Improving the Operation Characteristics of Non-Insulated Overhead Power Lines

Published by 1. Oleksandr KOZLOVSKYI1, 2. Dmitro TRUSHAKOV1, 3. Oleksandr SAVCHENKO2, 4. Serhiy RENDZINYAK3, 5. Vasyl KORUD3, Central Ukrainian National Technical University (1), Kharkiv Petro Vasylenko National Technical University of Agriculture (2), Lviv Polytechnic National University (3)ORCID: 1.0000-0001-6885-5994; 2.0000-0003-0326-2383, 3.0000-0002-6401-0852, 4.0000-0003-4544-4871, 5.0000-0002-1289-3534 Abstract. Methods of protection of wires of overhead power lines of group “anti-icing”Continue reading “Improving the Operation Characteristics of Non-Insulated Overhead Power Lines”

A Statistical Analysis of Wind Speed Probabilistic Distributions for the Wind Power Assessment in Different Regions

Published by 1. Yuly Bay, 2. Nikolay Ruban, 3. Mikhail Andreev, 4. Alexandr Gusev, Tomsk Polytechnic University. ORCID. 1. 0000-0001-9928-408X, 2. 0000-0003-1396-9104, 3. 0000-0002-6420-4374, 4. 0000-0003-0814-2356 Abstract. The penetration of renewable energy sources (RES) into the electricity supply is gaining popularity all over the world, including countries that have large oil and gas reserves, sinceContinue reading “A Statistical Analysis of Wind Speed Probabilistic Distributions for the Wind Power Assessment in Different Regions”

Simplified Formula for the Load Losses of Active Power in Power Lines taking into Account Temperature

Published by Stanislav S. GIRSHIN, Oleg V. KROPOTIN, Vladislav M. TROTSENKO, Aleksandr O. SHEPELEV, Elena V. PETROVA, Vladimir N. GORYUNOV, Omsk State Technical University, Omsk, Russia Abstract. The use of a simplified formula for calculation of active power losses in transmission lines taking into account the temperature in the stationary thermal regime is considered. TheContinue reading “Simplified Formula for the Load Losses of Active Power in Power Lines taking into Account Temperature”

Power Flow and Stability Analyses of a UPQC System Integrated into a Distribution Network

Published by Rachid Dehini1, Ryma Berbaoui, Othmane Abdelkhalek, Electrical engineering Department, University of Tahri Mohamed. B.P 417 BECHAR (08000), Algeria. ORCID: 1 https://orcid.org/0000-0002-8769-218X Abstract. This paper deals with the active and reactive power flow analysis inside the unified power quality conditioner (UPQC) during several cases. The UPQC is a combination of shunt and series activeContinue reading “Power Flow and Stability Analyses of a UPQC System Integrated into a Distribution Network”

Intelligent Fault Location Algorithms for Distributed Generation Distribution Networks: A Review

Published by 1. Diego GIRAL-RAMÍREZ1, 2. Cesar HERNÁNDEZ-SUAREZ1, 3. José CORTES-TORRES2,Universidad Distrital Francisco José de Caldas, Bogotá, Colombia (1)Universidad Industrial de Santander, Bucaramanga, Colombia (2)ORCID: 1. 0000-0001-9983-4555, 2. 0000-0002-7974-5560, 3. 0000-0001-9232-6785 Abstract. Distributed Generation (DG) is a small-scale technology linked to consumers through the distribution system and has a high potential for technical, economic, andContinue reading “Intelligent Fault Location Algorithms for Distributed Generation Distribution Networks: A Review”

Overview of Control System Topology of Flywheel Energy Storage System in Renewable Energy Application for Alternative Power Plant

Published by M.S. ALI1,2, Mahidur R SARKER3, Mohamad Hanif Md SAAD3, Ramizi MOHAMED1, 1Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia; 2Electrical Engineering Department, German-Malaysian Institute , Jalan Ilmiah, Taman Universiti,43000, Kajang, Selangor, Malaysia; 3Institute of IR 4.0, Universiti Kebangsaan Malaysia, 43600 UKM Bangi,Continue reading “Overview of Control System Topology of Flywheel Energy Storage System in Renewable Energy Application for Alternative Power Plant”

Analysis of Transient Electromagnetic Processes in the Ultrahigh Voltage Transmission Line during Two-Phase Short Circuits

Published by 1. Tomasz PERZYŃSKI1, 2. Vitaliy LEVONIUK2, 3. Radosław FIGURA1, Faculty of Transport, Electrical Engineering and Computer Science, University of Technology and Humanities in Radom (1) Department of Electrical Systems, Lviv National Agrarian University (2)ORCID: 1. 0000-0001-5105-5034; 2. 0000-0003-2113-107X; 3. 0000-0001-8048-5623 Abstract. The mathematical model of a fragment of ultrahigh voltage electric network isContinue reading “Analysis of Transient Electromagnetic Processes in the Ultrahigh Voltage Transmission Line during Two-Phase Short Circuits”

An Analysis of Remote Voltage Measurement in the Medium Voltage Cable Networks

Published by 1. Jacek KOZYRA1, 2. Zbigniew ŁUKASIK1, 3. Aldona KUŚMIŃSKA-FIJAŁKOWSKA1, 4. Paweł KASZUBA2, Kazimierz Pulaski University of Technology and Humanities in Radom, (1), Volta Instalacje (2) ORCID: 1. 0000-0002-6660-6713, 2. 0000-0002-7403-8760, 3. 0000-0002-9466-1031, 4. 0000-0003-1120-5901 Abstract. Due to changes occurring both in industrial area and in private consumers, availability of modern electric and electronicContinue reading “An Analysis of Remote Voltage Measurement in the Medium Voltage Cable Networks”

An Analysis of Power Quality Problems and its Mitigation

Published by Shafqat Mughal, Neeten Sharma, Pankhuri Kishore Abstract—Power Quality is a major concern of our modern industries and other consumers. Poor quality of supply will affect the performance of customer equipment such as computers, microprocessors adjustable speed drives, power electronic devices, life saving equipment in hospitals, etc. and result in heavy financial losses toContinue reading “An Analysis of Power Quality Problems and its Mitigation”

Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation

Published by Hana’ A. Rabab’ah 1, Yaser N. Anagreh2, Al-Ahliyya Amman University (1), Yarmouk University (2) ORCID: 1. 0000-0002-1581-7721; 2. 0000-0002-3826-9262 Abstract. This paper presents an integrated stand-alone wind / Photovoltaic (PV) system enhanced with storage system and the required controllers. The proposed scheme concerned with maximum electrical power extracting from the two renewable energyContinue reading “Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation”