Published by Mahmood T. Alkhayyat1, Laith A. Khalaf2, Mohammed Y. Suliman3, Northern Technical University. ORCID: 1. 0000-0001-6119-7845; 2. 0000-0003-1602-6152; 3. 0000-0002-1250-6362 Abstract. A special form of energy system that can be utilized to provide all the energy needed in the globe is the renewable hybrid system. In order to successfully use renewable energy and decreaseContinue reading “Adaptive Control for Power Management Based on Renewable Energy”
Tag Archives: solar-power
Increasing Penetration of Renewable Sources into Power System in Poland
Published by Tomasz SIEŃKO1, Jerzy SZCZEPANIK2, Cracow University of Technology, Krakow Poland (1), Cracow University of Technology, Krakow Poland (2) ORCID: 1. 0000-0002-3645-5694; 2. 0000-0001-5633-8359 Abstract. Increased Penetration of the Polish Power Supply System by renewable sources (RES) leads to a number of serious and new problems. The problems are associated with evacuating energy fromContinue reading “Increasing Penetration of Renewable Sources into Power System in Poland”
The Critical Role of Power Quality Evaluation in Solar Installations
Published by Dranetz Technologies, Inc., Application Note EXECUTIVE SUMMARY As solar photovoltaic (PV) systems become more prevalent in commercial and industrial environments, the emphasis on financial return and concise performance expectations has rightly intensified. However, one often-overlooked aspect of solar deployment is the comprehensive evaluation of power quality (PQ)—both before and after installation. By identifying existing gridContinue reading “The Critical Role of Power Quality Evaluation in Solar Installations”
Project of a Stratospheric Photovoltaic Power Station
Published by Stanisław BEDNAREK, Department of Physics and Applied Informatics, University of Łódź Abstract. The aim of this article is to present an innovative concept, concerning the design of a photovoltaic power plant located in the stratosphere. The most important advantage of this location is the increased access to solar energy, which can be convertedContinue reading “Project of a Stratospheric Photovoltaic Power Station”
A Novel Method to Improve the Power Quality Via Hybrid System
Published by 1. Raghad Adeeb Othman1, 2. Omar Sh. Alyozbaky2,Department of Electrical Engineering, College of Engineering, University of Mosul, Iraq (1,2)ORCID: 1. 0000-0001-5875-9210; 2. 0000-0002-9735-1469 Abstract. Ever increasing electricity demand as well as the rapid depletion of fossil fuels have increased the need for hybrid power systems that integrate distributed energy resource (DER) systems; suchContinue reading “A Novel Method to Improve the Power Quality Via Hybrid System”
Impact of Renewable Resources Penetration on Maximum Loading Point and Dynamic Voltage Stability
Published by 1. Benalia Nadia1, 2. Ben Si Ali Nadia1, 3.Zerzouri Nora1, Badji Mokhtar Annaba University B.P 2300 Annaba Algeria. ORCID: 1. 0000-0003-4819-5313; 2. 0000-0001-7248-4823; 3. 0000-0003-1209-4617 Abstract. This paper presents the impact of a grid-connected photovoltaic (PV) generator with a wind turbine on dynamic voltage stability and maximum loading point by considering the PV-windContinue reading “Impact of Renewable Resources Penetration on Maximum Loading Point and Dynamic Voltage Stability”
Design PV Power System: A Case Between Two Different Types of Solar Modules
Published by 1. Ali N. Hamoodi1, 2. Waseem Kh. Ibrahim2, 3. Aseel Thamer Ebrahem3, Northern Technical University (1), Northern Technical University (2), Northern Technical University (3)ORCID: 1. 0000-0003-0991-3538; 2. 0000-0002-9126-7872; 3. 0000-0002-1090-0454 Abstract. A photovoltaic (PV) is a technical terminology that is used to generate electricity from sunlight. Solar energy is one of the solutionsContinue reading “Design PV Power System: A Case Between Two Different Types of Solar Modules”
Enhancing the Solar PV Plant Based on Incremental Optimization Algorithm
Published by 1. Ali N. HAMOODI1, 2. Safwan A. HAMOODI2, 3. Farah I. HAMEEDI3, Northern Technical University (1), Northern Technical University (2), Northern Technical University (3), IraqORCID: 1. 0000-0003-0991-3538; 2. 0000-0001-9346-5680; 3. 0000-0003-1742-6959 Abstract. Photovoltaic systems are impacted by the quantity and temperature of sunshine. Due to the competing nature of solar radiation, PV systemsContinue reading “Enhancing the Solar PV Plant Based on Incremental Optimization Algorithm”
Heuristic Optimization of PV Energy Penetration to Resilience System Frequency Fluctuation
Published by 1. Afaneen Anwer Abbood1, 2. Hanan Mikhael D. Habbi2, University of Technology-Iraq, Baghdad, (1) , University of Baghdad, Dept. Of Electrical Engineering, Baghdad, Iraq (2)ORCID: 1. 0000-0003-3995-8307; 2. 0000-0003-4982-4345 Abstract. Renewable energy can make the utility grid unstable by causing some problems, such as frequency fluctuations, voltage surges, and power instability because ofContinue reading “Heuristic Optimization of PV Energy Penetration to Resilience System Frequency Fluctuation”
The Solar Photovoltaic Energy Capacity for a Parking Project at USTO University
Published by Nessim Abderrahim BOURAHLA1, Mustapha BENGHANEM2, Hamid BOUZEBOUDJA2, Abed BOUADI2, Ali TAHRI2, Higher school of electrical and energy engineering of ran,’’ESGEE’’,Oran, Algeria (1), University of Science and Technology of Oran,’’USTO-MB’’, Oran, Algeria (2)ORCID: 1. 0009-0001-1479-1355 Abstract. A notable shift towards incorporating decentralized energy resources into electrical grids is currently in progress. This article conductsContinue reading “The Solar Photovoltaic Energy Capacity for a Parking Project at USTO University”