Demand Response

Published by Dranetz Technologies, Inc., Case Study Data Center uses Encore to monitor Demand Response Performance A 1.2M square ft Data Center located in Northern New Jersey was participating in a Demand Response program utilizing their backup generators as the primary means of reducing their 7MW of load. The service provider that they worked with installed telemetryContinue reading “Demand Response”

Overloaded Service

Published by Dranetz Technologies, Inc., Case Study A busy trading floor was experiencing difficulties with their six air handling units, which were fed from a single 480V, 400-amp service. The units were malfunctioning, stalling and at times were unable to start, causing the temperature in the control room to rise to unacceptable levels. A Dranetz Power PlatformContinue reading “Overloaded Service”

400Hz Monitoring – Aviation Applications

Published by Dranetz Technologies, Inc., Application Note INTRODUCTION Most of the world distributes power at 50Hz or 60Hz. However, there are certain specialized applications that distribute power at other frequencies. Applications such as aviation, naval, and others distribute power at 400Hz to improve system efficiencies. 400Hz applications can be a challenge for the end user since mostContinue reading “400Hz Monitoring – Aviation Applications”

2 Week Energy Survey

Published by Dranetz Technologies, Inc., Case Study Willows Swim Club is a private, member-owned swimming and recreational facility located in central New Jersey. The swim club provides kitchen space to a local restaurant to operate a food concession. Being offered as a service to its membership, there is presently no charge for rent or utilities. However, givenContinue reading “2 Week Energy Survey”

Comparison of Compact Fluorescent to Incandescent Bulbs

Published by Dranetz Technologies, Inc., Case Study With the proliferation of Compact Florescent (CF) lighting, we thought it would be interesting to do a side by side comparison to an incandescent bulb using our new Energy Platform EP1. Not only is it a great demonstration of the capabilities of the EP1 but it’s also an opportunity toContinue reading “Comparison of Compact Fluorescent to Incandescent Bulbs”

Glass Factory Failure of Electronic Controls

Published by Dranetz Technologies, Inc., Case Study The customer was experiencing repeated failures electronic controls and instruments in a new glass factory. The factory had been imported from a 60hz country to a 50hz country. In this case, the new factory capacity was reduced by 50% or more do the frequent shut downs and stoppages. The costContinue reading “Glass Factory Failure of Electronic Controls”

The Critical Role of Power Quality Evaluation in Solar Installations

Published by Dranetz Technologies, Inc., Application Note EXECUTIVE SUMMARY As solar photovoltaic (PV) systems become more prevalent in commercial and industrial environments, the emphasis on financial return and concise performance expectations has rightly intensified. However, one often-overlooked aspect of solar deployment is the comprehensive evaluation of power quality (PQ)—both before and after installation. By identifying existing gridContinue reading “The Critical Role of Power Quality Evaluation in Solar Installations”

Localizing Faults in Power Transmission Line with Applying Signals of Directional Elements at Both Line Ends

Published by 1. Justyna HERLENDER, 2. Jan IŻYKOWSKI, Wroclaw University of Science and Technology, Faculty of Electrical Engineering, Department of Electrical Power Engineering Professor emeritus. ORCID 1. 0000-0002-9469-4546; 2. 0000-0002-1048-551 Abstract. This paper presents the algorithm intended for localizing faults in a power transmission line for an inspection-repair purpose. Its innovative element is that aContinue reading “Localizing Faults in Power Transmission Line with Applying Signals of Directional Elements at Both Line Ends”

Selected Voltage Control Methods in LV Local Distribution Grids with High Penetration of PV

Published by Paweł SZCZEŚNIAK1, Piotr POWROŹNIK2, Elżbieta SZTAJMEC3, University of Zielona Góra, Institute of Automatic Control, Electronics and Electrical Engineering (1), University of Zielona Góra, Institute of Metrology, Electronics and Computer Science (2), Rzeszow University of Technology, Departament of Power Electronics and Power Engineering (3)ORCID: 1.0000-0002-5822-3878; 2.0000-0001-7485-9959; 3.0000-0002-2125-0207 Abstract. The growth in new prosumer electricityContinue reading “Selected Voltage Control Methods in LV Local Distribution Grids with High Penetration of PV”

A Novel Method to Improve the Power Quality Via Hybrid System

Published by 1. Raghad Adeeb Othman1, 2. Omar Sh. Alyozbaky2,Department of Electrical Engineering, College of Engineering, University of Mosul, Iraq (1,2)ORCID: 1. 0000-0001-5875-9210; 2. 0000-0002-9735-1469 Abstract. Ever increasing electricity demand as well as the rapid depletion of fossil fuels have increased the need for hybrid power systems that integrate distributed energy resource (DER) systems; suchContinue reading “A Novel Method to Improve the Power Quality Via Hybrid System”