Published by Dranetz Technologies, Inc., Case Study With the proliferation of Compact Florescent (CF) lighting, we thought it would be interesting to do a side by side comparison to an incandescent bulb using our new Energy Platform EP1. Not only is it a great demonstration of the capabilities of the EP1 but it’s also an opportunity toContinue reading “Comparison of Compact Fluorescent to Incandescent Bulbs”
Tag Archives: Dranetz
Glass Factory Failure of Electronic Controls
Published by Dranetz Technologies, Inc., Case Study The customer was experiencing repeated failures electronic controls and instruments in a new glass factory. The factory had been imported from a 60hz country to a 50hz country. In this case, the new factory capacity was reduced by 50% or more do the frequent shut downs and stoppages. The costContinue reading “Glass Factory Failure of Electronic Controls”
The Critical Role of Power Quality Evaluation in Solar Installations
Published by Dranetz Technologies, Inc., Application Note EXECUTIVE SUMMARY As solar photovoltaic (PV) systems become more prevalent in commercial and industrial environments, the emphasis on financial return and concise performance expectations has rightly intensified. However, one often-overlooked aspect of solar deployment is the comprehensive evaluation of power quality (PQ)—both before and after installation. By identifying existing gridContinue reading “The Critical Role of Power Quality Evaluation in Solar Installations”
Planning and Performing a Power Quality Survey
Published by Dranetz Technologies, Support – Technical Documents, Application Note, website: dranetz.com, 800-372-6832 (U.S & Canada) +1-732-287-3680 (International). INTRODUCTION The power quality survey is the first, and perhaps most important, step in identifying and solving power problems. Power problems can harm equipment performance and reduce reliability, lower productivity and profitability, and even pose personnel safetyContinue reading “Planning and Performing a Power Quality Survey”
Wind Plant IEEE Std. 519 Compliance Evaluation
Published by Electrotek Concepts, Inc., PQSoft Case Study: Wind Plant IEEE Std. 519 Compliance Evaluation, Document ID: PQS1201, Date: January 25, 2012. Abstract: This case study presents the results for a wind plant substation IEEE Std. 519 harmonic measurement compliance evaluation. The wind plant substation supplied 65 wind turbine generators and the power quality monitor wasContinue reading “Wind Plant IEEE Std. 519 Compliance Evaluation”
Dranetz Encore System monitoring BNL/BP Solar Photovoltaic (PV) Plant
Variable Frequency Drive (VFD) Testing Applications
Published by Dranetz Technologies, Inc. VFD motor controls have become very popular for both retrofits and in new applications. They offer increased energy efficiency, potential for less motor wear, lower startup currents and more. Potential disadvantageous include producing harmonics and damaged motors if they are not controlled properly. VFD’s use a Pulse Width Modulated (PWM) voltageContinue reading “Variable Frequency Drive (VFD) Testing Applications”
Dranetz HDPQ Family Generator & Mission Critical Testing
Published by Dranetz Technologies, Inc. INTRODUCTION Data centers, hospitals, mission critical and other facilities rely on standby power. This is often generators that are ready to carry the load if there is an interruption in the primary power source. Such facilities often have UPS systems for a seamless transition to standby power, and to carry theContinue reading “Dranetz HDPQ Family Generator & Mission Critical Testing”
Energy Platform EP1 Trend Data Time Interval
Published by Terry Chandler, Director of Engineering, Power Quality (Thailand) Co., Ltd. Emails: terryc@powerquality.co.th,TChandler@Dranetz.com The EP1 is Energy Platform has a slightly different time interval for the trended data from the other Dranetz portable products. The PX/PG/PV have a minimum intervals of 1 second, 10 seconds and 1 minute. Note: There are some limitations onContinue reading “Energy Platform EP1 Trend Data Time Interval”
Dranetz HDPQ Generator & Mission Critical Applications
Load stepping, power source switching and other tests required during the commissioning and troubleshooting of mission critical facilities presents unique challenges to the average PQ analyzer, but Dranetz doesn’t make average PQ analyzers. Most PQ analyzers can’t reliably capture the step load changes, don’t have a large enough recording buffer, can’t capture the effects onContinue reading “Dranetz HDPQ Generator & Mission Critical Applications”