Published by A. Testa member IEEE, D. Gallo student member IEEE, R. Langella member IEEE Abstract: The harmonic and interharmonic analysis recommendations contained in the latest IEC standards on Power Quality are considered. The spectral leakage problems, due to synchronization errors of the analysed waveforms with the window widths adopted are analysed. Improvements of theContinue reading “On the Processing of Harmonics and Interharmonics: Using Hanning Window in Standard Framework”
Tag Archives: Power System
Higher Harmonics Filtration in the Power Supply System of Thyristor Hoisting Machine of Shaft Transport in a Mining Plant
Published by Marian HYLA, Silesian University of Technology, Department of Power Electronics, Electrical Drives and Robotics. ORCID: 0000-0001-6466-7398 Abstract. The paper presents the issues of the influence on the supply electrical power grid of the thyristor rectifier supplying high power receivers such as a shaft hoisting machines in mining. The current distortion influence of theContinue reading “Higher Harmonics Filtration in the Power Supply System of Thyristor Hoisting Machine of Shaft Transport in a Mining Plant”
The Mathematical Model of High Voltage Switch as An Element of a Power System
Published by 1. Andriy CZABAN1, 2. Vitaliy LEVONIUK2, 3. Radosław FIGURA1,Kazimierz Pulaski University of Technology and Humanities in Radom (1), Lviv National Agrarian University (2) ORCID: 1. – 0000-0002-4620-301X; 2. 0000-0003-2113-107X; ; 3. 0000-0001-8048-5623 Abstract. In this work, on the basis of an interdisciplinary method of modelling, a mathematical model of a power system isContinue reading “The Mathematical Model of High Voltage Switch as An Element of a Power System”
Storage Electric Multiple Units on Partially Electrified Suburban Railway Lines
Published by Aleksander JAKUBOWSKI1, Natalia KARKOSIŃSKA–BRZOZOWSKA2, Krzysztof KARWOWSKI1, Andrzej WILK1, Gdańsk University of Technology, Faculty of Electrical and Control Engineering (1), Civil and Environmental Engineering (2) Abstract. The paper presents possible environmental, energy and economical gains implied by replacing conventional traction vehicles with independently powered electric multiple units (IPEMU) on partially electrified suburban railways. IPEMUsContinue reading “Storage Electric Multiple Units on Partially Electrified Suburban Railway Lines”
Memristive Devices In Three-Phase Systems
Published by Piotr ZEGARMISTRZ, Bartłomiej GARDA, AGH University of Science and Technology Abstract. The aim of the research presented in a paper was to provide trustworthy simulation results for symmetrical three-phase systems with memristive load. The memristors in the system are combined with linear resistors in order to limit the current in the element. LinearContinue reading “Memristive Devices In Three-Phase Systems”
Comparative Analysis of the Indicators that Concern Power Supply Interruptions for Electricity Consumers for the Selected Distribution System
Published by Małgorzata ŁATKA, Marek NOWAK, Rzeszow University of Technology Abstract. The article presents the results of a comparative analysis of the basic indicators characterizing the interruptions in the supply of electricity. On the basis of generally available reports of selected DSOs, a list of selected indicators was prepared over the years. A comparison ofContinue reading “Comparative Analysis of the Indicators that Concern Power Supply Interruptions for Electricity Consumers for the Selected Distribution System”
Incheon Airport Maglev Line
Published by Doh-Young PARK1, Jacek F. GIERAS2,3Korea Institute of Machinery and Materials, Daejeon, Korea (1), UTP University of Science and Technology, Bydgoszcz, Poland (2), Korea Electrotechnology Research Institute, Changwon, Korea (3), Abstract. The paper presents the Incheon Airport Maglev Line (IAML) in South Korea connecting Incheon Airport with Yeongjong Island. The paper focuses on constructionContinue reading “Incheon Airport Maglev Line”
Obtaining Feasibility of Power Flows in the Deregulated Electricity Market Environment
Published by Mariusz DRABECKI, Eugeniusz TOCZYŁOWSKI,Warsaw University of Technology, Institute of Control and Computation Engineering Abstract. In this paper we analyse a power dispatch method for obtaining feasible power flows, both active and reactive power, in terms of satisfying the transmission, voltage level and voltage angles’ constraints, under assumption that supply of electric power isContinue reading “Obtaining Feasibility of Power Flows in the Deregulated Electricity Market Environment”
Steps to Find the Source of Harmonics
Published by David Horning, November 2014. Power Monitors, Inc., White Paper: Steps to Find the Source of Harmonics Abstract. Harmonics are “Non-Linear” current or voltage in an electrical system. Any waveform that deviates from a perfect sine wave has harmonics. Any nonlinear load draws harmonic currents and therefore produces harmonic voltage distortion, by producing non-sinusoidalContinue reading “Steps to Find the Source of Harmonics”
Investigation of Power Saving Modes in 10/0.4 kV Distribution Networks
Published by Oleksandr MIROSHNYK1, Andrzej SZAFRANIEC2, Kharkiv Petro Vasylenko National Technical University of Agriculture (1), Kazimierz Pulaski University of Technology and Humanities in Radom, Faculty of Transport, Electrical Engineering and Computer Science (2) Abstract. Operation modes of 0.4/0.23 kV power supply systems are modelled using Monte Carlo method by means of Electronics Workbench software and statisticalContinue reading “Investigation of Power Saving Modes in 10/0.4 kV Distribution Networks”