400Hz Monitoring – Aviation Applications

Published by Dranetz Technologies, Inc., Application Note INTRODUCTION Most of the world distributes power at 50Hz or 60Hz. However, there are certain specialized applications that distribute power at other frequencies. Applications such as aviation, naval, and others distribute power at 400Hz to improve system efficiencies. 400Hz applications can be a challenge for the end user since mostContinue reading “400Hz Monitoring – Aviation Applications”

2 Week Energy Survey

Published by Dranetz Technologies, Inc., Case Study Willows Swim Club is a private, member-owned swimming and recreational facility located in central New Jersey. The swim club provides kitchen space to a local restaurant to operate a food concession. Being offered as a service to its membership, there is presently no charge for rent or utilities. However, givenContinue reading “2 Week Energy Survey”

Comparison of Compact Fluorescent to Incandescent Bulbs

Published by Dranetz Technologies, Inc., Case Study With the proliferation of Compact Florescent (CF) lighting, we thought it would be interesting to do a side by side comparison to an incandescent bulb using our new Energy Platform EP1. Not only is it a great demonstration of the capabilities of the EP1 but it’s also an opportunity toContinue reading “Comparison of Compact Fluorescent to Incandescent Bulbs”

Glass Factory Failure of Electronic Controls

Published by Dranetz Technologies, Inc., Case Study The customer was experiencing repeated failures electronic controls and instruments in a new glass factory. The factory had been imported from a 60hz country to a 50hz country. In this case, the new factory capacity was reduced by 50% or more do the frequent shut downs and stoppages. The costContinue reading “Glass Factory Failure of Electronic Controls”

Power Consumption Control and Monitor using IoT Platform for Smart Office

Published by 1. Sahapong SOMWONG1, 2. Kritsada PUANGSUWAN2,Faculty of Engineering, Rajamangala University of Technology Srivijaya Songkhla, Thailand (1),Faculty of Science and Industrial Technology, Prince of Songkla University, Surat Thani Campus, Surat Thani, Thailand (2) ORCID: (1) 0000-0002-2693-494X; (2) 0000-0003-1613-0611 Abstract. This paper reports the study to design and develop a system for controlling and displayingContinue reading “Power Consumption Control and Monitor using IoT Platform for Smart Office”

Planning and Performing a Power Quality Survey

Published by Dranetz Technologies, Support – Technical Documents, Application Note, website: dranetz.com, 800-372-6832 (U.S & Canada) +1-732-287-3680 (International). INTRODUCTION The power quality survey is the first, and perhaps most important, step in identifying and solving power problems. Power problems can harm equipment performance and reduce reliability, lower productivity and profitability, and even pose personnel safetyContinue reading “Planning and Performing a Power Quality Survey”

PQ Secure

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se PQ Secure – Power Quality Management System   The quality of your power is extremely important as disturbances or short outages can cause major problems for your equipment and systems. We have created a Power Quality Management System that will assist you in monitoring your systemContinue reading “PQ Secure”

Choosing The Right Equipment

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se What do you need to measure? Power quality is assessed based on a number of power quality parameters. Today’s instruments usually handle the most common parameters such as voltage, current, power, harmonics, voltage dips, flicker and transients. Often it is difficult to say in advanceContinue reading “Choosing The Right Equipment”

Example of Frequency Variations causing SlowScan Recording

Published by Jonny Carlsson, Unipower AB, Case Study: Example of Frequency Variations causing SlowScan Recording, Date: October 25th, 2011. http://www.unipower.se In the following examples a Unipower UP2210 Power Quality meter is measuring SlowScan events. The SlowScan trig level is set to 50Hz +- 0.15Hz with a recorder time of 120 seconds. Example 1:The voltage level isContinue reading “Example of Frequency Variations causing SlowScan Recording”

Harmonic Information Management System

Published by 1. Johan ADOLFSSON, Director, Unipower AB, ja@unipower.se, 2. Peter ANDERSSON, CEO, Unipower AB, psa@unipower.se, 3. Nilesh CHINTALWAR, GM, PCI Ltd, nilesh@prime-pci.in, 4. Shital SHAH, PCI Ltd, shitalshah@prime-pci.in INTRODUCTION In the vast majority of countries today there are regulations and standards implemented that specify the maximum level of harmonic content. Some countries implement theContinue reading “Harmonic Information Management System”