Published by Electrotek Concepts, Inc., PQSoft Case Study: Distribution Feeder Wind Turbine Generator Analysis, Document ID: PQS1206, Date: January 26, 2012. Abstract: This case study presents a distribution feeder wind turbine generator analysis. The investigation included several potential causes of turbine and feeder overcurrents and overvoltages, including wind speed variations, cut-out and cut-in switching operations, groundContinue reading “Distribution Feeder Wind Turbine Generator Analysis”
Tag Archives: Wind Turbines
Wind Turbine Operation in Power Systems & Grid Connection Requirements
Published by K. B. Mohd. Umar Ansari1, Manjeet Singh2, Sandeep Kumar3 B.E (EEE), M.Tech (Electrical Power & Energy Systems), Ex- Engineer – GET, Tata Motors Pvt. Ltd., Sector 11,Udham Singh Nagar, Pantnagar, UK, India. 1B.Tech (EN), Ex-Electrical Engineer, Flowmore Limited, Sahibabad, Ghaziabad, U.P., India2B.Tech (EE), M.Tech (Power Systems*), Lecturer, Department of Electrical Engg, Sri RamSwaroopContinue reading “Wind Turbine Operation in Power Systems & Grid Connection Requirements”
Wind Plant Voltage Flicker Data Analysis
Published by Electrotek Concepts, Inc., PQSoft Case Study: Wind Plant Voltage Flicker Data Analysis, Document ID: PQS1202, Date: January 26, 2012. Abstract: This case study presents the results for a wind plant voltage flicker data analysis. The characteristics of voltage flicker are mainly determined by load characteristics and the short-circuit capacity. The wind plant substationContinue reading “Wind Plant Voltage Flicker Data Analysis”
Power Quality Measurements and Analysis for Wind Turbines
Published by Mariano Sanz, Member, IEEE, Andrés Llombart, Member, IEEE, Ángel Antonio Bayod and Joaquín Mur, Student Member, IEEE Abstract— A new system for studying power quality (PQ) in wind turbines (WT) has been designed using a data acquisition board (DAQ), LabVIEW programming software and a portable PC. The system has been installed at windContinue reading “Power Quality Measurements and Analysis for Wind Turbines”
Wind Energy Conversion System from Electrical Perspective — A Survey
Published by Hyong Sik Kim, Dylan Dah-Chuan Lu, School of Electrical and Information Engineering, University of Sydney, Sydney, Australia. Email: hkim4210@uni.sydney.edu.au Smart Grid and Renewable Energy, 2010, 1, 119-131 doi:10.4236/sgre.2010.13017 Published Online November 2010 (http://www.SciRP.org/journal/sgre). Received October 20th, 2010; revised November 14th, 2010; accepted November 20th, 2010. ABSTRACT This paper focuses on the wind energyContinue reading “Wind Energy Conversion System from Electrical Perspective — A Survey”
Power Quality Measurements Near DER and Disturbing Loads
Published by Ir. M. van Lumig, Electrical Power Systems, Analysis and Concepts Laborelec NL Beek-Maastricht Airport, the Netherlands, e-mail: michiel.vanlumig@laborelec.com Ir. S. Bhattacharyya, Electrical Energy Systems Group Technical University Eindhoven Eindhoven, the Netherlands, e-mail: s.bhattacharyya@tue.nl Dr. ir. J.F.G. Cobben, Electrical Energy Systems Group Technical University Eindhoven Eindhoven, the Netherlands Prof.ir. W.L. Kling, Electrical Energy SystemsContinue reading “Power Quality Measurements Near DER and Disturbing Loads”
Power Quality Standards for Utility Wind and Solar Power Plants
Published by David Mueller, E. H. Camm. Abstract Power quality standards exist to guide the interconnection requirements of large wind and solar plants. IEEE guidelines exist for flicker and harmonics, while IEC guidelines exist for the measurement criteria of power quality phenomena and the characterization of wind turbine equipment. There are also some uniform guidelinesContinue reading “Power Quality Standards for Utility Wind and Solar Power Plants”
Placement and Sizing Optimization for DER Based on Single Phase Wind Turbine Generator in Distribution System Using HPSO
Published by Miss Panaya Sudta, Customer Relation Division, Provincial Electricity Authority, Email: nica_pny@hotmail.com Prof. Weerakorn Ongsakul, Energy Field of Study (FoS) of SERD, Asian Institute of Technology, Email: ongsakul@gmail.com Mr.Patiphan Thupphae, Energy Field of Study (FoS) of SERD, Asian Institute of Technology, Email: sunpatiparn@gmail.com Mr. Wichian Khumwong, Customer Relation Division, Provincial Electricity Authority, Email: wichian.k@gmail.comcomContinue reading “Placement and Sizing Optimization for DER Based on Single Phase Wind Turbine Generator in Distribution System Using HPSO”
Power Quality Considerations of Wind Power Plants
Published by David Mueller, P.E., Manager, Power System Studies, Electrotek Concepts, Inc., Knoxville, Tennessee, USA Email: davem@electrotek.com Presented at 2010 Georgia Tech Fault Disturbance Analysis Conference Abstract Wind power plants are the fastest growing power generation source, and this trend is expected to continue. This paper describes the different types of wind power turbine electricalContinue reading “Power Quality Considerations of Wind Power Plants”
A Comprehensive Review of Power Quality Issues & Measurement for Grid-integrated Wind Turbines
Published by Ahmed F. Zobaa and Ibrahim Ahmed, Department of Electronic and Computer Engineering, Brunel University London, Uxbridge, UB8 3PH, UK. Shady H.E. Abdel Aleem, Mathematical and Physical Sciences, 15th of May Higher Institute of Engineering, Cairo, Egypt. Journal Article: Recent Advances in Electrical & Electronic Engineering, 2019, 12, 210-222 (Volume 12, Issue 3 ,2019)Continue reading “A Comprehensive Review of Power Quality Issues & Measurement for Grid-integrated Wind Turbines”