Published by 1. Róbert Štefko1, 2. Michal Kolcun1, 3. Marek Bobček1, 4. Damian Mazur2 , 5. Bogdan Kwiatkowski2, Technical University of Košice (1), Rzeszow University of Technology (2) ORCID: 1. 0000-0002-2477-4559, 2. 0000-0002-8041-9076, 3. 0009-0004-1912-211X; 4. 0000-0002-3247-5903, 5. 0000-0001-5287-2191 Abstract. The continuous rise in electricity consumption and the integration of renewable energy sources into distributionContinue reading “Design of a Protection System for Distributed Energy Sources in Distribution Grids”
Tag Archives: Smart / Microgrids
A Hybrid Approach for Enhancing Grid Restoration
Published by Minaxi1, Sanju Saini2, Garima Tiwari3, Deenbandhu Chhotu Ram University of Science and Technology, Murthal ORCID: 1. 0000-0003-4172-725X; 2. 0000-0003-1390-4861; 3. 0000-0002-3004-0375 Abstract. Blackout restoration is crucial to energy security and infrastructure resilience. Black-start procedures must be used to restore a power grid methodically. Grid recovery requires selecting the correct unit black-start optimization methods.Continue reading “A Hybrid Approach for Enhancing Grid Restoration”
Analysis of Electrical Generators for Wind Electric Installations
Published by Aliashraf BAKHTIYAROV1, Gulshan ABDULLAYEVA2, Hamid PIRIYEV3, Azerbaijan State Oil and Industry University ORCID: 2. 0000-0003-0168-9623; 3. 0009-0000-2992-6358 Abstract. In today’s world, when the role of renewable energy sources is becoming increasingly important in the context of combating climate change and reducing dependence on fossil fuels, wind energy occupies a leading position. Wind turbinesContinue reading “Analysis of Electrical Generators for Wind Electric Installations”
A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks
Published by Jalal Ibrahimov1, Tural Aliyev2, Ilkin Marufov3, Nijat Mammadov4, Azerbaijan State Oil and Industry University ORCID: 3. 0000-0002-3143-0113; 4. 0000-0001-6555-3632 Abstract. The widespread use of electric automobiles will lead to significant changes in instantaneous consumption values and the mechanisms that govern this consumption. Electricity demand will increase sharply and there will be fluctuations inContinue reading “A Solution to Renewable Energy Source Integration Challenges: Integrating Electric Vehicles into Distribution Networks”
Testing of a Micro Hydro Power Plant Using a Cross-Flow Type Turbine
Published by Sri SUWASTI, Musrady MULYADI, Yiyin KLISTAFANI, Muhammad Ruswandi DJALAL, State Polytechnic of Ujung Pandang Abstract: The implementation of Micro Hydro Power Plants (MHPP) serves as a crucial initiative to address the uneven distribution of electrical energy in remote areas across Indonesia. Before the permanent installation of an MHPP, field testing is imperative, involvingContinue reading “Testing of a Micro Hydro Power Plant Using a Cross-Flow Type Turbine”
Blockchain Technology in Electromobility and Electrification of Transport
Published by Anna ZIELIŃSKA, AGH University of Science and Technology, Faculty of Management Abstract: The article describes the possibilities of using blockchain technology in the electromobility sector and in various areas of the autonomous vehicle sector. The aim of the article is to present the dynamics of the development of blockchain technology in markets suchContinue reading “Blockchain Technology in Electromobility and Electrification of Transport”
Power Flow Analysis of Distributed Generation and Distributed Storage (DGDC) in DC Microgrid Using Newton Raphson Method
Published by Machmud Effendy1, Dandy Dwi Saputra1,Fourys Yudo Setiawan Paisey2,Department of Electrical Engineering,University of Muhammadiyah Malang, Indonesia (1)Department of Electrical Engineering, University of Papua Manokwari, Indonesia (2) Abstract. Centralized generation centralized storage architecture (CGCSA) and distributed generation distributed storage architecture (DGDSA) are two operation of the proposed scheme, both architectures are evaluated at different distributionContinue reading “Power Flow Analysis of Distributed Generation and Distributed Storage (DGDC) in DC Microgrid Using Newton Raphson Method”
Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources
Published by Ruchika, D.K. Jain, DCRUST, Murthal, Haryana Abstract. Battery energy storage system (BESS) plays a dominant role in large scale penetration of renewable energy sources into the grid. They help in a better match between the demand- supply during standalone mode and the grid connected mode. In this paper, the authors proposed a newContinue reading “Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources”
Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems
Published by 1. Piotr GRYGIEL1,2, 2. Jan TARŁOWSKI2, 3. Krzysztof MIK3, Gdańsk University of Technology (1), Xdisc S.A.,Warsaw, Poland (2), Energy Conversion and Renewable Resources Research Centre, Polish Academy of Sciences, (3) ORCID: 1. 0000-0003-2769-9088; 3. 0000-0002-9510-3066 Abstract. Two types of full-size photovoltaic modules for on-grid systems with maximum DC voltage of 600 V haveContinue reading “Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems”
Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey
Published by 1. Lenin Babu Chilakapati, 2. T Gowri Manohar, SVU College of Engineering, Sri Venkateswara University. ORCID: 1.0000-0001-9749-979X; 2.0000-0003-0441-6022 Abstract. Renewable energy technologies are becoming more and more common for generating electricity because they are environmentally friendly and can meet local electricity needs. They reduce network congestion and also lighten the load on conventionalContinue reading “Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey”