Published by M.Sc Marko Pikkarainen, M.Sc Pekka Nevalainen, Dr. Pertti Pakonen, Prof. Pekka Verho, Tampere University of Technology, marko.pikkarainen@tut.fi ABSTRACT Two matters have strongly affected use of energy in Finland during recent years. The one is the greenhouse effect and the other is the energy price which has risen. These points have brought to theContinue reading “Practical Case Study: Measurement of Power Quality Problems Caused by Common New Loads”
Tag Archives: Power Quality
General Reference – Using Simulations and Measurements in PQ Analysis
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Using Simulations and Measurements in PQ Analysis, Document ID: PQS0309, Date: April 16, 2003. Abstract: Simulations provide a convenient means to characterize power quality problems, predict disturbance characteristics, and evaluate possible solutions to problems. They should be performed in conjunction with monitoring efforts and measurementsContinue reading “General Reference – Using Simulations and Measurements in PQ Analysis”
Program on Technology Innovation: A History of Power Quality
Addressing Evolving Customer Technologies and an Increasingly Complex Power Grid Published by Electric Power Research Institute (EPRI), Inc. Document ID: 3002022396, March 2022. Introduction Over the past 50 years, the concept of power quality (PQ) has evolved from being an unknown and undefined concept to being understood as a fundamental component of grid performance, utilityContinue reading “Program on Technology Innovation: A History of Power Quality”
General Reference – Approach to Systems Monitoring
Published by Electrotek Concepts, Inc., PQSoft Case Study: General Reference – Approach to Systems Monitoring, Document ID: PQS0310, Date: April 16, 2003. Abstract: Power quality monitoring is an essential service many utilities perform for their industrial and other key commercial customers. Because of the technology and software now available, this monitoring is highly effective. Not onlyContinue reading “General Reference – Approach to Systems Monitoring”
Monitoring and Analysis of Power Quality Issues in Distribution Network
– A Case Study Published by V. S. Jape#1, D. S. Bankar*2, Tejaswini Sarwade#3Electrical Engineering1, Electrical Engineering2, Electrical Engineering3, BVDU Pune1, BVDU Pune2, SPPU Pune31jape_swati@yahoo.co.in , 2dsbankar@bvucoep.edu.in , 3sarwadet@gmail.com Abstract — Tracking of system overall performance in phrases of Power Quality disturbances and its ill effects on distribution network is growing attention of application towardsContinue reading “Monitoring and Analysis of Power Quality Issues in Distribution Network”
Industrial Power Quality Problems
Published by A. El Mofty K. Youssef, Alexandria Electricity Company , Alexandria – Egypt SUMMARY Power quality has become an increasing concern to Alexandria Electricity Company (AEC) for the last few years. Problems involving the quality of voltage to the customers are always an important point. The increased concern of power quality has resulted inContinue reading “Industrial Power Quality Problems”
Analysis of Power Quality Factors: A Case Study of Windhoek, Namibia
Published by Aldrin Mubiana, Michael Mutingi, Member, IAENG, Gideon Gope, Charles Mbohwa. Conference: Proceedings of the World Congress on Engineering and Computer Science 2016 Vol II WCECS 2016, October 19-21, 2016, San Francisco, USA. Abstract—Power quality (PQ) is concerned with control of harmonic distortions, voltage variations, voltage reductions, power interruptions and voltage surges. Enterprises devicesContinue reading “Analysis of Power Quality Factors: A Case Study of Windhoek, Namibia”
Wind Turbine Operation in Power Systems & Grid Connection Requirements
Published by K. B. Mohd. Umar Ansari1, Manjeet Singh2, Sandeep Kumar3 B.E (EEE), M.Tech (Electrical Power & Energy Systems), Ex- Engineer – GET, Tata Motors Pvt. Ltd., Sector 11,Udham Singh Nagar, Pantnagar, UK, India. 1B.Tech (EN), Ex-Electrical Engineer, Flowmore Limited, Sahibabad, Ghaziabad, U.P., India2B.Tech (EE), M.Tech (Power Systems*), Lecturer, Department of Electrical Engg, Sri RamSwaroopContinue reading “Wind Turbine Operation in Power Systems & Grid Connection Requirements”
Power Quality Issues in Smart Grid Environment – Serbian Case Studies
Published by ALEKSANDAR JANJIĆ, Department of renewable energy sources, R&D Center “Alfatec” Ltd. Bul. Nikole Tesle 63/5,18000 Niš, SERBIA, aleksandar.janjic@alfatec.rs ZORAN P. STAJIĆ, Faculty of Electronic Engineering, University of Niš, Aleksandra Medvedeva 14, 18000 Niš, SERBIA, zoran.stajic@alfatec.rs IVAN RADOVIĆ, ED “Elektrošumadija” Kragujevac, ED “Centar” d.o.o. Kragujevac, Slobode 7, 34000 Kragujevac, SERBIA, ivan.radovic@eskg.rs Abstract: – TheContinue reading “Power Quality Issues in Smart Grid Environment – Serbian Case Studies”
Power Quality Problems
Published by CEA Technologies Inc. (CEATI), POWER QUALITY Energy Efficiency Reference Guide, Chapter 3 – Power Quality Problems. 3.1 How Power Quality Problems Develop Three elements are needed to produce a problematic power line disturbance: A source A coupling channel A receptor If a receptor that is adversely affected by a power line deviation isContinue reading “Power Quality Problems”