Published by Paweł PIJARSKI, Sylwester ADAMEK, Robert JĘDRYCHOWSKI, Klara SEREJA, Lublin University of Technology, Department of Electrical Networks and Security Abstract. An increasing number of connected prosumer installations, mainly photovoltaic ones, can cause problems with the operation of lowvoltage networks such as voltage fluctuations. These problems can be solved by an adequate control of theContinue reading “Monitoring the Impact of Prosumer Micro Installations on the Electrical Parameters of Low-Voltage Network Systems”
Tag Archives: Smart / Microgrids
Control System for Distributed Generation in Low Voltage Network Systems
Published by Robert JĘDRYCHOWSKI, Klara SEREJA, Politechnika Lubelska, Katedra Sieci Elektrycznych i Zabezpieczeń, Poland Abstract. Implementation of prosumer energy generation to low-voltage network systems involves both benefits and technological problems concerning the grid operation. Electricity generation in LV network systems is of a distributed and quite unpredictable character. In those systems, solar PV installations, whoseContinue reading “Control System for Distributed Generation in Low Voltage Network Systems”
The use of Power Restoration Systems for Automation of Medium Voltage Distribution Grid
Published by Michał KONARSKI, Paweł WĘGIEREK, Lublin University of Technology, Faculty of Electrical Engineering and Computer Science, Lublin, Poland Abstract. The article presents assumptions, characteristics and conclusions of functional tests of a pilot implementation of a power restoration system in one of the Distribution System Operators. The main objective of conducted and described tests wasContinue reading “The use of Power Restoration Systems for Automation of Medium Voltage Distribution Grid”
Low-Cost and Accuracy Smart Meter Prototype for Smart Grids
Published by 1. Rafael GIVANILDO, 2. Denis LIMA, 3. Paulo PARIS, 4. Emerson PEDRINODepartment of Computer Science, Federal University of Sao Carlos, Sao Carlos, Brazil ORCID: 1. 0000-0003-1372-6049, 2. 0000-0002-0457-2562, 3. 0000-0001-8915-8215, 4. 0000-0003-3734-3202 Abstract. This article aims to carry out a brief bibliographical review on the main concepts related to Smart Grid, in additionContinue reading “Low-Cost and Accuracy Smart Meter Prototype for Smart Grids”
Chargers for Electric Cars with V2G (Vehicle to Grid) Technology – Connection Principles for the Distribution Network
Published by Joanna BARANIAK, Jacek STARZYŃSKI Warsaw University of Technology, Institute of Theory of Electrical Engineering, Measurement and Information Systems Abstract. Electric vehicles will be an integral part of the smart grid in the future. The chargers that come with the V2G (vehicle to grid) service provide bidirectional electrical energy flow between the cars andContinue reading “Chargers for Electric Cars with V2G (Vehicle to Grid) Technology – Connection Principles for the Distribution Network”
An Introduction to Microgrid Energy Management Systems
Published by Anushree Ramanath, EE Power – Technical Articles: An Introduction to Microgrid Energy Management Systems, July 05, 2021. This article highlights the growth of microgrids and the components of these systems. With the growing number of industries and businesses, access to reliable and cost-effective power is critical. This leads to demand for small-scale powerContinue reading “An Introduction to Microgrid Energy Management Systems”
Microgrid Operations and Applications
Published by Anushree Ramanath, EE Power – Technical Articles: Microgrid Operations and Applications, August 01, 2021. In this article, we’ll learn about microgrids, their operations, and applications in electrical utilities and various organizations. Today’s world relies on an uninterrupted electricity supply. A microgrid is a local energy grid with the capability of controlling its components [1].Continue reading “Microgrid Operations and Applications”
Model of Smart Electricity Meter
Published by Marek PAWŁOWSKI, Piotr BORKOWSKI, Bartosz BALSAM, Lodz University of Technology, Department of Electrical Apparatus Abstract. This paper presents the concepts of smart electricity grids with particular emphasis on aspects of the metering of customers through the implementation of smart meters. On the basis of the literature study, an analysis of the scope ofContinue reading “Model of Smart Electricity Meter”
Active Consumers in Smart Grid Systems – Applications of the Building Automation Technologies
Published by Marian NOGA1, Andrzej OŻADOWICZ1, Jakub GRELA1, Grzegorz HAYDUK1, AGH Akademia Górniczo-Hutnicza, Wydział Elektrotechniki, Automatyki, Informatyki i Inżynierii Biomedycznej (1) Abstract. The Building Automation Systems (BAS) fulfil an increasingly important role in buildings, especially commercial and public buildings. They are an essential element of the building management systems (BMS) organization, integrating all building infrastructureContinue reading “Active Consumers in Smart Grid Systems – Applications of the Building Automation Technologies”
A Literature Survey on the Applications of Internet of Things
Published by B. Mary Havilah Haque1, 2. D. Jackuline Moni2, 3. D. Gracia31,2Karunya Institute of Technology and Sciences, Coimbatore, Tamilnadu, India3Sri Ramakrishna Engineering College, Coimbatore, Tamilnadu, IndiaORCID. 1. 0000-0002-9077-7395, 2. 0000-0001-7314-023X, 3. 0002-4550-1445 Abstract. Internet of Things can ensure easy and comfortable life of the human. This present era is mostly digitized and appliances canContinue reading “A Literature Survey on the Applications of Internet of Things”