Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load

Published by Mustafa Hussein Ibrahim1, Muhammed A Ibrahim2, Salam Ibrahim khather3, University of Mosul (1), Ninevah University (2,3) ORCID: 1. 0000-0002-9950-6524, 2. 0000-0003-4818-1245, 3. 0000-0002-9082-2360 Abstract. The standalone solar photovoltaic system (SA-SPV) is an appealing alternative for carrying out the electrification process in rural regions through packages in lots of countries. The photovoltaic systems areContinue reading “Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load”

Example of Frequency Variations causing SlowScan Recording

Published by Jonny Carlsson, Unipower AB, Case Study: Example of Frequency Variations causing SlowScan Recording, Date: October 25th, 2011. http://www.unipower.se In the following examples a Unipower UP2210 Power Quality meter is measuring SlowScan events. The SlowScan trig level is set to 50Hz +- 0.15Hz with a recorder time of 120 seconds. Example 1:The voltage level isContinue reading “Example of Frequency Variations causing SlowScan Recording”

Container Harbour in Gothenburg

Published by Jonny Carlsson, Unipower AB, Case Study: Container Harbour in Gothenburg, Date: November 8th, 2010. http://www.unipower.se The most important problem was the sags that were caused by the container cranes. The cranes created a lot of high reactive power during the start of the lift procedure. The high currents caused high demand on the transformerContinue reading “Container Harbour in Gothenburg”

Transient Detection using Peak Detectors

Published by Jonny Carlsson, Unipower AB, http://www.unipower.se Background The main problem with transients in the electrical network is that a high voltage potential might break the isolation barrier in for example cables or other equipment in the electrical network. It may also harm semiconductors that are sensitive of high voltage. A transient voltage is byContinue reading “Transient Detection using Peak Detectors”

Dynamic Voltage Restorer for Voltage Unbalance Mitigation and Voltage Profile Improvement in Distribution Network

Publishd by Ahmed A. Abdullah AL-KARAKCHI1, Enaam ALBANNA2, Alya H. AL-RIFAIE3, Northern Technical University (1,2,3) ORCID: 1. 0000-0003-1151-3015; 2. 0000-0002-3974-0116; 3. 0000-0002-7978-2193 Abstract. Unbalanced network voltage damages utility and end-user equipment. Electrified trains, single-phase distributed generators, and line-toline connected industrial loads can increase voltage imbalances. Using Dynamic Voltage Restorer (DVR) at appropriate places is oneContinue reading “Dynamic Voltage Restorer for Voltage Unbalance Mitigation and Voltage Profile Improvement in Distribution Network”

Extra High Voltage Transmission Line Lightening Protection using Surge Arrester

Published by Ali HAMOODI, Rasha MOHAMMED, Bashar SALIH, Northern Technical University, Engineering technical college Abstract. The objective of this work was to protect the transmission line (T.L.) from the lightning effect. In the last decades, several methodologies have been employed for the rise of lightning performance on the T.L Lightning with high values of currentContinue reading “Extra High Voltage Transmission Line Lightening Protection using Surge Arrester”

Power Quality Improvement in Distributed Generation System under varying Load Conditions using PWM and Hysteresis Controller

Published Vijayshree G1, Sumathi S2, RNSIT, Bangalore,Karnataka,India(1). RNSIT, Bangalore,Karnataka, India(2) Abstract – This paper proposes a power system network modeled using a microgrid, integrated with wind and solar photovoltaic (PV) resources, along with the battery energy storage system (BESS) connected to the three-phase grid feeding the linear and nonlinear load. The simulation is carried outContinue reading “Power Quality Improvement in Distributed Generation System under varying Load Conditions using PWM and Hysteresis Controller”

Evaluating Direction of Harmonics – Power Harmonics

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se One important issue is how to trace the source of harmonics. The example below shows harmonic filters connected until 11.00 and there is no voltage distortion as expected. After 11.00 the filters were disconnected due to a fault and voltage harmonics can be seen.Continue reading “Evaluating Direction of Harmonics – Power Harmonics”

Application of the Permanent Magnet Synchronous Motors for Tower Cranes

Published by Łukasz KNYPIŃSKI1,2, Jacek KRUPIŃSKI2, Poznan University of Technology(1), Krupinski Cranes Sp. z o.o.(2) Abstract. The paper presents the results of experimental research concerning the application of the permanent magnet synchronous motors for tower cranes. The modern permanent magnet synchronous motors (PMSM) are characterized by better operating parameters in relation to squirrel cage inductionContinue reading “Application of the Permanent Magnet Synchronous Motors for Tower Cranes”

Eccentricity Fault Identification in Round Rotor Synchronous Motors considering Load Variation

Published by Bashir Mahdi EBRAHIMI1, Jawad FAIZ1, Mohammad ETEMADREZAIE2, Mojtaba BABAIE3, Center of Excellence on Applied Electromagnetic Systems, School of Electrical and Computer Engineering, University of Tehran, Tehran, Iran(1), Department of electrical and computer engineering, Delft, Zuid-holland, Netherlands(2), Faculty of Engineering, Science and Research Campus, Islamic Azad University, Tehran, Iran(3) Abstract. Impacts of load variationContinue reading “Eccentricity Fault Identification in Round Rotor Synchronous Motors considering Load Variation”