Published by Jacek KOZYRA1, Zbigniew ŁUKASIK1, Aldona KUŚMIŃSKA-FIJAŁKOWSKA1, Piotr TAŃSKI2, Kazimierz Pulaski University of Radom, Faculty of Transport, Electrical Engineering and Computer Science (1) Baxtom Sp. z o.o, (2) ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031 Abstract. Poor quality of electric energy is a large problem for most of the enterprises and production plants takingContinue reading “An Analysis of Elimination of Interferences in the Supply System of An Industrial Plant”
Category Archives: Case Studies
Flexible Rogowski Current Probes in Measurements of Ultra-Fast SiC MOSFET Modules – Limitations and Challenges
Published by Dawid ZIĘBA1, Jacek RĄBKOWSKI2, Medcom Company (1), Warsaw University of Technology, Institute of Control and Industrial Electronics (2) ORCID: 1. 0000-0003-3789-6851; 2. 0000-0001-8857-3505 Abstract. The article presents a discussion on the limitations of the flexible Rogowski current probes in the measurements of switching processes in ultra-fast SiC MOSFET power modules. The probes featureContinue reading “Flexible Rogowski Current Probes in Measurements of Ultra-Fast SiC MOSFET Modules – Limitations and Challenges”
Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network
Published by Wiktoria GRYCAN, Wroclaw University of Science and Technology, ORCID: 0000-0001-8121-7612 Abstract. Prosumerism is inherently designed to be a tool that alleviates the grid. Still, not every prosumer aligns the consumption profile with the energy generation profile in photovoltaic installations. Therefore, the rapid development of Renewable Energy Sources (RES) in Poland, especially photovoltaic installations,Continue reading “Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network”
Some Issues of Increasing the Efficiency of Electric Machines
Published by Samira KHANAHMEDOVA, Azerbaijan State Oil and Industry UniversityORCID: 0000-0001-8862-1570 Abstract. The article discusses ways to reduce losses to increase efficiency in electric machines. The amount of energy loss is determined by the efficiency coefficient. The issues of changing the size of an electric machine under electromagnetic loads with a constant power source andContinue reading “Some Issues of Increasing the Efficiency of Electric Machines”
Damaged X-ray Equipment at Major Health Care Center
Published by Dranetz Technologies, Inc. Website: Dranetz.com Severe power quality problems damaged X-ray equipment, costing $100,000 in one instance. The source of the problem was the switch over from utility to generator power, during regular testing and emergency situations. Figure 1 (below) identified the cause of the problem, an out-of-phase transfer, captured by On Power with aContinue reading “Damaged X-ray Equipment at Major Health Care Center”
Application Of Optical Current Sensors in Electric Substations
Published by Ilham RAHIMLI1, Aliashraf BAKHTIYAROV2, Gulshan ABDULLAYEVA3, Sona RZAYEVA4. Azerbaijan State Oil and Industry University ORCID: 1. 0009-0006-1976-4475; 3. 0000-0003-0168-9623; 4. 0000-0001-7086-9519 Abstract. Despite the fact that current transformers have been used for many years in certain sections of the electrical network, in power supply, to power the circuits of an electrical measuring installation,Continue reading “Application Of Optical Current Sensors in Electric Substations”
Testing of a Micro Hydro Power Plant Using a Cross-Flow Type Turbine
Published by Sri SUWASTI, Musrady MULYADI, Yiyin KLISTAFANI, Muhammad Ruswandi DJALAL, State Polytechnic of Ujung Pandang Abstract: The implementation of Micro Hydro Power Plants (MHPP) serves as a crucial initiative to address the uneven distribution of electrical energy in remote areas across Indonesia. Before the permanent installation of an MHPP, field testing is imperative, involvingContinue reading “Testing of a Micro Hydro Power Plant Using a Cross-Flow Type Turbine”
Modern Methods Of Evaluating the Technical Condition of Power Transformers
Published by Tural Aliyev1, Aydin Aliyev2,Azerbaijan State Oil and İndustry University, Baku, Azerbaijan ORCID: 1. 0000-0003-0751-3952, 2. 0000-0002-1631-0543 Abstract. This article aims to shed light on the critical aspects of power transformer assessment and proposes avenues for improvement in current methodologies, emphasizing the need for a more comprehensive and integrated approach to ensure the reliabilityContinue reading “Modern Methods Of Evaluating the Technical Condition of Power Transformers”
Considerations for Energy Saving and Street Lighting Lamps Replacement in Jordanian Roads
Published by Adnan M Al-Smadi, Tariq M Alrjoub, Yarmouk University, Hijjawi Faculty for Engineering Technology, Jordan ORCID:000-0003-3796-6805X Abstract. For the last several years, the demand for electricity in Jordan has increased. This increase is due to the change of climate conditions and high temperatures, which led to the increase of the use of air conditioningContinue reading “Considerations for Energy Saving and Street Lighting Lamps Replacement in Jordanian Roads”
Efficient High Voltage Gain Simplified DC-DC Converter for Enhanced Solar Power Harvesting
Published by Shanmugavadivu Natarajan, Department of Electrical and Electronics Engineering, Sri Venkateswara College of Engineering, Sriperumbudur, 602117, India Abstract. This study introduces a novel transformerless high voltage gain DC-DC converter for solar power. It combines a two-inductor boost converter, voltage multiplier, and switched capacitor cells, achieving a remarkable high voltage gain with 98.24% efficiency. AContinue reading “Efficient High Voltage Gain Simplified DC-DC Converter for Enhanced Solar Power Harvesting”