Analysis of Electrical Generators for Wind Electric Installations

Published by Aliashraf BAKHTIYAROV1, Gulshan ABDULLAYEVA2, Hamid PIRIYEV3, Azerbaijan State Oil and Industry University ORCID: 2. 0000-0003-0168-9623; 3. 0009-0000-2992-6358 Abstract. In today’s world, when the role of renewable energy sources is becoming increasingly important in the context of combating climate change and reducing dependence on fossil fuels, wind energy occupies a leading position. Wind turbinesContinue reading “Analysis of Electrical Generators for Wind Electric Installations”

A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks

Published by Jalal Ibrahimov1, Tural Aliyev2, Ilkin Marufov3, Nijat Mammadov4, Azerbaijan State Oil and Industry University ORCID: 3. 0000-0002-3143-0113; 4. 0000-0001-6555-3632 Abstract. The widespread use of electric automobiles will lead to significant changes in instantaneous consumption values and the mechanisms that govern this consumption. Electricity demand will increase sharply and there will be fluctuations inContinue reading “A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks”

International Standards for Power Quality Measurement Systems

Published by P Axelberg, Unipower AB, Sweden & M H. J. Bollen, Chalmers University of Technology, Sweden I. INTRODUCTION During the last decade, there has been an increasing focus on power quality (PQ). The interest and demand for quality assurance of electrical power has several fundamental causes. First of all, electrical power can be consideredContinue reading “International Standards for Power Quality Measurement Systems”

Improving Energy Output and Efficiency of PV Installations using Bifacial Panels in Public Facilities

Published by 1. Jacek KUSZNIER, 2. Marcin SULKOWSKI, 3. Gabriela Druć, Bialystok University of Technology, Faculty of Electrical Engineering ORCID: 1. 0000-0001-8436-5717; 2. 0000-0002-3079-314X Abstract. The issue of improving the energy efficiency of photovoltaic installations is very important due to the limited location options in public facilities. Therefore, this paper presents the possibilities of improvingContinue reading “Improving Energy Output and Efficiency of PV Installations using Bifacial Panels in Public Facilities”

Revenue Accurate vs. Revenue Certified/Grade

Published by Dranetz Technologies, Inc., Technical Documents – White Paper INTRODUCTION In addition to our energy metering products, most Dranetz Power Quality products can also compute and measure common energy parameters such as W, VA, VAR, PF, Demand, Energy, and more. The ability to measure energy in addition to PQ opens the door to many more applications,Continue reading “Revenue Accurate vs. Revenue Certified/Grade”

An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant

Published by Jacek KOZYRA1, Zbigniew ŁUKASIK1, Aldona KUŚMIŃSKA-FIJAŁKOWSKA1, Piotr TAŃSKI2, Kazimierz Pulaski University of Radom, Faculty of Transport, Electrical Engineering and Computer Science (1) Baxtom Sp. z o.o, (2) ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031 Abstract. Poor quality of electric energy is a large problem for most of the enterprises and production plants takingContinue reading “An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant”

Some Issues of Increasing the Efficiency of Electric Machines

Published by Samira KHANAHMEDOVA, Azerbaijan State Oil and Industry UniversityORCID: 0000-0001-8862-1570 Abstract. The article discusses ways to reduce losses to increase efficiency in electric machines. The amount of energy loss is determined by the efficiency coefficient. The issues of changing the size of an electric machine under electromagnetic loads with a constant power source andContinue reading “Some Issues of Increasing the Efficiency of Electric Machines”

Damaged X-ray Equipment at Major Health Care Center

Published by Dranetz Technologies, Inc. Website: Dranetz.com  Severe power quality problems damaged X-ray equipment, costing $100,000 in one instance. The source of the problem was the switch over from utility to generator power, during regular testing and emergency situations. Figure 1 (below) identified the cause of the problem, an out-of-phase transfer, captured by On Power with aContinue reading “Damaged X-ray Equipment at Major Health Care Center”

PQ Terms & Definitions

Published by Dranetz Technologies, Inc. Website: Dranetz.com  PU (Per Unit) Explained PU stands for Per Unit. It is a term that electric utility engineers frequently use, and it was incorporated into IEEE 1159. PU is the percentage formed by dividing the actual voltage by the nominal. For example, a sag to 0.8 pu on a 480V circuitContinue reading “PQ Terms & Definitions”

Modern Methods Of Evaluating the Technical Condition of Power Transformers

Published by Tural Aliyev1, Aydin Aliyev2,Azerbaijan State Oil and İndustry University, Baku, Azerbaijan ORCID: 1. 0000-0003-0751-3952, 2. 0000-0002-1631-0543 Abstract. This article aims to shed light on the critical aspects of power transformer assessment and proposes avenues for improvement in current methodologies, emphasizing the need for a more comprehensive and integrated approach to ensure the reliabilityContinue reading “Modern Methods Of Evaluating the Technical Condition of Power Transformers”