Published by Tengku Juhana TENGKU HASHIM1, Azah MOHAMED2, Hussain SHAREEF3, Universiti Kebangsaan Malaysia Abstract. Power distribution systems are in the state of transition from passive to active networks due to the rising penetration level of distributed generators (DGs). One of the technical challenges of active networks is to maintain an acceptable voltage level. This problemContinue reading “A Review on Voltage Control Methods for Active Distribution Networks”
Author Archives: PQBlog
General Reference – Effects of Harmonics at Industrial Facilities
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Effects of Harmonics at Industrial Facilities, Document ID: PQS0409, Date: September 30, 2004. Abstract: Harmonic currents injected into the system by nonlinear loads, and the voltage distortion they create as they flow through system impedances, can reduce equipment operating reliability and service life. Potential problemsContinue reading “General Reference – Effects of Harmonics at Industrial Facilities”
Experimental Solar-Based Charging Station for Electric Vehicles
Published by Désiré D. RASOLOMAMPIONONA2, François MAEGHT1, Pierre-Yves CRESSON1,Patrick FAVIER1, I.U.T. de Béthune, Université d’Artois (1), Institute of Electric Power Engineering, Warsaw University of Technology (2) Abstract. For a few years the need of research completion on renewable energy allows the installation of several student projects at the University. A group of co-operating foreign studentsContinue reading “Experimental Solar-Based Charging Station for Electric Vehicles”
Impact of Renewables on Relay Protection Operation
Published by Mikhail ANDREEV, Aleksey SUVOROV, Alisher ASKAROV, Anton KIEVETS, Vladimir RUDNIK, Tomsk Polytechnic University, Russia Abstract. The current trend in the development of electric power systems is the integration of renewable energy sources in the form of distributed generation. It was revealed that one of the main reasons inhibiting this process is a changeContinue reading “Impact of Renewables on Relay Protection Operation”
How High Voltage PTs (VTs) and CTs Limit the Input to PQ Voltage Transient Measuring Instruments and Limit the High Order Harmonic Accuracies of Voltage and Current
Published by Terry Chandler, Director of Engineering, Power Quality Thailand Ltd. & Power Quality Inc., USA. Application Note, Sept. 2013Emails: terryc@powerquality.org, terryc@powerquality.co.th Typical PTs and CTs cause errors and issues in PQ measurements in three areas: 1. Harmonics As the PT and CT have very poor frequency response, they are in affect are a low pass filter onContinue reading “How High Voltage PTs (VTs) and CTs Limit the Input to PQ Voltage Transient Measuring Instruments and Limit the High Order Harmonic Accuracies of Voltage and Current”
Some Aspects of the Growing Penetration of Wind Energy in the Polish Power System
Published by Tadeusz SKOCZKOWSKI1, Maksymilian KOCHAŃSKI1,2, Warsaw University of Technology (1), Research and Innovation Centre Pro-Akademia (2) Abstract. According to the Energy Policy of Poland by 2030 the national power system will have to acquire 12 times more electricity from wind energy than in 2011. This challenging policy goal entails a number of significant consequences.Continue reading “Some Aspects of the Growing Penetration of Wind Energy in the Polish Power System”
General Reference – Modeling for Harmonic Analysis
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Modeling for Harmonic Analysis, Document ID: PQS0303, Date: January 10, 2003. Abstract: Harmonics have existed on electric power systems for many years. Recently, however, much more attention has been given to monitoring and analyzing the presence and effects of harmonics on utility and customer devicesContinue reading “General Reference – Modeling for Harmonic Analysis”
Detecting Power Systems Failure based on Fuzzy Rule in Power Grid
Published by Suren DRAN. R1, Parvatha VARTHINI. B2, Research Scholar, Department of Information Technology, Sathyabama University, Chennai, Tamilnadu, India (1), Professor & Head, Department of Computer Applications, St. Joseph’s College of Engineering, Chennai, Tamilnadu, India (2) Abstract. Load balancing is an important feature that keeps the power system safe from overloading. Load details can beContinue reading “Detecting Power Systems Failure based on Fuzzy Rule in Power Grid”
Experiment and Analysis of High Power Line-Start PM Motor
Published by Qinfen LU, Xiaoyan HUANG, Yunyue YE, Youtong FANG, Zhejiang University Abstract. This paper investigates the performance of a high power line-start permanent-magnet motor (LSPM) by experiment, which is developed for industrial fans, pumps and compressors to reduce the energy consumption. The no-load back-EMF is measured and compared with predicted result of FEM. InContinue reading “Experiment and Analysis of High Power Line-Start PM Motor”
Harmonic Evaluation at an Industrial Facility
Published by Electrotek Concepts, Inc., PQSoft Case Study: Harmonic Evaluation at an Industrial Facility, Document ID: PQS0502, Date: March 31, 2005. Abstract: A harmonic evaluation was performed at the plastic film manufacturer’s facility. The goals of the evaluation were to develop a solution to mitigate the harmonic voltage distortion caused by the ac and dc adjustableContinue reading “Harmonic Evaluation at an Industrial Facility”