Published by Dranetz Technologies, Inc. VFD motor controls have become very popular for both retrofits and in new applications. They offer increased energy efficiency, potential for less motor wear, lower startup currents and more. Potential disadvantageous include producing harmonics and damaged motors if they are not controlled properly. VFD’s use a Pulse Width Modulated (PWM) voltageContinue reading “Variable Frequency Drive (VFD) Testing Applications”
Tag Archives: Dranetz
Dranetz HDPQ Family Generator & Mission Critical Testing
Published by Dranetz Technologies, Inc. INTRODUCTION Data centers, hospitals, mission critical and other facilities rely on standby power. This is often generators that are ready to carry the load if there is an interruption in the primary power source. Such facilities often have UPS systems for a seamless transition to standby power, and to carry theContinue reading “Dranetz HDPQ Family Generator & Mission Critical Testing”
Energy Platform EP1 Trend Data Time Interval
Published by Terry Chandler, Director of Engineering, Power Quality (Thailand) Co., Ltd. Emails: terryc@powerquality.co.th,TChandler@Dranetz.com The EP1 is Energy Platform has a slightly different time interval for the trended data from the other Dranetz portable products. The PX/PG/PV have a minimum intervals of 1 second, 10 seconds and 1 minute. Note: There are some limitations onContinue reading “Energy Platform EP1 Trend Data Time Interval”
Dranetz HDPQ Generator & Mission Critical Applications
Load stepping, power source switching and other tests required during the commissioning and troubleshooting of mission critical facilities presents unique challenges to the average PQ analyzer, but Dranetz doesn’t make average PQ analyzers. Most PQ analyzers can’t reliably capture the step load changes, don’t have a large enough recording buffer, can’t capture the effects onContinue reading “Dranetz HDPQ Generator & Mission Critical Applications”
Harmonics & Waveform Measurements Low Pass Filter & Sine Wave Filter for a 460V 100HP AC Motor with VFD
Published by Dranetz™ Technologies, Inc., Case Study, Website: dranetz.com. This case study was submitted by Ing. Leopoldo Martínez Basulto, Dranetz México. INTRODUCTION Harmonics are an important PQ issue today. Variable Frequency Drives (VFD), Uninterruptible Power Systems (UPS), computers, LED lighting, electronic ballasts, etc. are widely used in all kinds of facilities. It is well knownContinue reading “Harmonics & Waveform Measurements Low Pass Filter & Sine Wave Filter for a 460V 100HP AC Motor with VFD”
Measured Parameters of All HDPQ Models
Published by Dranetz, Website: Dranetz.com Measured Parameters of All HDPQ Models: Xplorer, Guide, Visa, SP and HDPQ DataNode
PQ Analysis: Power Quality Reports
Published by testguy, November 23, 2019. Website: testguy.net Power Quality Reports A power quality meter can plot the voltage and current waveforms as functions of time, this is called an oscillogram. Data can be extracted from the power quality recorder and analyzed to determine the overall condition of the power system using various timeplots and tables. TheContinue reading “PQ Analysis: Power Quality Reports”
Dran-View 7 Software
Published by Dranetz Our instruments are great, but Dran-View 7 software makes them better! Much more than just a viewer, Dran-View adds value to any power survey. Used by tens of thousands of power professionals, Dran-View is included with most of our portable instrument packages, including HDPQ and DranXperT: Easily see recorded trends & eventContinue reading “Dran-View 7 Software”
Dranetz Announces Flex CT’s For DranXperT!
Dranetz is pleased to announce the addition of Flex CT’s to DranXperT. DranXperT is a low cost, 3-phase power & energy logger for use in virtually any power logging application. With the addition of Flex CT’s, DranXperT now offers the widest range of CT choices on the market. DranXperT’s capabilities includes: High accurate power &Continue reading “Dranetz Announces Flex CT’s For DranXperT!”
DV6 & DV7 Harmonics Post-Processing
Published By Terry Chandler Director of Engineering, Power Quality Thailand LTD/Power Quality Inc., USA. Emails: terryc@powerquality.org, terryc@powerquality.co.th