered. The current-voltage characteristic ofContinue reading “Analysis of Interactions in the Circuit of the Power System with Nonlinear Load and LC Passive Filter”