PQ Secure – Power Quality Management System  

The quality of your power is extremely important as disturbances or short outages can cause major problems for your equipment and systems. We have created a Power Quality Management System that will assist you in monitoring your system performance.

The Unipower PQ Secure system is a state of the art solution for Power Quality Management and disturbance evaluation. With a user-friendly interface and intelligible functions, PQ Secure provides you with continuous remote access to all the Power Quality parameters that you need. PQ Secure is a market-leading system specifically designed for the power and energy industry, distribution, transmission and troubleshooting companies. The software is comprehensible and easy to use, being built around high-performance and automation as basic principles.

PQ Secure is fully compliant, supporting the following international standards:

• PQDIF (IEEE 1159.3)
• COMTRADE (IEC 60255-24)
• IEC 61000-4-30

The PQ Secure system is a complete Power Quality Management System. The system is modular and allows adding features both on the server side as well as on the meters. PQ Secure is designed to excel at data compression and storage, making it very fast and scalable. The system revolves around the following components: 

• Powerful evaluation tools
• Accurate statistical components
• Sortable and customisable event lists
• Data-efficient database storage solution
• Control room compatible real-time functions and much more

PQ Secure – System profile view
Advanced Power Quality Monitoring System

• Power Quality Monitoring
• IEC 61000-4-30 Class A
• Disturbance tracking
• Big Data
• Advanced real-time capabilities
• Load Demand Monitoring
• Statistics and report module
• Automatic reports
• Preventive alarms and warnings

Unipower PQ Secure – Advanced Power Quality Monitoring System

“PQ Secure provides you with continuous remote access to all the Power Quality parameters that you need.”

PQ Secure is an advanced tool that continuously scans and compiles information about your power network.

Monitors the Power Quality and reports back to you so that you can be aware of any events, anytime. Logs all critical parameters and provides you with a complete picture of the status in the power network.

.
Profile View – Evaluate Multiple PQ Meters Simultaneously

“Identify opportunities, verify savings”

PQ Secure is designed to easily combine information received from both permanent and portable PQ meters and store it in the same Power Quality System.

All Unipower PQ meters are configured using a singular system – PQ Online – and all data is downloaded and evaluated using one platform – PQ Secure.Profile View – Evaluate Multiple PQ Meters Simultaneously

PQ Secure – Tag your meters using attributes for fast and correct selection
Determine trends and create statistics – using data gathered over more than 20 years
Automatic tracking of disturbances
Monitor your Operations in Real-time

“Maximise electrical network reliability and availability.”

Real-time monitoring enables the user to connect directly to a PQ meter and monitor selected parameters without delay.

PQ Secure – Example of real-time view
Automatic Reports

“Increase energy efficiency and cost savings.”

Unipower provides you with the possibility to create customisable reports that match your specific requirements and national requirements.

Design your own reports directly from PQ Secure or simply select one of the ready-made, normative, local or special reports you wish to generate.

You can also schedule specific reports to be automatically and periodically generated.

.

About Unipower: Unipower AB offers a wide range of products for Power Quality measurements and Smart Grid systems.

Originating from a Swedish ABB company in the mid 80’s, Unipower has developed a competitive edge within the field of Power Quality and Smart-Grid solutions. We focus on norm compliance equipment, with a special focus on the requirements for power generation, transmission and distribution.

Our product lines reach from traditional portable PQ analysers to fully integrated and automated Power Quality Management systems for continuous supervision of the energy supply.

Website: unipower.se

Published by PQBlog

Electrical Engineer

Leave a Reply