Published by Machmud Effendy1, Dandy Dwi Saputra1,Fourys Yudo Setiawan Paisey2,Department of Electrical Engineering,University of Muhammadiyah Malang, Indonesia (1)Department of Electrical Engineering, University of Papua Manokwari, Indonesia (2) Abstract. Centralized generation centralized storage architecture (CGCSA) and distributed generation distributed storage architecture (DGDSA) are two operation of the proposed scheme, both architectures are evaluated at different distributionContinue reading “Power Flow Analysis of Distributed Generation and Distributed Storage (DGDC) in DC Microgrid Using Newton Raphson Method”
Tag Archives: Smart / Microgrids
Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources
Published by Ruchika, D.K. Jain, DCRUST, Murthal, Haryana Abstract. Battery energy storage system (BESS) plays a dominant role in large scale penetration of renewable energy sources into the grid. They help in a better match between the demand- supply during standalone mode and the grid connected mode. In this paper, the authors proposed a newContinue reading “Battery Energy Storage System for Large Scale Penetration of Renewable Energy Sources”
Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems
Published by 1. Piotr GRYGIEL1,2, 2. Jan TARŁOWSKI2, 3. Krzysztof MIK3, Gdańsk University of Technology (1), Xdisc S.A.,Warsaw, Poland (2), Energy Conversion and Renewable Resources Research Centre, Polish Academy of Sciences, (3) ORCID: 1. 0000-0003-2769-9088; 3. 0000-0002-9510-3066 Abstract. Two types of full-size photovoltaic modules for on-grid systems with maximum DC voltage of 600 V haveContinue reading “Commercial Lightweight Photovoltaic Modules for Applications in On-Grid Systems”
Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey
Published by 1. Lenin Babu Chilakapati, 2. T Gowri Manohar, SVU College of Engineering, Sri Venkateswara University. ORCID: 1.0000-0001-9749-979X; 2.0000-0003-0441-6022 Abstract. Renewable energy technologies are becoming more and more common for generating electricity because they are environmentally friendly and can meet local electricity needs. They reduce network congestion and also lighten the load on conventionalContinue reading “Microgrid Power Quality Enhancement with Adaptive Control Strategies: A Literature Survey”
Renewable Energy Collector Transformers
Published by 1. Waldemar ZIOMEK, 2. Krishnamurthy VIJAYAN, PTI Transformers LP, Winnipeg, MB, Canada ORCID: 1. 0000-0002-1216-6513 Abstract. The renewable energy collector transformer (RCT) in a solar station, or a wind farm, transforms the voltage from the collector system to the transmission level voltages. As the primary goal is stepping up the voltage, the RCTContinue reading “Renewable Energy Collector Transformers”
Protection of DC Microgrid using ΔCB
Published by 1. Marwan R. Abed, 2. Oday A. Ahmed, 3. Ghassan A. Bilal, University of Technology Iraq, Baghdad, ORCID: 1. 0000-0002-1257-2810; 2. 0000-0001-7214-3412; 3. 0000-0002-5090-103X Abstract. When implementing a DC distribution network, it is much easier to integrate distributed energy sources than it is with an ac grid. Furthermore, the efficiency and reliability ofContinue reading “Protection of DC Microgrid using ΔCB”
Adaptive Control for Power Management Based on Renewable Energy
Published by Mahmood T. Alkhayyat1, Laith A. Khalaf2, Mohammed Y. Suliman3, Northern Technical University. ORCID: 1. 0000-0001-6119-7845; 2. 0000-0003-1602-6152; 3. 0000-0002-1250-6362 Abstract. A special form of energy system that can be utilized to provide all the energy needed in the globe is the renewable hybrid system. In order to successfully use renewable energy and decreaseContinue reading “Adaptive Control for Power Management Based on Renewable Energy”
Fiber Optic Technology for Pressure Measurements in High Voltage Switchgear
Published by 1. Damian KOSTYŁA1, 2. Paweł WĘGIEREK1, 3. Michał LECH1,Lublin University of Technology, Faculty of Electrical Engineering and Computer Science (1)ORCID: 1. 0000-0002-9012-0158; 2. 0000-0002-0812-3414; 3. 0000-0002-4732-2459 Abstract. The paper presents a review of traditional and fiber optic methods dedicated to pressure measurement in the context of ongoing research work on the development ofContinue reading “Fiber Optic Technology for Pressure Measurements in High Voltage Switchgear”
Communication Research of Protective Relays for Microgrids and Active Distribution Networks
Published by 1. Róbert Štefko1, Zsolt Čonka1, Michal Kolcun, 2. Viktor Jurák2, 3. Judith Pálfi3, Technical University of Košice (1), Brno University of Technology (2), Óbuda University (3) ORCID: 1. 0000-0002-2477-4559, 0000-0001-6620-4354, 0000-0002-8041-9076; 2. 0000-0002-6832-7654 Abstract. The penetration of renewable energy sources into the electricity distribution network causes changes in power flows, making conventional protectionContinue reading “Communication Research of Protective Relays for Microgrids and Active Distribution Networks”
Design PV Power System: A Case Between Two Different Types of Solar Modules
Published by 1. Ali N. Hamoodi1, 2. Waseem Kh. Ibrahim2, 3. Aseel Thamer Ebrahem3, Northern Technical University (1), Northern Technical University (2), Northern Technical University (3)ORCID: 1. 0000-0003-0991-3538; 2. 0000-0002-9126-7872; 3. 0000-0002-1090-0454 Abstract. A photovoltaic (PV) is a technical terminology that is used to generate electricity from sunlight. Solar energy is one of the solutionsContinue reading “Design PV Power System: A Case Between Two Different Types of Solar Modules”