Power Quality Lessons from an Controlled Environment Agriculture Facility

Published by Dranetz Technologies, Inc. Website: Dranetz.com  For controlled environment agriculture (CEA) operations, temperature, humidity, airflow, lighting, and CO₂ must stay within narrow limits 24/7 to foster growing conditions for high-value crops. When power quality deteriorates, environmental systems can go off-spec, putting these crops at risk. When HVAC and VFDs began failing unexpectedly, New Jersey CEAContinue reading “Power Quality Lessons from an Controlled Environment Agriculture Facility”

Multicore Underground Power Line Health Monitoring using Optical Fiber Bragg Grating

Published by M Hazwan WAHAB1,2, Mohammad Syuhaimi AB RAHMAN2, Ahmad Asrul IBRAHIM2, A H AHMAD ABAS1,2, Norhidayah AHMAD1,2, Quest International University (1), University Kebangsaan Malaysia (2) Abstract. Fiber Bragg grating (FBG) is a relatively novel method used for network health monitoring that has a number of advantages including high accuracy, multiplexing, electromagnetic interference resistance andContinue reading “Multicore Underground Power Line Health Monitoring using Optical Fiber Bragg Grating”

Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN

Published by Sri SUWASTI, Yiyin KLISTAFANI, Muhammad Ruswandi DJALAL, State Polytechnic of Ujung Pandang Abstract. The objective of this research is to develop a water cylinder filling pump integrated with a hybrid solar and grid (PLN) system. The performance of the pump is calculated to enable a comparative analysis with the energy and economic aspectsContinue reading “Application of Water Tube Filling Pump in Hybrid System of Solar Energy and PLN”

Switching Processes Occurring In Electrical Networks 10-35 kV

Published by 1. Ilham RAHIMLI1, 2. Aliashraf BAKHTIYAROV2, 3. Gulshan ABDULLAYEVA3, 4. Sona RZAYEVA4, Azerbaijan State Oil and Industry University (1, 2, 3, 4)ORCID: 1. 0009-0006-1976-4475; 3. 0000-0003-0168-9623; 4.0009.0006.6439.5699 Abstract. Due to the fact that high-voltage equipment solutions involve large capital investments, they are very important areas based on the scientific, technical and applied sectors.Continue reading “Switching Processes Occurring In Electrical Networks 10-35 kV”

Optimizing Electrical Energy Savings by Utilizing Refrigerant Catalysts in Compressors

Published by 1. Idris KUSUMA1, 2. R. RULIYANTA2, 3. Diah WIDIASTUTI, 4. Mohammad FATHONIUniversitas Nasional (1, 2, 3), Institut Teknologi Budi Utomo (4)ORCID: 1.0009-0006-1808-2229; 2.0000-0002-2439-330X; 4.0009.0006.6439.5699 Abstract. Even though the government of the Republic of Indonesia has banned the use of R22, it is still widely found in industry. The problem is that the industryContinue reading “Optimizing Electrical Energy Savings by Utilizing Refrigerant Catalysts in Compressors”

Current Harmonic Emission of On-Board Electric Vehicle Chargers

Published by Aleksander CHUDY, Department of Electrical Engineering and Electrotechnology, Faculty of Electrical Engineering and Computer Science Lublin University of Technology, ORCID: 0000-0002-3183-8450 Abstract. The case of study were 7 on-board EV chargers. The majority of current harmonics emission measurements during light-duty EVs charging took place in private garages of single-family houses in the LublinContinue reading “Current Harmonic Emission of On-Board Electric Vehicle Chargers”

Power Quality Inc. is Proud to Exhibit at the EPRI Power Quality Applications (PQA) Conference and Exhibition 2026!

Intelligent Power Quality for a Changing Grid: June 2-3, 2026, Charlotte, North Carolina, EPRI Charlotte Office & Conference Center, 1300 West W. T. Harris Blvd, Charlotte, NC, 28262, US Join us June 2–3 in Charlotte, NC to connect with power quality professionals focused on real‑world solutions. We provide power quality consulting, engineering services, training, and specialized tools to helpContinue reading “Power Quality Inc. is Proud to Exhibit at the EPRI Power Quality Applications (PQA) Conference and Exhibition 2026!”

What Makes a Power Quality Problem Worth Solving?

Published by Dranetz Technologies, Inc. Tech Tip: What Makes a Power Quality Problem Worth Solving?, Website: Dranetz.com  Most power quality events won’t shut you down. But when they do, they cost more than just a headache. The challenge isn’t detecting power quality problems. That’s the easy part. The real question is: Do those issues actually matter to your operation? AContinue reading “What Makes a Power Quality Problem Worth Solving?”

Power Quality Standards: What You Need to Know

Published by Dranetz Technologies, Inc. Tech Tip: Power Quality Standards: What You Need to Know, Website: Dranetz.com  If you’ve ever connected two different power quality meters to the same circuit and gotten different results, you’re not alone. It’s an age-old issue in power quality monitoring. And when it happens, the obvious question is: which reading should youContinue reading “Power Quality Standards: What You Need to Know”

Overview of Edge Computing Applications in Energy Sector

Published by Olga Pilipczuk, University of Szczecin ORCID: 0000-0001-7078-2544 Abstract. Currently, edge computing supports many solutions in the energy industry and has attracted the research interest of many researchers. The edge computing concept is relatively novel, the first impactful works were noticed in 2014-2015 years. Thus, there is a lack of studies summarizing the researchContinue reading “Overview of Edge Computing Applications in Energy Sector”