Chargers for Electric Cars with V2G (Vehicle to Grid) Technology – Connection Principles for the Distribution Network

Published by Joanna BARANIAK, Jacek STARZYŃSKI Warsaw University of Technology, Institute of Theory of Electrical Engineering, Measurement and Information Systems Abstract. Electric vehicles will be an integral part of the smart grid in the future. The chargers that come with the V2G (vehicle to grid) service provide bidirectional electrical energy flow between the cars andContinue reading “Chargers for Electric Cars with V2G (Vehicle to Grid) Technology – Connection Principles for the Distribution Network”

Electric Power System of Tu-154M Passenger Aircraft

Published by Jacek F. GIERAS, University of Technology and Life Sciences, Bydgoszcz Abstract. The paper discusses the electric power system of the Tu-154M aircraft. After brief introduction to aircraft power systems, the results of reverse design and analysis of the GT40PCh6 wound-field synchronous generator including short circuit have been presented. Electric power distribution and assignmentContinue reading “Electric Power System of Tu-154M Passenger Aircraft”

Grounding and Bonding — New Questions and Answers

Published by Ark Tsisserev, International Association of Electrical Inspectors (IAEI) Magazine, Canadian Perspectives – Grounding and Bonding — New Questions and Answers, July 1, 2021 Although Section 10 of the Canadian Electrical Code, Part I (CE Code), which applies to grounding and bonding, has been re-written in the 2018 edition of the Code, I keep receivingContinue reading “Grounding and Bonding — New Questions and Answers”

Current-Carrying Capacity Parallel Single-Core LV Cable

Published by Lech BOROWIK1, Artur CYWIŃSKI2Politechnika Częstochowska, Wydział Elektryczny (1), Pracownia Projektowa omega-projekt (2) Abstract. The paper presents the problems related to the selection of parallel single-core low voltage cables in terms of their current carrying capacity and accordance with PN-IEC 60364-5-523 national standard, exemplified by electric power transmission from transformer MV/LV 1600kVA, with proximityContinue reading “Current-Carrying Capacity Parallel Single-Core LV Cable”

The Measurement of Input Power of Power Supply in Network Disturbed by Low Frequency Distortions

Published by Stanisław GALLA, Arkadiusz SZEWCZYK,Gdansk University of Technology Faculty of Electronics, Telecommunications and Informatics Abstract. In the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elementsContinue reading “The Measurement of Input Power of Power Supply in Network Disturbed by Low Frequency Distortions”

Method of Selecting the Most Important Power Lines in a Transmission and Distribution Network

Published by Dalibor VALEK, Radomir SCUREK, Technical University of Ostrava, Faculty of Safety Engineering Abstract: This article describes the method used to graph theory in security analysis. For the pursposes of this study, an environment is referred to here as a network of power lines and devices and a power grid is considered as aContinue reading “Method of Selecting the Most Important Power Lines in a Transmission and Distribution Network”

Transmission System Harmonics Study

Published by Electrotek Concepts, Inc., PQSoft Case Study: Transmission System Harmonics Study, Document ID: PQS0501, Date: March 31, 2005. Abstract: A utility presently operates two 16.8 MVAr capacitor banks in a 161/69kV substation. Supplied by this substation are residential, commercial, and industrial loads, including a steel manufacturing facility. For increased voltage support, the utility is investigatingContinue reading “Transmission System Harmonics Study”

Case Study on Fault Analysis Using PMU

Published by Prithwish Mukhopadhyay, General Manager, prithwish.mukhopadhyay@posoco.in,Rajkumar Anumasula, Senior Engineer, rajkumar@posoco.in, Abhimanyu Gartia, Deputy General Manager, agartia@posoco.in, Chandan Kumar, Engineer, chandan.wrldc@posoco.in, Pushpa Seshadri, Chief Manager, pushpa_seshadri@posoco.in, Sunil Patil, Engineer, skpatil@posoco.in , WRLDC, Mumbai, India Abstract — Synchrophasors are used extensively in Indian Grid to detect and analyze faults occurring in the system. This paper majorlyContinue reading “Case Study on Fault Analysis Using PMU”

An Introduction to Microgrid Energy Management Systems

Published by Anushree Ramanath, EE Power – Technical Articles: An Introduction to Microgrid Energy Management Systems, July 05, 2021. This article highlights the growth of microgrids and the components of these systems. With the growing number of industries and businesses, access to reliable and cost-effective power is critical. This leads to demand for small-scale powerContinue reading “An Introduction to Microgrid Energy Management Systems”

Harmonics Standards

Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Harmonics standards Harmonic emissions are subject to various standards and regulations: • Compatibility standards for distribution networks• Emissions standards applying to the equipment causing harmonics• Recommendations issued by Utilities and applicable to installations In view of rapidly attenuating the effects of harmonics, a tripleContinue reading “Harmonics Standards”