Published by Liu Liqun, Liu Chunxia*, Taiyuan University of Science & Technology Abstract. At present, an optimal maximum power tracking (MPPT) and grid-connected control methods for a PV power system are very important to improve the output efficiency. However, most of literatures only introduce the MPPT or PLL method, respectively. A novel MPPT method isContinue reading “A Grid-Connected PV Power System Total Considers the MPPT and SSRF-SPLL Control Technologies”
Tag Archives: PV Systems
Power Quality Analysis of Grid-Connected Photovoltaic Systems in Distribution Networks
Published by Masoud FARHOODNEA1, Azah MOHAMED1, Hussain SHAREEF1, Hadi ZAYANDEHROODI1, University Kebangsaan Malaysia (UKM) (1) Abstract. This paper presents a dynamic PQ analysis on the effects of high-penetrated grid-connected photovoltaic (PV) systems in a distribution system under different weather conditions. To track practical considerations, all information on PV units and weather conditions given in thisContinue reading “Power Quality Analysis of Grid-Connected Photovoltaic Systems in Distribution Networks”
Feasibility Analyses of Hybrid Wind-PV-Battery Power System in Dongwangsha, Shanghai
Published by Liu Liqun, Liu Chunxia, Taiyuan University of Science & Technology Abstract. This paper gives the feasibility analysis of a wind-PV-battery system for an off-grid power station specially located in remote village of Dongwangsha, Shanghai. The simulation and optimization results indicated the feasibility analyses of the proposed hybrid wind-PV system with storage battery backup.Continue reading “Feasibility Analyses of Hybrid Wind-PV-Battery Power System in Dongwangsha, Shanghai”
Roof Integrated Grid Connected PV Systems Capacity in Gran Canaria Island
Published by Norberto ANGULO1, Antonio PULIDO1, Felipe DÍAZ1, Fabián DÉNIZ1, Expedito SÁNCHEZ1, Rafael SÁNCHEZ2, Universidad de Las Palmas de Gran Canaria (1), Mancomunidad del Sureste de Gran Canaria (2) Abstract. The main aim of this paper is to determine the photovoltaic capacity of Gran Canaria Island, part of the Canary Islands, an archipelago with highContinue reading “Roof Integrated Grid Connected PV Systems Capacity in Gran Canaria Island”
Dranetz Encore System monitoring BNL/BP Solar Photovoltaic (PV) Plant
Interconnection Standards in North America
Published by Thomas Key, EPRI, Senior Technical Executive. November 21st 2014
Power Quality Measurements Near DER and Disturbing Loads
Published by Ir. M. van Lumig, Electrical Power Systems, Analysis and Concepts Laborelec NL Beek-Maastricht Airport, the Netherlands, e-mail: michiel.vanlumig@laborelec.com Ir. S. Bhattacharyya, Electrical Energy Systems Group Technical University Eindhoven Eindhoven, the Netherlands, e-mail: s.bhattacharyya@tue.nl Dr. ir. J.F.G. Cobben, Electrical Energy Systems Group Technical University Eindhoven Eindhoven, the Netherlands Prof.ir. W.L. Kling, Electrical Energy SystemsContinue reading “Power Quality Measurements Near DER and Disturbing Loads”
Technical Design Specifications and Criteria for Integrating PV Systems into Distribution Networks in Egypt
Published by Omar H. Abdalla, Fellow Egyptian Society of Engineers, Life Senior Member IEEE. Prof. O. H. Abdalla is with the Department of Electrical Power and Machines Engineering, Faculty of Engineering, 1 Sherief Street, P.O. Technology, P.C. 11792, Helwan, Cairo, Egypt. (e-mail: ohabdalla@ieee.org). Conference Paper: Keynote Lecture (KL-REN-5), International Conference on New Energy and EnvironmentalContinue reading “Technical Design Specifications and Criteria for Integrating PV Systems into Distribution Networks in Egypt”