Published by 1. Sahapong SOMWONG1, 2. Kritsada PUANGSUWAN2,Faculty of Engineering, Rajamangala University of Technology Srivijaya Songkhla, Thailand (1),Faculty of Science and Industrial Technology, Prince of Songkla University, Surat Thani Campus, Surat Thani, Thailand (2) ORCID: (1) 0000-0002-2693-494X; (2) 0000-0003-1613-0611 Abstract. This paper reports the study to design and develop a system for controlling and displayingContinue reading “Power Consumption Control and Monitor using IoT Platform for Smart Office”
Yearly Archives: 2025
What Caused the Big Blackout in Spain and Portugal?
Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se On 28 April 2025, at 12:33 CET, the power systems of Spain and Portugal experienced a total blackout. Investigation is still in progress. Above and below is 30 minutes of high-resolution waveform data we could extract from a meter in the Portuguese grid. We couldContinue reading “What Caused the Big Blackout in Spain and Portugal?”
Impact of Renewable Resources Penetration on Maximum Loading Point and Dynamic Voltage Stability
Published by 1. Benalia Nadia1, 2. Ben Si Ali Nadia1, 3.Zerzouri Nora1, Badji Mokhtar Annaba University B.P 2300 Annaba Algeria. ORCID: 1. 0000-0003-4819-5313; 2. 0000-0001-7248-4823; 3. 0000-0003-1209-4617 Abstract. This paper presents the impact of a grid-connected photovoltaic (PV) generator with a wind turbine on dynamic voltage stability and maximum loading point by considering the PV-windContinue reading “Impact of Renewable Resources Penetration on Maximum Loading Point and Dynamic Voltage Stability”
High impedance Fault Detection in Low Voltage Overhead Distribution based Wavelet and Harmonic Indices
Published by Enaam ALBANNA1, Alya H. AL-RIFAIE2, Ahmed A. Abdullah AL-KARAKCHI3, Northern Technical University (1,2,3) ORCID: 1. 0000-0002-3974-0116; 2. 0000-0002-7978-2193; 3. 0000-0003-1151-3015; Abstract. High-impedance fault HIF occurs when an energized conductor makes contact with a surface with a high impedance. Conventional overcurrent protection cannot detect this fault due to the low fault current, and thereContinue reading “High impedance Fault Detection in Low Voltage Overhead Distribution based Wavelet and Harmonic Indices”
Communication Research of Protective Relays for Microgrids and Active Distribution Networks
Published by 1. Róbert Štefko1, Zsolt Čonka1, Michal Kolcun, 2. Viktor Jurák2, 3. Judith Pálfi3, Technical University of Košice (1), Brno University of Technology (2), Óbuda University (3) ORCID: 1. 0000-0002-2477-4559, 0000-0001-6620-4354, 0000-0002-8041-9076; 2. 0000-0002-6832-7654 Abstract. The penetration of renewable energy sources into the electricity distribution network causes changes in power flows, making conventional protectionContinue reading “Communication Research of Protective Relays for Microgrids and Active Distribution Networks”
Design PV Power System: A Case Between Two Different Types of Solar Modules
Published by 1. Ali N. Hamoodi1, 2. Waseem Kh. Ibrahim2, 3. Aseel Thamer Ebrahem3, Northern Technical University (1), Northern Technical University (2), Northern Technical University (3)ORCID: 1. 0000-0003-0991-3538; 2. 0000-0002-9126-7872; 3. 0000-0002-1090-0454 Abstract. A photovoltaic (PV) is a technical terminology that is used to generate electricity from sunlight. Solar energy is one of the solutionsContinue reading “Design PV Power System: A Case Between Two Different Types of Solar Modules”
Presentation Harmonics Distortion of Power Waveforms Signals
Published by Małgorzata ZYGARLICKA1, Jarosław ZYGARLICKI2, Politechnika Opolska, Instytut Automatyki i Informatyki (1) Politechnika Opolska, Instytut Elektroenergetyki i Energii Odnawialnej (2) Abstract. The paper presents a new proposal for the presentation of the harmonic distortion of the power signals. The proposed method uses a simplified method of harmonic analysis – five ordinates method by whichContinue reading “Presentation Harmonics Distortion of Power Waveforms Signals”
Optimization of Field Upgrades of MV Power Lines using Evolutionary Algorithms
Published by Wojciech NITA1, Sylwester FILIPIAK2, PGE Dystrybucja S.A. Oddział Skarżysko-Kamienna (1), Politechnika Świętokrzyska (2) Abstract. This article elaborates on and supplements the research presented in earlier works [19,20,21] on planning for upgrading field MV power grids. While that study developed models for optimizing failure rates (SAIFI, SAIDI, MAIFI) for large areas of the grid,Continue reading “Optimization of Field Upgrades of MV Power Lines using Evolutionary Algorithms”
Generation of High-Voltage Solitons in a Non-Linear Transmission Line
Published by 1. Andrzej FARYŃSKI1, 2. Zbigniew ZIÓŁKOWSKI1, 3. Przemysław SUL2, Air Force Institute of Technology (AFIT) (1), Warsaw University of Technology (2)ORCID: 1. 000-0008-1232-2747; 2. 000-0002-7713-0271; 3. 0000-0002-4327-9334 Abstract. The article describes research, the main aim of which was to present the method of generating high-voltage impulses – solitons using a non-linear NLTL transmissionContinue reading “Generation of High-Voltage Solitons in a Non-Linear Transmission Line”
Increasing Transmission Potential of 110 kV Alternating Current Lines
Published by Jacek KOZYRA, Zbigniew ŁUKASIK, Aldona KUŚMIŃSKA-FIJAŁKOWSKA, Kazimierz Pulaski University of Technology and Humanities in Radom, Faculty of Transport, Electrical Engineering and Computer Science. ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031 Abstract. Construction of new power lines is a complicated and long-lasting formal and legal process. The duration of the investments is extended byContinue reading “Increasing Transmission Potential of 110 kV Alternating Current Lines”