Computer Assisted Harmonics Analysis

Published by Prof. Silviu Darie, PhD (EE), Technical University Cluj Napoca, Romania, Honorary Member of the Romanian Technical Sciences Academy. Email: silviu.darie@enm.utcluj.ro. Abstract: Based on the author’s experience one describes in field tested methodologies which can be employed in solving the frequency-based power quality problems. A generic approach is presented and an experience-based assessment isContinue reading “Computer Assisted Harmonics Analysis”

Designing a Passive Filter for Reducing Harmonic Distortion in the Hybrid Micro-grid Including Wind Turbine, Solar Cell and Nonlinear Load

Published by Ali BAGHERI, Mohsen ALIZADEH, Department of Electrical Engineering, Yadegar -e- Imam Khomeini (RAH) Shahre Rey Branch, Islamic Azad University, Tehran, Iran Abstract. One of the most important indices of power quality in distribution grids is the harmonic distortion, which can affect the reliability of the micro-grid. On the other hand, the growth ofContinue reading “Designing a Passive Filter for Reducing Harmonic Distortion in the Hybrid Micro-grid Including Wind Turbine, Solar Cell and Nonlinear Load”

Solutions to Mitigate Harmonics

Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Solutions to mitigate harmonics There are three different types of solutions to attenuate harmonics: • Modifications in the installation• Special devices in the supply system• Filtering Basic solutions to mitigate harmonics To limit the propagation of harmonics in the distribution network, different solutions are availableContinue reading “Solutions to Mitigate Harmonics”

Main Effects of Harmonics in Electrical Installations

Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Main effects of harmonics in electrical installations Effects of harmonics – Resonance The simultaneous use of capacitive and inductive devices in distribution networks may result in parallel or series resonance. The origin of the resonance is the very high or very low impedance values atContinue reading “Main Effects of Harmonics in Electrical Installations”

Some Results of Research into Harmonics in the High Voltage Networks with Distributed Nonlinear Loads

Published by Lidiia KOVERNIKOVA, Energy Systems Institute of the Siberian Branch of the Russian Academy of Sciences Abstract. The paper presents the results of the analysis of harmonic parameters that were measured at the nodes of connecting railway substations to the feeding network. Traction load is nonlinear, unbalanced and stochastic. The 3-rd and 5-th harmonicsContinue reading “Some Results of Research into Harmonics in the High Voltage Networks with Distributed Nonlinear Loads”

Importance of Power Quality – Motor

Published by Emerich Energy Private Limited Power quality is of prime importance in deciding the efficiency of any motor. Some of the critical parameters of power quality are • Harmonics• Voltage Unbalance• Voltage Fluctuations In an alternating current (AC) system, the voltage potential and the current through the load circuit are described in frequency andContinue reading “Importance of Power Quality – Motor”

Harmonics Generation, Propagation and Purging Techniques in Non-Linear Loads

Published by Hadeed Ahmed Sher, Khaled E. Addoweesh and Yasin Khan 1. Introduction Industrial revolution has transformed the whole life with advanced technological improvements. The major contribution in the industrial revolution is due to the availability of electrical power that is distributed through electrical utilities around the world. The concept of power quality in thisContinue reading “Harmonics Generation, Propagation and Purging Techniques in Non-Linear Loads”

Harmonics / K-factor Ratings

Published by Siemens Canada, Siemens Limited Power Product Catalogue, Canadian Edition 2019. Section 18 – Technical, Contents: Harmonics / K-factor Ratings (18-16, 18-17) Non-Linear Loads When a sinusoidal voltage is applied to a linear load, the resultant current waveform takes on the shape of a sine wave as well. Typical linear loads are resistive heatingContinue reading “Harmonics / K-factor Ratings”

How reliable are transformer energy efficiency tests (including Independent 3rd Party) under non-linear loading?

Published by Mirus International Inc., [2010-01-08] MIRUS-FAQ001-B2, FAQ’s Harmonic Mitigating Transformers, 31 Sun Pac Blvd., Brampton, Ontario, Canada. L6S 5P6. It is much more difficult to accurately determine the energy efficiency of a transformer under non-linear loading than it is under linear loading. The industry accepted technique for measuring transformer efficiency under linear load involvesContinue reading “How reliable are transformer energy efficiency tests (including Independent 3rd Party) under non-linear loading?”

Real Time Sustainable Power Quality Analysis of Non-Linear Load under Symmetrical Conditions

Published by Pavan Babu Bandla 1, Indragandhi Vairavasundaram 1, Yuvaraja Teekaraman 2, Ramya Kuppusamy 3 and Srete Nikolovski 4,* 1School of Electrical Engineering, Vellore Institute of Technology, Vellore 632014, India2MOBI-Mobility, Logistics and Automotive Technology Research Centre, Vrije Universiteit Brussel, 1050 Brussels, Belgium3Department of Electrical and Electronics Engineering, Sri Sairam College of Engineering, Bangalore 562106, India4PowerContinue reading “Real Time Sustainable Power Quality Analysis of Non-Linear Load under Symmetrical Conditions”