A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks

Published by Jalal Ibrahimov1, Tural Aliyev2, Ilkin Marufov3, Nijat Mammadov4, Azerbaijan State Oil and Industry University ORCID: 3. 0000-0002-3143-0113; 4. 0000-0001-6555-3632 Abstract. The widespread use of electric automobiles will lead to significant changes in instantaneous consumption values and the mechanisms that govern this consumption. Electricity demand will increase sharply and there will be fluctuations inContinue reading “A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks”

Some Issues of Increasing the Efficiency of Electric Machines

Published by Samira KHANAHMEDOVA, Azerbaijan State Oil and Industry UniversityORCID: 0000-0001-8862-1570 Abstract. The article discusses ways to reduce losses to increase efficiency in electric machines. The amount of energy loss is determined by the efficiency coefficient. The issues of changing the size of an electric machine under electromagnetic loads with a constant power source andContinue reading “Some Issues of Increasing the Efficiency of Electric Machines”

Research of Some Problems of Electrical Safety

Published by Elshad Safiyev1, Saida Kerimova2, Kubra Mukhtarova3, Azerbaijan State Oil and Industry University ORCID: 1. 0009-0005-4971-1721 Abstract. The article describes in detail the causes of electric danger, the types of its effects on the human body, and ways to protect against the danger. Schemes of connecting people to single-phase and two-phase current circuits andContinue reading “Research of Some Problems of Electrical Safety”

Residual Current Devices in Electric Vehicles Charging Installations

Published by Stanislaw CZAPP, Gdańsk University of Technology, ORCID: 0000-0002-1341-8276 Abstract. The main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment forContinue reading “Residual Current Devices in Electric Vehicles Charging Installations”

Manage Your Energy Expenses

Published by Dranetz Technologies, Inc., Case Study Utility energy and demand costs have a direct impact on a company’s bottom line. In fact, a typical commercial or industrial facility can save from 10% to as much as 35% annually on energy costs by implementing a comprehensive energy management plan. And while each facility will require an organizedContinue reading “Manage Your Energy Expenses”

Fiber Optic Technology for Pressure Measurements in High Voltage Switchgear

Published by 1. Damian KOSTYŁA1, 2. Paweł WĘGIEREK1, 3. Michał LECH1,Lublin University of Technology, Faculty of Electrical Engineering and Computer Science (1)ORCID: 1. 0000-0002-9012-0158; 2. 0000-0002-0812-3414; 3. 0000-0002-4732-2459 Abstract. The paper presents a review of traditional and fiber optic methods dedicated to pressure measurement in the context of ongoing research work on the development ofContinue reading “Fiber Optic Technology for Pressure Measurements in High Voltage Switchgear”

Power Consumption Control and Monitor using IoT Platform for Smart Office

Published by 1. Sahapong SOMWONG1, 2. Kritsada PUANGSUWAN2,Faculty of Engineering, Rajamangala University of Technology Srivijaya Songkhla, Thailand (1),Faculty of Science and Industrial Technology, Prince of Songkla University, Surat Thani Campus, Surat Thani, Thailand (2) ORCID: (1) 0000-0002-2693-494X; (2) 0000-0003-1613-0611 Abstract. This paper reports the study to design and develop a system for controlling and displayingContinue reading “Power Consumption Control and Monitor using IoT Platform for Smart Office”

Differences between IEC and IEEE Standards of Transformers

Published by Indi. Wang Focus on the transformers | Electrical transformer business developer | With IEC authentication CE ISO9001:2000 Hefei, Anhui, China When it comes to adding or replacing transformers in oil and gas plants, operators need to consider various factors to optimize their operations. In this article, we will explore the differences between theContinue reading “Differences between IEC and IEEE Standards of Transformers”

Extra High Voltage Transmission Line Lightening Protection using Surge Arrester

Published by Ali HAMOODI, Rasha MOHAMMED, Bashar SALIH, Northern Technical University, Engineering technical college Abstract. The objective of this work was to protect the transmission line (T.L.) from the lightning effect. In the last decades, several methodologies have been employed for the rise of lightning performance on the T.L Lightning with high values of currentContinue reading “Extra High Voltage Transmission Line Lightening Protection using Surge Arrester”

Tool to Identify Parameters of Insulation System in Electrical Machines

Published by 1. Barbara KULESZ1, 2. Andrzej SIKORA2, 3. Damian SŁOTA3, Politechnika Śląska, Katedra Elektrotechniki i Informatyki(1,2), Politechnika Śląska, Katedra Zastosowań Matematyki i Metod Sztucznej Inteligencji (3) ORCID: 1. 0000-0002-3602-6013; 2. 0000-0003-3498-5621 3. 0000-0002-9265-5711 Abstract. The issue of the equivalent scheme parameter identification for the insulation system in an electrical machine is discussed in theContinue reading “Tool to Identify Parameters of Insulation System in Electrical Machines”