Published by Houria SMAIL1, Yassine BENSAFIA2, PaElectrical Engineering Department, Faculty of Sciences and Applied sciences, University of Bouira, 10000 – Algeria (1), PaElectrical Engineering Department, Faculty of Sciences and Applied sciences, University of Bouira, 10000 – Algeria (2), ORCID: 1. 0000-0001-8474-2009; 2. 0000-0003-1760-3636 Abstract. Depending on the power system condition in terms of operating reserves,Continue reading “A New Approach for Load shedding Scheme”

Flexible Rogowski Current Probes in Measurements of Ultra-Fast SiC MOSFET Modules – Limitations and Challenges

Published by Dawid ZIĘBA1, Jacek RĄBKOWSKI2, Medcom Company (1), Warsaw University of Technology, Institute of Control and Industrial Electronics (2) ORCID: 1. 0000-0003-3789-6851; 2. 0000-0001-8857-3505 Abstract. The article presents a discussion on the limitations of the flexible Rogowski current probes in the measurements of switching processes in ultra-fast SiC MOSFET power modules. The probes featureContinue reading “Flexible Rogowski Current Probes in Measurements of Ultra-Fast SiC MOSFET Modules – Limitations and Challenges”

Prognosis of Insulation Deterioration in Induction Motors Winding Subject to Voltage Fluctuations

Published by 1. Ilham Bouaissi1, 2. Ali Rezig1, 3. Said Touati2, L2EI Laboratory, University Mohammed Seddik Benyahia, Ouled Aissa. Bp 98, Jijel, 18000, Algeria (1). Nuclear research center, Birine, Ain Oussera. Bp 180, Djelfa, 17200 Algeria (2) ORCID: 1. 0000-0001-5981-6918 Abstract. One of the problems with induction motors, say the experts, is voltage. Insulation deteriorationContinue reading “Prognosis of Insulation Deterioration in Induction Motors Winding Subject to Voltage Fluctuations”

Residual Current Devices in Electric Vehicles Charging Installations

Published by Stanislaw CZAPP, Gdańsk University of Technology, ORCID: 0000-0002-1341-8276 Abstract. The main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment forContinue reading “Residual Current Devices in Electric Vehicles Charging Installations”

Research of Methods Power Control of Wind Turbines

Published by Nijat Mammadov1, Ilkin Marufov2, Saadat Shikhaliyeva, Gulnara Aliyeva, Saida Kerimova,Azerbaijan State Oil and Industry UniversityORCID: 1. 0000-0001-6555-3632; 2. 0000-0002-3143-0113 Abstract. Currently, renewable energy sources play an important role in the global energy balance. Among them, wind electric installations occupy a special place. As wind turbines develop and their power increases, their design alsoContinue reading “Research of Methods Power Control of Wind Turbines”

Power Quality Measurements from the Spain – Portugal Blackout

Published by Mr. Thomas Ottosson, Managing Director, Unipower AB, Sweden. Email: thomas.ottosson@unipower.se . Website: unipower.se Source URL: https://pqsynergy.com/assets/files/Power-QualityMeasurementsfromtheSpainPortugalBlackout.pdf

UNIPOWER IEC 61000-4-30 Ed. 4

Published by Mr. Jonny Carlsson, Research Manager, Unipower AB, Sweden. Email: jonny.carlsson@unipower.se . Website: unipower.se Source URL: https://pqsynergy.com/assets/files/UNIPOWER-IEC61000-4-30Ed.4InprogressstateFDISMemberofWG9.pdf

Protection of DC Microgrid using ΔCB

Published by 1. Marwan R. Abed, 2. Oday A. Ahmed, 3. Ghassan A. Bilal, University of Technology Iraq, Baghdad, ORCID: 1. 0000-0002-1257-2810; 2. 0000-0001-7214-3412; 3. 0000-0002-5090-103X Abstract. When implementing a DC distribution network, it is much easier to integrate distributed energy sources than it is with an ac grid. Furthermore, the efficiency and reliability ofContinue reading “Protection of DC Microgrid using ΔCB”

Thickness Measurement System for Testing the Condition of Protective Layers of Power Equipment

Published by Paweł PTAK1, Tomasz PRAUZNER2, Henryk NOGA3, Piotr MIGO3, Agnieszka Gajewska3, Politechnika Częstochowska, Katedra Automatyki, Elektrotechniki i Optoelektroniki (1), Uniwersytet Jana Długosza w Częstochowie, Katedra Pedagogiki (2), Uniwersytet Pedagogiczny w Krakowie, Instytut Nauk Technicznych (3) Abstract. The paper presents a study on an electromagnetic inductive sensor for detecting and locating faults in protective coatings.Continue reading “Thickness Measurement System for Testing the Condition of Protective Layers of Power Equipment”

400Hz Monitoring – Aviation Applications

Published by Dranetz Technologies, Inc., Application Note INTRODUCTION Most of the world distributes power at 50Hz or 60Hz. However, there are certain specialized applications that distribute power at other frequencies. Applications such as aviation, naval, and others distribute power at 400Hz to improve system efficiencies. 400Hz applications can be a challenge for the end user since mostContinue reading “400Hz Monitoring – Aviation Applications”