Published by Dranetz Technologies, Inc. Below are three situations aviation teams often face, and how the HDPQ Xplorer 400 helps resolve them. Jetway keeps resetting when an aircraft connects What’s happening: During bridge movement or aircraft power-up, the 400 Hz supply dips. Sometimes it is a brief sag, other times a fast transient that trips protection.Continue reading “Practical 400 Hz use Cases for Aviation Teams”
Tag Archives: Power System
The Importance of Diagnostics of Electrical Equipment at Thermal Power Plants for Ensuring the Reliability of Power Systems
Published by Elshad Safiyev1, Sona RZAYEVA2, Rashida KARIMOVA3, Azerbaijan State Oil and Industry University (1, 2, 3) ORCID: 1. 0009-0005-4971-1721; 2.0000-0001-7086-9519 Abstract. This article discusses the importance of diagnostics of electrical equipment in thermal power plants to ensure the reliability of power systems. Electrical equipment is a key component in the production and transmission ofContinue reading “The Importance of Diagnostics of Electrical Equipment at Thermal Power Plants for Ensuring the Reliability of Power Systems”
Power Quality Measurements from the Spain – Portugal Blackout
Published by Mr. Thomas Ottosson, Managing Director, Unipower AB, Sweden. Email: thomas.ottosson@unipower.se . Website: unipower.se Source URL: https://pqsynergy.com/assets/files/Power-QualityMeasurementsfromtheSpainPortugalBlackout.pdf
UNIPOWER IEC 61000-4-30 Ed. 4
Published by Mr. Jonny Carlsson, Research Manager, Unipower AB, Sweden. Email: jonny.carlsson@unipower.se . Website: unipower.se Source URL: https://pqsynergy.com/assets/files/UNIPOWER-IEC61000-4-30Ed.4InprogressstateFDISMemberofWG9.pdf
Protection of DC Microgrid using ΔCB
Published by 1. Marwan R. Abed, 2. Oday A. Ahmed, 3. Ghassan A. Bilal, University of Technology Iraq, Baghdad, ORCID: 1. 0000-0002-1257-2810; 2. 0000-0001-7214-3412; 3. 0000-0002-5090-103X Abstract. When implementing a DC distribution network, it is much easier to integrate distributed energy sources than it is with an ac grid. Furthermore, the efficiency and reliability ofContinue reading “Protection of DC Microgrid using ΔCB”
Manage Your Energy Expenses
Published by Dranetz Technologies, Inc., Case Study Utility energy and demand costs have a direct impact on a company’s bottom line. In fact, a typical commercial or industrial facility can save from 10% to as much as 35% annually on energy costs by implementing a comprehensive energy management plan. And while each facility will require an organizedContinue reading “Manage Your Energy Expenses”
Investigating Blinky Lights
Published by Dranetz Technologies, Inc., Technical Documents he HDPQ Family of products have a number of trigger mechanisms for capturing different types of power quality phenomena. Most users are familiar with settings for sags and swells, but those typical limits usually don’t capture the “blinky lights” problems. While the Pst (perceptibility short term) parameter will indicate whether the voltageContinue reading “Investigating Blinky Lights”
Modelling of Passive Cooling Systems for Solar Panels
Publised by Oleh HOLOVKO1, Adam KONIECZKA2, Adam DĄBROWSKI3, Politechnika Poznańska, Wydział Automatyki, Robotyki i Elektrotechniki (1, 2, 3)ORCID: 2. 0000-0002-0362-3006; 3. 0000-0002-9385-6080O Abstract. This paper proposes a method for evaluating the efficiency of passive cooling systems of solar panels in a type of radiator using CFD simulations. The movement of air through the cooling systemContinue reading “Modelling of Passive Cooling Systems for Solar Panels”
Power System Flexibility Assessment for Future Flexibility Needs: High-Level Screening Method of the Macedonian Power System
Published by 1. Stojan MALCHESKI1, 2. Sime KUZAREVSKI1, 3. Jovica VULETIC2, 4. Jordanco ANGELOV2, 5. Mirko TODOROVSKI2, Macedonian Transmission System Operator (MEPSO) (1), University of Ss. Cyril and Methodius, Faculty of Electrical Engineering and Information Technologies, Power Systems Department (2) ORCID: 1. /; 2. /; 3. 0000-0002-1009-7315; 4. 0000-0002-8749-6306; Abstract. With the European aim toContinue reading “Power System Flexibility Assessment for Future Flexibility Needs: High-Level Screening Method of the Macedonian Power System”
Data Centers Utilize Distributed Generation to Improve Reliability and Profitability
Published by Dranetz Technologies, Inc., Case Study Distributed Generation (DG) is a method of Demand Response (DR) which is available in select areas of the world. DG has significant implications to both the data center operations and overall profitability. DG is the basic act of relieving the utility grid of desperately needed electrical loads during system economicContinue reading “Data Centers Utilize Distributed Generation to Improve Reliability and Profitability”