What Makes a Power Quality Problem Worth Solving?

Published by Dranetz Technologies, Inc. Tech Tip: What Makes a Power Quality Problem Worth Solving?, Website: Dranetz.com  Most power quality events won’t shut you down. But when they do, they cost more than just a headache. The challenge isn’t detecting power quality problems. That’s the easy part. The real question is: Do those issues actually matter to your operation? AContinue reading “What Makes a Power Quality Problem Worth Solving?”

Manage Your Energy Expenses

Published by Dranetz Technologies, Inc., Case Study Utility energy and demand costs have a direct impact on a company’s bottom line. In fact, a typical commercial or industrial facility can save from 10% to as much as 35% annually on energy costs by implementing a comprehensive energy management plan. And while each facility will require an organizedContinue reading “Manage Your Energy Expenses”

Thickness Measurement System for Testing the Condition of Protective Layers of Power Equipment

Published by Paweł PTAK1, Tomasz PRAUZNER2, Henryk NOGA3, Piotr MIGO3, Agnieszka Gajewska3, Politechnika Częstochowska, Katedra Automatyki, Elektrotechniki i Optoelektroniki (1), Uniwersytet Jana Długosza w Częstochowie, Katedra Pedagogiki (2), Uniwersytet Pedagogiczny w Krakowie, Instytut Nauk Technicznych (3) Abstract. The paper presents a study on an electromagnetic inductive sensor for detecting and locating faults in protective coatings.Continue reading “Thickness Measurement System for Testing the Condition of Protective Layers of Power Equipment”

Planning and Performing a Power Quality Survey

Published by Dranetz Technologies, Support – Technical Documents, Application Note, website: dranetz.com, 800-372-6832 (U.S & Canada) +1-732-287-3680 (International). INTRODUCTION The power quality survey is the first, and perhaps most important, step in identifying and solving power problems. Power problems can harm equipment performance and reduce reliability, lower productivity and profitability, and even pose personnel safetyContinue reading “Planning and Performing a Power Quality Survey”

Identification of Electric Field Strength in Aircrafts

Published by 1. Joanna MICHAŁOWSKA1, 2. Paweł TOMIŁO2, 3. Jarosław PYTKA2, 4. Łukasz PUZIO1, 5. Arkadiusz TOFIL1, The University College of Applied Science in Chelm (1), Lublin University of Technology (2) ORCID: 1.0000-0002-2353-6305, 2. 0000-0003-4461-3194, 3. 0000-0002-5474-3585, 4. 0000-0002-7116-8586, 5. 0000-0003-2392-6597 Abstract. The development of new technologies contributes to an increase in the value ofContinue reading “Identification of Electric Field Strength in Aircrafts”

A New Approach to Cross-Bonding in Medium Voltage Cable Lines

Published by Jacek KLUCZNIK, Gdansk University of Technology, Faculty of Electrical and Control Engineering. ORCID: 0000-0002-2328-9180 Abstract. The medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused byContinue reading “A New Approach to Cross-Bonding in Medium Voltage Cable Lines”

PQ Secure

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se PQ Secure – Power Quality Management System   The quality of your power is extremely important as disturbances or short outages can cause major problems for your equipment and systems. We have created a Power Quality Management System that will assist you in monitoring your systemContinue reading “PQ Secure”

Ultra–Fast Charging of Electric Bus Fleet and its Impact on Power Quality Parameters

Published by 1. Aleksander CHUDY, 2. Paweł A. MAZUREK, Lublin University of Technology ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. The research focused on one–week long measurement of power quality parameters at the connection point of a 450 kW charging station (pantograph type) in the distribution substation. The bus terminal was equipped with 1200 kVA 15.75/0.42Continue reading “Ultra–Fast Charging of Electric Bus Fleet and its Impact on Power Quality Parameters”

Analysis of Seasonality and Causes of Equipment and Facility Failures in Electric Power Distribution Networks

Published by Andrzej Ł. CHOJNACKI, Kielce University of Technology, Department of Power Engineering ORCID: 0000-0002-9227-7538 Abstract. The article presents the results of analyses concerning the seasonality and causes of damage to equipment and facilities operated in 110kV, MV and LV power distribution networks. These facilities include 110kV overhead lines, 110kV/SN substations, MV overhead and cableContinue reading “Analysis of Seasonality and Causes of Equipment and Facility Failures in Electric Power Distribution Networks”

Differences between IEC and IEEE Standards of Transformers

Published by Indi. Wang Focus on the transformers | Electrical transformer business developer | With IEC authentication CE ISO9001:2000 Hefei, Anhui, China When it comes to adding or replacing transformers in oil and gas plants, operators need to consider various factors to optimize their operations. In this article, we will explore the differences between theContinue reading “Differences between IEC and IEEE Standards of Transformers”