Published by Olga Pilipczuk, University of Szczecin ORCID: 0000-0001-7078-2544 Abstract. Currently, edge computing supports many solutions in the energy industry and has attracted the research interest of many researchers. The edge computing concept is relatively novel, the first impactful works were noticed in 2014-2015 years. Thus, there is a lack of studies summarizing the researchContinue reading “Overview of Edge Computing Applications in Energy Sector”
Tag Archives: energy
Design of a Protection System for Distributed Energy Sources in Distribution Grids
Published by 1. Róbert Štefko1, 2. Michal Kolcun1, 3. Marek Bobček1, 4. Damian Mazur2 , 5. Bogdan Kwiatkowski2, Technical University of Košice (1), Rzeszow University of Technology (2) ORCID: 1. 0000-0002-2477-4559, 2. 0000-0002-8041-9076, 3. 0009-0004-1912-211X; 4. 0000-0002-3247-5903, 5. 0000-0001-5287-2191 Abstract. The continuous rise in electricity consumption and the integration of renewable energy sources into distributionContinue reading “Design of a Protection System for Distributed Energy Sources in Distribution Grids”
Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study
Published by Dranetz Technologies, Inc., Technical Documents – Application Note SUMMARY Controlled environment agriculture (CEA) relies on advanced technologies such as climate control systems, artificial lighting, and hydroponic or aeroponic growing systems. These systems, in turn, require stable, clean power. This Application Note outlines how a New Jersey-based indoor farming facility addressed persistent HVAC and VFD failuresContinue reading “Power Quality & Energy Monitoring in Controlled Environment Agriculture: A New Jersey, USA Case Study”
A New Approach for Load shedding Scheme
Published by Houria SMAIL1, Yassine BENSAFIA2, PaElectrical Engineering Department, Faculty of Sciences and Applied sciences, University of Bouira, 10000 – Algeria (1), PaElectrical Engineering Department, Faculty of Sciences and Applied sciences, University of Bouira, 10000 – Algeria (2), ORCID: 1. 0000-0001-8474-2009; 2. 0000-0003-1760-3636 Abstract. Depending on the power system condition in terms of operating reserves,Continue reading “A New Approach for Load shedding Scheme”
Analysis of Electrical Generators for Wind Electric Installations
Published by Aliashraf BAKHTIYAROV1, Gulshan ABDULLAYEVA2, Hamid PIRIYEV3, Azerbaijan State Oil and Industry University ORCID: 2. 0000-0003-0168-9623; 3. 0009-0000-2992-6358 Abstract. In today’s world, when the role of renewable energy sources is becoming increasingly important in the context of combating climate change and reducing dependence on fossil fuels, wind energy occupies a leading position. Wind turbinesContinue reading “Analysis of Electrical Generators for Wind Electric Installations”
A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks
Published by Jalal Ibrahimov1, Tural Aliyev2, Ilkin Marufov3, Nijat Mammadov4, Azerbaijan State Oil and Industry University ORCID: 3. 0000-0002-3143-0113; 4. 0000-0001-6555-3632 Abstract. The widespread use of electric automobiles will lead to significant changes in instantaneous consumption values and the mechanisms that govern this consumption. Electricity demand will increase sharply and there will be fluctuations inContinue reading “A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks”
Improving Energy Output and Efficiency of PV Installations using Bifacial Panels in Public Facilities
Published by 1. Jacek KUSZNIER, 2. Marcin SULKOWSKI, 3. Gabriela Druć, Bialystok University of Technology, Faculty of Electrical Engineering ORCID: 1. 0000-0001-8436-5717; 2. 0000-0002-3079-314X Abstract. The issue of improving the energy efficiency of photovoltaic installations is very important due to the limited location options in public facilities. Therefore, this paper presents the possibilities of improvingContinue reading “Improving Energy Output and Efficiency of PV Installations using Bifacial Panels in Public Facilities”
Thermodynamic Modelling of Waste to Energy Power Plant: A Case Study in Makassar City, Indonesia
Published by 1.Nur HAMZAH, 2.Suryanto SURYANTO, 3.Muhammad ANSHAR, 4.Firman FIRMAN, 5. Muhammad Ruswandi DJALAL, 6. Muhammad Alif AL AFGAN. State Polytechnic of Ujung Pandang ORCID: 1. 0000-0002-7114-2247 Abstract. Waste is a major problem in big cities in Indonesia, one of which is Makassar City. Every year the amount of waste generated by the residents ofContinue reading “Thermodynamic Modelling of Waste to Energy Power Plant: A Case Study in Makassar City, Indonesia”
Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network
Published by Wiktoria GRYCAN, Wroclaw University of Science and Technology, ORCID: 0000-0001-8121-7612 Abstract. Prosumerism is inherently designed to be a tool that alleviates the grid. Still, not every prosumer aligns the consumption profile with the energy generation profile in photovoltaic installations. Therefore, the rapid development of Renewable Energy Sources (RES) in Poland, especially photovoltaic installations,Continue reading “Legislative Assistance for Prosumer Energy within the Framework of Electrical Safety of Power Network”
Application Of Optical Current Sensors in Electric Substations
Published by Ilham RAHIMLI1, Aliashraf BAKHTIYAROV2, Gulshan ABDULLAYEVA3, Sona RZAYEVA4. Azerbaijan State Oil and Industry University ORCID: 1. 0009-0006-1976-4475; 3. 0000-0003-0168-9623; 4. 0000-0001-7086-9519 Abstract. Despite the fact that current transformers have been used for many years in certain sections of the electrical network, in power supply, to power the circuits of an electrical measuring installation,Continue reading “Application Of Optical Current Sensors in Electric Substations”