Published by Dranetz Technologies, Inc. Website: Dranetz.com Severe power quality problems damaged X-ray equipment, costing $100,000 in one instance. The source of the problem was the switch over from utility to generator power, during regular testing and emergency situations. Figure 1 (below) identified the cause of the problem, an out-of-phase transfer, captured by On Power with aContinue reading “Damaged X-ray Equipment at Major Health Care Center”
Tag Archives: Safety/Protection
Application Of Optical Current Sensors in Electric Substations
Published by Ilham RAHIMLI1, Aliashraf BAKHTIYAROV2, Gulshan ABDULLAYEVA3, Sona RZAYEVA4. Azerbaijan State Oil and Industry University ORCID: 1. 0009-0006-1976-4475; 3. 0000-0003-0168-9623; 4. 0000-0001-7086-9519 Abstract. Despite the fact that current transformers have been used for many years in certain sections of the electrical network, in power supply, to power the circuits of an electrical measuring installation,Continue reading “Application Of Optical Current Sensors in Electric Substations”
Modern Methods Of Evaluating the Technical Condition of Power Transformers
Published by Tural Aliyev1, Aydin Aliyev2,Azerbaijan State Oil and İndustry University, Baku, Azerbaijan ORCID: 1. 0000-0003-0751-3952, 2. 0000-0002-1631-0543 Abstract. This article aims to shed light on the critical aspects of power transformer assessment and proposes avenues for improvement in current methodologies, emphasizing the need for a more comprehensive and integrated approach to ensure the reliabilityContinue reading “Modern Methods Of Evaluating the Technical Condition of Power Transformers”
Research of Some Problems of Electrical Safety
Published by Elshad Safiyev1, Saida Kerimova2, Kubra Mukhtarova3, Azerbaijan State Oil and Industry University ORCID: 1. 0009-0005-4971-1721 Abstract. The article describes in detail the causes of electric danger, the types of its effects on the human body, and ways to protect against the danger. Schemes of connecting people to single-phase and two-phase current circuits andContinue reading “Research of Some Problems of Electrical Safety”
Prognosis of Insulation Deterioration in Induction Motors Winding Subject to Voltage Fluctuations
Published by 1. Ilham Bouaissi1, 2. Ali Rezig1, 3. Said Touati2, L2EI Laboratory, University Mohammed Seddik Benyahia, Ouled Aissa. Bp 98, Jijel, 18000, Algeria (1). Nuclear research center, Birine, Ain Oussera. Bp 180, Djelfa, 17200 Algeria (2) ORCID: 1. 0000-0001-5981-6918 Abstract. One of the problems with induction motors, say the experts, is voltage. Insulation deteriorationContinue reading “Prognosis of Insulation Deterioration in Induction Motors Winding Subject to Voltage Fluctuations”
Residual Current Devices in Electric Vehicles Charging Installations
Published by Stanislaw CZAPP, Gdańsk University of Technology, ORCID: 0000-0002-1341-8276 Abstract. The main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment forContinue reading “Residual Current Devices in Electric Vehicles Charging Installations”
Research of Methods Power Control of Wind Turbines
Published by Nijat Mammadov1, Ilkin Marufov2, Saadat Shikhaliyeva, Gulnara Aliyeva, Saida Kerimova,Azerbaijan State Oil and Industry UniversityORCID: 1. 0000-0001-6555-3632; 2. 0000-0002-3143-0113 Abstract. Currently, renewable energy sources play an important role in the global energy balance. Among them, wind electric installations occupy a special place. As wind turbines develop and their power increases, their design alsoContinue reading “Research of Methods Power Control of Wind Turbines”
Problems of Designing Electric Vehicle Charging Stations
Published by Marta BĄTKIEWICZ-PANTUŁA, Wrocław University of Science and TechnologyORCID: 0000-0002-1628-1818; Abstract. The article presents the issues of designing electric vehicle charging stations. The general requirements that a vehicle charging station should meet are presented. The article focuses on the electric part of the vehicle charging station. Attention was also focused on the safety rulesContinue reading “Problems of Designing Electric Vehicle Charging Stations”
Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems
Published by 1. Piotr GRYGIEL1,2, 2. Jan TARŁOWSKI2, 3. Krzysztof MIK3, Gdańsk University of Technology (1), Xdisc S.A.,Warsaw, Poland (2), Energy Conversion and Renewable Resources Research Centre, Polish Academy of Sciences, (3) ORCID: 1. 0000-0003-2769-9088; 3. 0000-0002-9510-3066 Abstract. Two types of full-size photovoltaic modules for on-grid systems with maximum DC voltage of 600 V haveContinue reading “Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems”
Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey
Published by 1. Lenin Babu Chilakapati, 2. T Gowri Manohar, SVU College of Engineering, Sri Venkateswara University. ORCID: 1.0000-0001-9749-979X; 2.0000-0003-0441-6022 Abstract. Renewable energy technologies are becoming more and more common for generating electricity because they are environmentally friendly and can meet local electricity needs. They reduce network congestion and also lighten the load on conventionalContinue reading “Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey”