What Makes a Power Quality Problem Worth Solving?

Published by Dranetz Technologies, Inc. Tech Tip: What Makes a Power Quality Problem Worth Solving?, Website: Dranetz.com  Most power quality events won’t shut you down. But when they do, they cost more than just a headache. The challenge isn’t detecting power quality problems. That’s the easy part. The real question is: Do those issues actually matter to your operation? AContinue reading “What Makes a Power Quality Problem Worth Solving?”

Increasing the Impulse Electrical Strength of Winding Insulationof High-Voltage Transformers

Published by Elbrus AHMEDOV1, Nadir ALİYEV2, Seymur SADIQOV3,Azerbaijan State Oil and Industry University (1, 2) ORCID: 1. 0000-0003-3348-7946; 2. 0009-0001-3165-1493 Abstract. The present article delves into strategies aimed at augmenting the impulse electrical strength of the insulation in high-voltage transformer windings. The research focal point centers on an authentically produced autotransformer boasting a 330 kVContinue reading “Increasing the Impulse Electrical Strength of Winding Insulationof High-Voltage Transformers”

Design of a Protection System for Distributed Energy Sources in Distribution Grids

Published by 1. Róbert Štefko1, 2. Michal Kolcun1, 3. Marek Bobček1, 4. Damian Mazur2 , 5. Bogdan Kwiatkowski2, Technical University of Košice (1), Rzeszow University of Technology (2) ORCID: 1. 0000-0002-2477-4559, 2. 0000-0002-8041-9076, 3. 0009-0004-1912-211X; 4. 0000-0002-3247-5903, 5. 0000-0001-5287-2191 Abstract. The continuous rise in electricity consumption and the integration of renewable energy sources into distributionContinue reading “Design of a Protection System for Distributed Energy Sources in Distribution Grids”

Data Center Commissioning Case Study

Published by Dranetz Technologies, Inc. Website: Dranetz.com  Most high reliability facilities have a significant investment in UPS systems, generators and other mitigation devices in order to prevent electrical supply problems from impacting their business. However, these mitigation devices and related equipment are complex electro-mechanical systems that are themselves susceptible to failure and often do not provide anyContinue reading “Data Center Commissioning Case Study”

Overvoltage on the High and Low Side Electrical Network Voltage 35 kV When Appearing and Disconnecting Short Circuits of Various Forms at Its High Voltage Part

Published by Nahid MUFIDZADA1, Gulgaz ISMAYILOVA2, Azerbaijan State Oil and Industry University ORCID: 1. 0000-0003-4063-2128, 2. 0000-0003-0063-2020 Abstract. Overvoltage is explored on the 35, 10 and 6 kV sides of the electrical network where various characters short circuit occur on its highvoltage part. It has been revealed that the overvoltage which occurs during a shortContinue reading “Overvoltage on the High and Low Side Electrical Network Voltage 35 kV When Appearing and Disconnecting Short Circuits of Various Forms at Its High Voltage Part”

A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks

Published by Jalal Ibrahimov1, Tural Aliyev2, Ilkin Marufov3, Nijat Mammadov4, Azerbaijan State Oil and Industry University ORCID: 3. 0000-0002-3143-0113; 4. 0000-0001-6555-3632 Abstract. The widespread use of electric automobiles will lead to significant changes in instantaneous consumption values and the mechanisms that govern this consumption. Electricity demand will increase sharply and there will be fluctuations inContinue reading “A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks”

Assessment of the Danger of using Ultraviolet Lamps in Electrical Systems

Published by 1. Anatolii SEMENOV1, 2. Stanislav POPOV1, 3. Serhii YAKHIN1, 4. Bauyrzhan YELEUSSINOV2, 5.Tamara SAKHNO1, Poltava State Agrarian University (1), Branch of JSC «NCPD Orleu» Institute of professional development in Kyzylorga region (2) ORCID: 1. 0000-0003-3184-6925; 2. 0000-0003-2381-152X; 3. 0000-0002-0042-0844; 4. 0009-0005-0552-6794; 5. 0000-0001-7049-4657 Abstract. To determine the photobiological safety of UV lamps, theContinue reading “Assessment of the Danger of using Ultraviolet Lamps in Electrical Systems”

International Standards for Power Quality Measurement Systems

Published by P Axelberg, Unipower AB, Sweden & M H. J. Bollen, Chalmers University of Technology, Sweden I. INTRODUCTION During the last decade, there has been an increasing focus on power quality (PQ). The interest and demand for quality assurance of electrical power has several fundamental causes. First of all, electrical power can be consideredContinue reading “International Standards for Power Quality Measurement Systems”

Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network

Published by Wiktoria GRYCAN, Wroclaw University of Science and Technology, ORCID: 0000-0001-8121-7612 Abstract. Prosumerism is inherently designed to be a tool that alleviates the grid. Still, not every prosumer aligns the consumption profile with the energy generation profile in photovoltaic installations. Therefore, the rapid development of Renewable Energy Sources (RES) in Poland, especially photovoltaic installations,Continue reading “Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network”

Some Issues of Increasing the Efficiency of Electric Machines

Published by Samira KHANAHMEDOVA, Azerbaijan State Oil and Industry UniversityORCID: 0000-0001-8862-1570 Abstract. The article discusses ways to reduce losses to increase efficiency in electric machines. The amount of energy loss is determined by the efficiency coefficient. The issues of changing the size of an electric machine under electromagnetic loads with a constant power source andContinue reading “Some Issues of Increasing the Efficiency of Electric Machines”