Choosing The Right Equipment

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se What do you need to measure? Power quality is assessed based on a number of power quality parameters. Today’s instruments usually handle the most common parameters such as voltage, current, power, harmonics, voltage dips, flicker and transients. Often it is difficult to say in advanceContinue reading “Choosing The Right Equipment”

Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load

Published by Mustafa Hussein Ibrahim1, Muhammed A Ibrahim2, Salam Ibrahim khather3, University of Mosul (1), Ninevah University (2,3) ORCID: 1. 0000-0002-9950-6524, 2. 0000-0003-4818-1245, 3. 0000-0002-9082-2360 Abstract. The standalone solar photovoltaic system (SA-SPV) is an appealing alternative for carrying out the electrification process in rural regions through packages in lots of countries. The photovoltaic systems areContinue reading “Modelling and Analysis of SA-SPV System with Bi-Directional Inverter for Lighting Load”

Example of Frequency Variations causing SlowScan Recording

Published by Jonny Carlsson, Unipower AB, Case Study: Example of Frequency Variations causing SlowScan Recording, Date: October 25th, 2011. http://www.unipower.se In the following examples a Unipower UP2210 Power Quality meter is measuring SlowScan events. The SlowScan trig level is set to 50Hz +- 0.15Hz with a recorder time of 120 seconds. Example 1:The voltage level isContinue reading “Example of Frequency Variations causing SlowScan Recording”

Container Harbour in Gothenburg

Published by Jonny Carlsson, Unipower AB, Case Study: Container Harbour in Gothenburg, Date: November 8th, 2010. http://www.unipower.se The most important problem was the sags that were caused by the container cranes. The cranes created a lot of high reactive power during the start of the lift procedure. The high currents caused high demand on the transformerContinue reading “Container Harbour in Gothenburg”

Differences between IEC and IEEE Standards of Transformers

Published by Indi. Wang Focus on the transformers | Electrical transformer business developer | With IEC authentication CE ISO9001:2000 Hefei, Anhui, China When it comes to adding or replacing transformers in oil and gas plants, operators need to consider various factors to optimize their operations. In this article, we will explore the differences between theContinue reading “Differences between IEC and IEEE Standards of Transformers”

Harmonic Information Management System

Published by 1. Johan ADOLFSSON, Director, Unipower AB, ja@unipower.se, 2. Peter ANDERSSON, CEO, Unipower AB, psa@unipower.se, 3. Nilesh CHINTALWAR, GM, PCI Ltd, nilesh@prime-pci.in, 4. Shital SHAH, PCI Ltd, shitalshah@prime-pci.in INTRODUCTION In the vast majority of countries today there are regulations and standards implemented that specify the maximum level of harmonic content. Some countries implement theContinue reading “Harmonic Information Management System”

ERP Systems in Energy Industry – Opportunities and Challenges

Published by 1. Edyta KUCHARSKA, 2. Katarzyna GROBLER-DĘBSKA, 3. Jerzy BARANOWSKI, 4. Waldemar BAUER, 5. Nataliia KASHPRUK, AGH UNIVERSITY OF SCIENCE AND TECHNOLOGY, KRAKOW, POLAND ORCID: 1. 0000-0001-6551-5062; 2. 0000-0003-3062-5987, 3. 0000-0003-3313-581X, 4. 0000-0002-8543-0995, 5. 0000-0001-5599-5509 Abstract. The article describes the use of ERP systems to support the management of companies in the energy industry.Continue reading “ERP Systems in Energy Industry – Opportunities and Challenges”

Measuring PQ Issues in a Bus Depot Using Unipower HW and Software

Published by Unipower AB, Metallgatan 4C, 44132 Alingsås, Sweden. Email: info@unipower.se Introduction This case study explores how advanced power quality measurement technology facilitated the diagnosis of severe power quality disturbances in a bus depot. These disturbances, which neither the bus operator nor the bus manufacturer initially attributed to electrical quality issues, were ultimately traced toContinue reading “Measuring PQ Issues in a Bus Depot Using Unipower HW and Software”

Transient Detection using Peak Detectors

Published by Jonny Carlsson, Unipower AB, http://www.unipower.se Background The main problem with transients in the electrical network is that a high voltage potential might break the isolation barrier in for example cables or other equipment in the electrical network. It may also harm semiconductors that are sensitive of high voltage. A transient voltage is byContinue reading “Transient Detection using Peak Detectors”

Dynamic Voltage Restorer for Voltage Unbalance Mitigation and Voltage Profile Improvement in Distribution Network

Publishd by Ahmed A. Abdullah AL-KARAKCHI1, Enaam ALBANNA2, Alya H. AL-RIFAIE3, Northern Technical University (1,2,3) ORCID: 1. 0000-0003-1151-3015; 2. 0000-0002-3974-0116; 3. 0000-0002-7978-2193 Abstract. Unbalanced network voltage damages utility and end-user equipment. Electrified trains, single-phase distributed generators, and line-toline connected industrial loads can increase voltage imbalances. Using Dynamic Voltage Restorer (DVR) at appropriate places is oneContinue reading “Dynamic Voltage Restorer for Voltage Unbalance Mitigation and Voltage Profile Improvement in Distribution Network”