Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 1: Characteristics of the Existing State

Published by 1. Magdalena UDZIK1, 2. Krzysztof ŁOWCZOWSKI1, 3. Józef Jacek ZAWODNIAK2, Politechnika Poznańska, Instytut Elektroenergetyki (1), Stowarzyszenie Elektryków Polskich Oddział Gorzowski (2) ORCID: 10000-0002-4959-2751.; 2. 0000-0002-4196-0492 Scopus: 3. 36620039300 Abstract. The paper presents selected issues related with MV/LV transformer stations to which local energy sources – photovoltaic power plants are connected. General parameters ofContinue reading “Connection of Photovoltaic Sources to the Low Voltage Distribution Network vs. Risk of Overloading the Transformer Station. Part 1: Characteristics of the Existing State”

Analysing the Performance of H5 Inverters in a Photovoltaic System

Published by 1. Mohd Sanusi Bin Mohd Mokhtar1, 2. Mohd Shafie Bin Bakar2, 3. Mohd Shawal Bin Jadin2, Paya Besar Community College (1), Faculty of Electrical and Electronics Engineering Technology, Universiti Malaysia Pahang (UMP) (2) ORCID: 2. 0000-0003-2905-6449; 3.0000-0001-6253-7821 Abstract. In this paper, a simulation study on H5 topology is presented. H5 topology is aContinue reading “Analysing the Performance of H5 Inverters in a Photovoltaic System”

Electricity Transportation using HVDC Technology for Algerian Southern Sun Power Plants

Published by 1. Mohammed SAAIDIA, 2. Abdelghani GUECHI, 3. Nedjem-Eddine BENCHOUIA, University Mohamed-Cherif Messaadia of Souk-Ahras . ORCID: 1. 0000-0002-7778-8591; 3. 0000-0002-4761-940 Abstract. Algeria is worldly known as one of the big producers and exporters of fossil fuels. However, by developing an adequate energy policy, it could become one of the great sun power (SP)Continue reading “Electricity Transportation using HVDC Technology for Algerian Southern Sun Power Plants”

Determination of the Place and Degree of Damage Insulation in Cables

Published by Nahid MUFIDZADA1, Gulgaz İSMAYILOVA2, Azerbaijan State Oil and Industry University, Power Faculty, “Electroenergetics” department, Baku, AzerbaijanORCID: 0000-0003-4063-2128, 0000-0003-0063-2020 Abstract. A new method has been developed to determine the location and degree of insulation damage in cables. An electrical circuit is defined, using which this task is performed. According to this scheme, one endContinue reading “Determination of the Place and Degree of Damage Insulation in Cables”

Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation

Published by 1. Nuri Berisha, 2. Bahri Prebreza*, 3. Petrit Emini, Faculty of Electrical and Computer Engineering, University of PrishtinaORCID: 1. 0000-0001-8615-637X; 2. 0000-0003-1950-026X; 3. 0000-0002-2833-9001 Abstract. Power system harmonics have a significant impact on the efficiency, reliability, and stability of the system. Low power quality is determined by undervoltages and overvoltages, dips and swells,Continue reading “Power Quality Analysis: Case Study for Induction Motor and 110/35kV Substation”

Analysis of Annual Load Variability in the Polish Electric Power System

Published by Kornelia BANASIK1, Andrzej Ł. CHOJNACKI2, Agata KAŹMIERCZYK3, Kielce University of Technology, Faculty of Electrical Engineering, Automatic Control and Computer Science, Department of Power Engineering, Power Electronics and Electrical MachinesORCID: 1. 0000-0002-6629-8650; 2.0000-0002-9227-7538; 3. 0000-0002-4247-4904 Abstract: The paper presents an analysis of the annual variability of power system loads in Poland over a periodContinue reading “Analysis of Annual Load Variability in the Polish Electric Power System”

PQ Secure

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se PQ Secure – Power Quality Management System   The quality of your power is extremely important as disturbances or short outages can cause major problems for your equipment and systems. We have created a Power Quality Management System that will assist you in monitoring your systemContinue reading “PQ Secure”

Ultra–Fast Charging of Electric Bus Fleet and its Impact on Power Quality Parameters

Published by 1. Aleksander CHUDY, 2. Paweł A. MAZUREK, Lublin University of Technology ORCID: 1. 0000-0002-3183-8450, 2. 0000-0002-7098-2084 Abstract. The research focused on one–week long measurement of power quality parameters at the connection point of a 450 kW charging station (pantograph type) in the distribution substation. The bus terminal was equipped with 1200 kVA 15.75/0.42Continue reading “Ultra–Fast Charging of Electric Bus Fleet and its Impact on Power Quality Parameters”

Unipower – About Power Quality

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se Power quality is a generic term for disturbance-free electricity supply. Deviation from voltage sinusoidal waveform (50 Hz), which may result in equipment being disturbed or damaged, is to be regarded as a power quality disturbance. This means that the more sensitive equipment you connect toContinue reading “Unipower – About Power Quality”