Published by 1. Magdalena UDZIK1, 2. Krzysztof ŁOWCZOWSKI1, 3. Józef Jacek ZAWODNIAK2,Politechnika Poznańska, Instytut Elektroenergetyki (1), Stowarzyszenie Elektryków Polskich Oddział Gorzowski (2) ORCID: 10000-0002-4959-2751.; 2. 0000-0002-4196-0492 Scopus: 3. 36620039300 Abstract. The article is the second part of the analysis of the impact of connecting PV sources to the low voltage distribution network on the riskContinue reading “Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 2: Simulation Analysis”
Tag Archives: Safety/Protection
Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 1: Characteristics of the Existing State
Published by 1. Magdalena UDZIK1, 2. Krzysztof ŁOWCZOWSKI1, 3. Józef Jacek ZAWODNIAK2, Politechnika Poznańska, Instytut Elektroenergetyki (1), Stowarzyszenie Elektryków Polskich Oddział Gorzowski (2) ORCID: 10000-0002-4959-2751.; 2. 0000-0002-4196-0492 Scopus: 3. 36620039300 Abstract. The paper presents selected issues related with MV/LV transformer stations to which local energy sources – photovoltaic power plants are connected. General parameters ofContinue reading “Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 1: Characteristics of the Existing State”
Determination of the Place and Degree of Damage Insulation in Cables
Published by Nahid MUFIDZADA1, Gulgaz İSMAYILOVA2, Azerbaijan State Oil and Industry University, Power Faculty, “Electroenergetics” department, Baku, AzerbaijanORCID: 0000-0003-4063-2128, 0000-0003-0063-2020 Abstract. A new method has been developed to determine the location and degree of insulation damage in cables. An electrical circuit is defined, using which this task is performed. According to this scheme, one endContinue reading “Determination of the Place and Degree of Damage Insulation in Cables”
Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation
Published by 1. Nuri Berisha, 2. Bahri Prebreza*, 3. Petrit Emini, Faculty of Electrical and Computer Engineering, University of PrishtinaORCID: 1. 0000-0001-8615-637X; 2. 0000-0003-1950-026X; 3. 0000-0002-2833-9001 Abstract. Power system harmonics have a significant impact on the efficiency, reliability, and stability of the system. Low power quality is determined by undervoltages and overvoltages, dips and swells,Continue reading “Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation”
PQ Secure
Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se PQ Secure – Power Quality Management System The quality of your power is extremely important as disturbances or short outages can cause major problems for your equipment and systems. We have created a Power Quality Management System that will assist you in monitoring your systemContinue reading “PQ Secure”
Unipower – About Power Quality
Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se Power quality is a generic term for disturbance-free electricity supply. Deviation from voltage sinusoidal waveform (50 Hz), which may result in equipment being disturbed or damaged, is to be regarded as a power quality disturbance. This means that the more sensitive equipment you connect toContinue reading “Unipower – About Power Quality”
Analysis of Seasonality and Causes of Equipment and Facility Failures in Electric Power Distribution Networks
Published by Andrzej Ł. CHOJNACKI, Kielce University of Technology, Department of Power Engineering ORCID: 0000-0002-9227-7538 Abstract. The article presents the results of analyses concerning the seasonality and causes of damage to equipment and facilities operated in 110kV, MV and LV power distribution networks. These facilities include 110kV overhead lines, 110kV/SN substations, MV overhead and cableContinue reading “Analysis of Seasonality and Causes of Equipment and Facility Failures in Electric Power Distribution Networks”
Harmonic Information Management System
Published by 1. Johan ADOLFSSON, Director, Unipower AB, ja@unipower.se, 2. Peter ANDERSSON, CEO, Unipower AB, psa@unipower.se, 3. Nilesh CHINTALWAR, GM, PCI Ltd, nilesh@prime-pci.in, 4. Shital SHAH, PCI Ltd, shitalshah@prime-pci.in INTRODUCTION In the vast majority of countries today there are regulations and standards implemented that specify the maximum level of harmonic content. Some countries implement theContinue reading “Harmonic Information Management System”
Transient Detection using Peak Detectors
Published by Jonny Carlsson, Unipower AB, http://www.unipower.se Background The main problem with transients in the electrical network is that a high voltage potential might break the isolation barrier in for example cables or other equipment in the electrical network. It may also harm semiconductors that are sensitive of high voltage. A transient voltage is byContinue reading “Transient Detection using Peak Detectors”
Dynamic Voltage Restorer for Voltage Unbalance Mitigation and Voltage Profile Improvement in Distribution Network
Publishd by Ahmed A. Abdullah AL-KARAKCHI1, Enaam ALBANNA2, Alya H. AL-RIFAIE3, Northern Technical University (1,2,3) ORCID: 1. 0000-0003-1151-3015; 2. 0000-0002-3974-0116; 3. 0000-0002-7978-2193 Abstract. Unbalanced network voltage damages utility and end-user equipment. Electrified trains, single-phase distributed generators, and line-toline connected industrial loads can increase voltage imbalances. Using Dynamic Voltage Restorer (DVR) at appropriate places is oneContinue reading “Dynamic Voltage Restorer for Voltage Unbalance Mitigation and Voltage Profile Improvement in Distribution Network”