Testing the SDC memristors in Three Phase Systems

Published by 1. Bartłomiej GARDA, 2. Karol BEDNARZ, AGH University of KrakowORCID: 1. 0000-0001-6150-5617; 2. 0009-0007-6857-4851 Abstract. The objective outlined in the paper is to conduct reliable measurement tests on memristor behavior in three-phase systems. Memristors, acting as nonlinear elements, exhibit intriguing phenomena within such systems. Various configurations, including Delta and Wye connections with threeContinue reading “Testing the SDC memristors in Three Phase Systems”

Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network

Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and Technology. ORCID: 0000-0002-1628-1818 Abstract. Receivers such as power electronic devices, due to their widespread use and non-linear characteristics, are the most common cause of poor quality electricity. The share of non-linear receivers in the overall balance of power installed at a single customer increased to theContinue reading “Disturbances Occurring in the Electrical Installation, with Particular Emphasis on the Negative Impact of Non-Linear Receivers on the Supply Network”

Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid

Published by 1. Aleksander CHUDY1, 2. Paweł MAZUREK1, 3. Korneliusz PAWLAK2, Lublin University of Technology (1), Ball Packaging Europe Lublin Sp. z o.o. (2) ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. In the present study, power quality parameters across two residential blocks, a single-family house, and an industrial facility were studied and evaluated. Compliance was generallyContinue reading “Analysis of Power Quality Parameters at Facilities Connected to the Municipal Electricity Grid”

Connecting European devices in the US

Published by Krzysztof BOLEK1, Mirosław CZECHOWSKI2, Tymoteusz NACZYŃSKI3, Politechnika Krakowska (1), Politechnika Krakowska (2), Politechnika Krakowska (3),ORCID: 1. 10009-0005-4756-8327.; 2. 0000-0001-5093-4870; 3. 0000-0003-0323-5393 Abstract. This article describes the concept of building an inexpensive power supply for testing devices in Poland whose destination is the USA. Firstly, the power grid configurations used in the USA isContinue reading “Connecting European devices in the US”

Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study

Published by Dranetz Technologies, Inc. Website: Dranetz.com  SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failures by installingContinue reading “Power Quality and Energy Monitoring in Controlled Environment Agriculture in New Jersey, USA, Case Study”

Switching Processes Occurring In Electrical Networks 10-35 kV

Published by 1. Ilham RAHIMLI1, 2. Aliashraf BAKHTIYAROV2, 3. Gulshan ABDULLAYEVA3, 4. Sona RZAYEVA4, Azerbaijan State Oil and Industry University (1, 2, 3, 4)ORCID: 1. 0009-0006-1976-4475; 3. 0000-0003-0168-9623; 4.0009.0006.6439.5699 Abstract. Due to the fact that high-voltage equipment solutions involve large capital investments, they are very important areas based on the scientific, technical and applied sectors.Continue reading “Switching Processes Occurring In Electrical Networks 10-35 kV”

A New Approach for Load shedding Scheme

Published by Houria SMAIL1, Yassine BENSAFIA2, PaElectrical Engineering Department, Faculty of Sciences and Applied sciences, University of Bouira, 10000 – Algeria (1), PaElectrical Engineering Department, Faculty of Sciences and Applied sciences, University of Bouira, 10000 – Algeria (2), ORCID: 1. 0000-0001-8474-2009; 2. 0000-0003-1760-3636 Abstract. Depending on the power system condition in terms of operating reserves,Continue reading “A New Approach for Load shedding Scheme”

Flexible Rogowski Current Probes in Measurements of Ultra-Fast SiC MOSFET Modules – Limitations and Challenges

Published by Dawid ZIĘBA1, Jacek RĄBKOWSKI2, Medcom Company (1), Warsaw University of Technology, Institute of Control and Industrial Electronics (2) ORCID: 1. 0000-0003-3789-6851; 2. 0000-0001-8857-3505 Abstract. The article presents a discussion on the limitations of the flexible Rogowski current probes in the measurements of switching processes in ultra-fast SiC MOSFET power modules. The probes featureContinue reading “Flexible Rogowski Current Probes in Measurements of Ultra-Fast SiC MOSFET Modules – Limitations and Challenges”

Prognosis of Insulation Deterioration in Induction Motors Winding Subject to Voltage Fluctuations

Published by 1. Ilham Bouaissi1, 2. Ali Rezig1, 3. Said Touati2, L2EI Laboratory, University Mohammed Seddik Benyahia, Ouled Aissa. Bp 98, Jijel, 18000, Algeria (1). Nuclear research center, Birine, Ain Oussera. Bp 180, Djelfa, 17200 Algeria (2) ORCID: 1. 0000-0001-5981-6918 Abstract. One of the problems with induction motors, say the experts, is voltage. Insulation deteriorationContinue reading “Prognosis of Insulation Deterioration in Induction Motors Winding Subject to Voltage Fluctuations”

Residual Current Devices in Electric Vehicles Charging Installations

Published by Stanislaw CZAPP, Gdańsk University of Technology, ORCID: 0000-0002-1341-8276 Abstract. The main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment forContinue reading “Residual Current Devices in Electric Vehicles Charging Installations”