Published by Raghawendra Sharan Mishra, Student, Department of Instrumentation & Control, Maharana Pratap College of Technology, Gwalior, India. Mr. Prasant Kumar, Assistant Professor, Department of Electrical Engineering, Maharana Pratap College of Technology, Gwalior, India. IJSRD – International Journal for Scientific Research & Development | Vol. 5, Issue 09, 2017 | ISSN (online): 2321-0613 Abstract PowerContinue reading “Survey on Voltage Improvement”
Tag Archives: Transients
Effects of Voltage Sags, Swell and other Disturbances on Electrical Equipment and their Economic Implications
Published by Norbert EDOMAH, Industrial Co-ordinator, Institute for Industrial Technology (IIT), Lagos, Nigeria. E-mail: ncedomah@yahoo.co.uk Published in CIRED 20th International Conference on Electricity Distribution, Prague, 8 -11 June 2009. ABSTRACT Poor power quality has come to stay in most parts of the world. In most part of Africa, especially in Nigeria, it is almost normalContinue reading “Effects of Voltage Sags, Swell and other Disturbances on Electrical Equipment and their Economic Implications”
Summary of U.S. Distribution System Power Quality Levels
Published by D. D. Sabin, Email: dsabin@electrotek.com D. L. Brooks, Email: dbrooks@electrotek.com Electrotek Concepts, Inc., 409 North Cedar Bluff Road, Suite 500, Knoxville, Tennessee 37923-3605, United States A. Sundaram, Email: asundara@epri.com S. Bhatt, Email: sbhatt@epri.com Electric Power Research Institute, 3412 Hillview Avenue, Palo Alto, California 94304-1395, United States Abstract The Distribution System Power Quality ProjectContinue reading “Summary of U.S. Distribution System Power Quality Levels”
Learn What is the Purpose of Lightning Arrester and Why is Testing Necessary
Published by Carelabs (Carelabz) A Lightning Arrester, Surge arrester or Line arrester is a device used on electrical power systems and telecommunications systems to protect the insulation and conductors of the system from the damaging effects of lightning. The typical Lightning Arrester has a high-voltage terminal and a ground terminal. When a lightning surge (or switching surge) travelsContinue reading “Learn What is the Purpose of Lightning Arrester and Why is Testing Necessary”
PowerCET®: The Electric Utility System
Published by PowerCET® Corporation, Course: PQ103, 2007. Introduction to Power Quality: Problems, Analysis & Solutions – The Electric Utility System.
PQ Symptoms in the Medical Industry
Published by Terry Chandler, Director of Engineering, Power Quality Thailand LTD/Power Quality Inc., USA. Emails: terryc@powerquality.org, terryc@powerquality.co.th
Harmonics Mitigation and Power Quality Improvement in Grid Connected Wind Power Plant Using STATCOM
Published by Nasiru B. Kadandani, Department of Electrical Engineering, Bayero University, Kano, Nigeria. Email: nbkadandani.ele@buk.edu.ng. Published in: The Proceedings of Second International Conference on Electrical and Electronics Engineering, Clean Energy and Green Computing, Konya, Turkey, 2015. Abstract Grid integration of intermittent renewable energy sources like wind and solar is usually associated with power quality disturbanceContinue reading “Harmonics Mitigation and Power Quality Improvement in Grid Connected Wind Power Plant Using STATCOM”
PQ Analysis: Flicker, Transients and Noise
Published by testguy, November 23, 2019. Website: testguy.net Flicker, Transients and Noise Repetitive voltage reductions in lighting circuits can be detected by the human eye, a phenomena known as “flicker.” The term flicker refers to a very specific problem related to human perception of light produced by incandescent light bulbs, not necessarily general voltage fluctuations. Some commonContinue reading “PQ Analysis: Flicker, Transients and Noise”
Fluke 43B PQ Analyzer – Receptacle Branch Circuits
Applications Guide, April 2001 Published by Fluke Corporation Troubleshooting Electrical Distribution Systems The most efficient way to troubleshoot electrical systems, is to begin at the load and work towards the building’s service entrance. Measurements are taken along the way to isolate faulty components or loads. This chapter describes typical measurements for troubleshooting problems on receptacleContinue reading “Fluke 43B PQ Analyzer – Receptacle Branch Circuits”
Bridging the Gap Between Signal and Power
Assessing Power System Quality using Signal Processing Techniques Published by Math H.J. Bollen1, Irene Y.H. Gu2, Surya Santoso3, Mark F. McGranaghan4, Peter A. Crossley5, Moisés V. Ribeiro6, and Paulo F. Ribeiro7 Source: IEEE Signal Magazine, 2009 Signal processing has been used in many different applications, including electric power systems. This is an important category, sinceContinue reading “Bridging the Gap Between Signal and Power”